Bil, MERCEDES, G 463, 463.274 Mercedes-AMG G 65, Mercedes-AMG G 650 Landaulet, M279 - ME1778 (ME)

M279 - ME1778 (ME) - 0

Identifikation

Diagnose version: 00 2B 24

Boot software number: 0.0.0

Hardwareversion: 0.0.0

Softwareversion: 0.0.0

Software version 1: --

Software version 2: --

Supplier: --

Hardware vare nummer:

Software part number (customer): --

Software part number (code): --

Software part number (data): --

Serie nummer: --

Stel nr.:

VIN stored:

Fejlkoder

P010000: Mass or volume air flow (MAF) sensor 1/A - electrical fault

Controls

Clear DTC

Levende Data

Motor Hastighed: 0 Omdr.

Batteri spænding: 0.0 V

Kølemiddeltemperatur: -48.0 °C

Indsugningslufttemperatur: -48.00 °C

Oil level: 0.1 mm

Oil temperature: -273.15 mm

Oil quality: 1

Fuel tank level: 0 L

Engine speed (specified): 0 Omdr.

Indsugningsmanifoldtryk: 0 hPa

Gasspjælds positions føler: 0 °

Indsprøjtnings tid B1: 0.00 ms

Indsprøjtnings tid B2: 0.00 ms

Purging switchover valve: 0.00 %

Idle speed: Nej

Gear engaged: P-N

Indsugningslufttemperatur: -48.00 °C

Ladetrykføler: 0.0 hPa

Pressure sensor downstream of air cleaner bank 1: 0.00 hPa

Pressure sensor downstream of air cleaner bank 2: 0.00 hPa

Outside pressure sensor: 0 hPa

Lambda 1 control bank 1: 0.000

Lambda 1 control bank 2: 0.000

Lambda 1 control bank 1: --

Lambda 1 control bank 2: Sluk

O2 sensor 1, bank 1 is operational: Nej

O2 sensor 1, bank 2 is operational: Nej

Lambda 2 control bank 1: 0.000

Lambda 2 control bank 2: 0.000

O2 sensor 2, bank 1 is operational: Nej

O2 sensor 2, bank 2 is operational: Nej

Exhaust gas temperature sensor 2, bank 1: -273.15 °C

Exhaust gas temperature sensor 2, bank 2: -273.15 °C

Belastning Motor: 0 %

Boost pressure positioner - duty cycle: 0 %

Deceleration air switchover valve: Lukket

Deceleration brændstoflukning: Nej

Full load: Nej

Transmission protection: Ikke aktiv

Knock control: Nej

Knock sensor noise: Nej

Charge air cooler circulation pump: Sluk

Pressure sensor downstream of air cleaner bank 1: 0.00 hPa

Pressure sensor downstream of air cleaner bank 1: 0.00 V

Pressure sensor downstream of air cleaner bank 2: 0.00 hPa

Pressure sensor downstream of air cleaner bank 2: 0.00 V

Boost pressure (raw value): 0.00 V

Boost pressure adaption correction factor: 0.00 V

Misfire cylinder 1: 0.00

Misfire cylinder 2: 0.00

Misfire cylinder 3: 0.00

Misfire cylinder 4: 0.00

Misfire cylinder 5: 0.00

Misfire cylinder 6: 0.00

Misfire cylinder 7: 0.00

Misfire cylinder 8: 0.00

Misfire cylinder 9: 0.00

Misfire cylinder 10: 0.00

Misfire cylinder 11: 0.00

Misfire cylinder 12: 0.00

Smooth running of cylinder 1: 0.00

Smooth running of cylinder 2: 0.00

Smooth running of cylinder 3: 0.00

Smooth running of cylinder 4: 0.00

Smooth running of cylinder 5: 0.00

Smooth running of cylinder 6: 0.00

Smooth running of cylinder 7: 0.00

Smooth running of cylinder 8: 0.00

Smooth running of cylinder 9: 0.00

Smooth running of cylinder 10: 0.00

Smooth running of cylinder 11: 0.00

Smooth running of cylinder 12: 0.00

Accelerator pedal: 0.0 V

Speeder pedal positions føler N1: 0.00 V

Speeder pedal position N2: 0.00 V

Kickdown recognition: Nej

Gaspedalposition: 0 %

Throttle valve position 1: 0.00 V

Throttle valve position 2: 0.00 V

Generator ID: 0 V

Circuit 61: Nej

Calculated generator torque: 0.0000 kNm

Generator electrical fault: Nej

Generator mechanical fault: Nej

Fan capacity request by air conditioning: 0 %

Fan run-on: Ikke aktiv

Fan power effective on/off ratio: -- %

Self-adaptation in idle speed range, bank 1 of cylinders: 0.00 %

Self-adaptation in idle speed range, bank 2 of cylinders: 0.00 %

Self-adaptation in upper partial-load range, bank 1 of cylinders: 0.00

Self-adaptation in upper partial-load range, bank 2 of cylinders: 0.00

Ambient temperature: -48.00 °C

Heating system shutoff valve: Åben

Rear air conditioner: 0

Air conditioning status: Nej

Motor kølevæske temperatur føler: 0.00 V

Correction factor for fan run-on time: 0 %

Engine temperature (specified value): 0.00 °C

Control module temperature: -48.00 °C

Brændstofpumpe: Nej

Activated charcoal canister shut off valve: Lukket

Electric air pump: Sluk

Air pump switchover valve bank 1: Lukket

Fuel pump permanently on: Ikke aktiveret

Throttle valve adaptation status test conditions: --

Udgangs test

Controls

Fuel pump

Engine/AC electric suction fan

Throttle valve actuator

Charge air cooler circulation pump

Purging switchover valve

Boost pressure actuator

Electric air pump

Air pump 1 switchover valve

Air pump 2 switchover valve

Deceleration air switchover valve

indsprøjtnings dyser

Muligheder

Controls

Correction programming of ignition

Fuel pump activation

Teaching process of throttle valve stop

Reset adaptation values

Enabling of engine start after crash event

Rediger stel nr.

Konfiguration

Controls

Redigere konfiguration

Explicit coding