Bil, CITROEN, C4 (B7), 9HP - EDC17C10 BR2
9HP - EDC17C10 BR2 - 0
Identifikation
PSA reference: 96 66 07 72 80
ECU manufacturer: Bosch
Additional number: 96 66 72 95 80
Softwareversion: DE 02
Software reference: 67 24 72
Stel nr.: VF7SC9HPKDW638142
Motortype: 9HP
Model: C3 A51
Fejlkoder
P0693: Engine cooling fan motor 2 - circuit open or short to battery
Controls
Clear DTC
Levende Data
Vehicle speed limit: Ikke aktiv
Electric parking brake: Potentially crossed over
Uncorrected coolant temperature: -40 °C
Uncorrected air temperature: 125 °C
Generator temperature: 76 °C
Batteritemperatur: 46 °C
Generator voltage: 2.61 V
Battery charge: 14.99 V
Battery charging: 25 %
Generator speed: 1200 Omdr.
Predicted reversible generator torque reference value: 47 N·m
Torque necessary for restarting: 43 N·m
Actual torque of reversible generator: 94 N·m
Stop/start: Nedtrykket
Condition of neutral sensor: FALSK
Power accumulator replacement reset: Aktiv
ECO mode: Aktiv
Status of request for resetting of power storage battery: Aktiv
Driver present: Tilstede
Generator deactivation: Inaktiv
Reverse gear engaged: Ja
Koblingspedalpositionsføler: 0 %
Stop and start function: Load shedding generator
Stop authorised by the power steering ECU: Ja
Stop authorised by the ECUs for the suspension and wheels: Ja
Stop authorised by the engine subsystem: Ja
Stop authorised by the voltage retaining device ECU: Ja
Stop authorised by the BSI ECU: Nej
Stop authorised by the transaxle ECU: Nej
Request for restarting sent by the power steering ECU: Ja
Request for restarting sent by the ECUs for the suspension and wheels: Ja
Request for restarting sent by the voltage retaining device ECU: Ja
Request for restarting sent by the BSI ECU: Ja
Vacuum available in the braking circuit: Ja
Status of the drive train: Åben
Gearvælgerstilling: Ugyldig
Batteritemperatur: 104 °C
Temperature of power electronics of the voltage retaining device: 48 °C
Vacuum in the vacuum circuit: 188 mbar
Reversible generator status: Pre-flow mode
Authorisation of restarting received by the engine ECU via the LIN: Nej
Authorisation of restarting sent by the engine ECU to the reversible generator: Nej
Reversible generator reference: Cutting-out aid
Status of the voltage retaining device: Faulty
Nominal state of health of the power accumulato: Nej
Voltage at terminals of the power accumulator: 4.75 V
Status of the voltage retaining device: Overheating
State of health of the power accumulator: 80 %
Ancillary drive belt replacement required: Ja
Cause of engine not stopping: No cause of not stopping stored; No cause of not stopping stored; No power steering stopping authorisation; No cause of not stopping stored; No cause of not stopping stored; No cause of not stopping stored; No cause of not stopping stored; No cause of not stopping stored
Electrical cause of engine not stopping: Stop and Start anticipation alert; No cause of not stopping stored; No cause of not stopping stored; No cause of not stopping stored; No cause of not stopping stored; ; ;
Engine restartability guaranteed by the reversible generator: Restartability not guaranteed
Convergence of state of health of the power accumulator: Non-converged state of health
Reversible generator restart authorisation: Nej
Reversible generator stop authorisation: Ja
Reversible generator restart order: Ja
Voltage retaining device ECU restart authorisation: Ja
Suspension and wheels ECUs restart authorisation: Ja
Camshaft and crankshaft synchronization: Ja
Last initialisation value for the air mixer: Done
Status of last learning of EGR valve: Done
Last turbo initialisation: Done
Initialised initial position of EGR valve lower limit: 10 %
Last initialised position of EGR valve lower limit: 10 %
Initialised initial position of the air mixer upper limit: 160 %
Initialised initial position of the air mixer lower limit: 50 %
Last initialised position of the air mixer upper limit: 104 %
Last initialised position of the air mixer lower limit: 50 %
Initialised initial position of the turbo upper limit: 60 %
Initialised initial position of the turbo lower limit: 22 %
Last initialised position of turbo upper limit: 90 %
Last initialised position of turbo lower limit: 23 %
Motor Hastighed: 380.8 Omdr.
Fuel flow regulator: 19 %
Fuel pressure instructions: 175 bar
Fuel pressure measured: 51 bar
Calculated injected flow: 3.5 mg/impulse
Injector 1 correction value: 2.1 mg/impulse
Injector 2 correction value: 3.0 mg/impulse
Injector 3 correction value: 3.2 mm³/stk
Injector 4 correction value: 1.4 mm³/stk
Brændstoftemperaturføler: 108 °C
Injector opening correction strategies activation status: Inaktiv
Injection time cylinder 1: 1.5 ms
Injection time cylinder 2: 0.5 ms
Injection time cylinder 3: 0.2 ms
Injection time cylinder 4: 1.7 ms
High pressure fuel pump: 607.8 mA
Fuel rail pressure reference value: No limitation
Air flow sensor: -50 °C
Intake air temperature sensor: -50 °C
Turbo pressure: 0 mbar
Measured turbo pressure: 18 mbar
Barometrisk tryk føler: 0 mbar
Turbo position reference value: 0 %
Turbo position repeat: 0 %
Air metering valve position copy: 0 %
Air metering valve position setting: 0 %
EGR-ventil, position: 0 %
EGR valve position repeat: 0 %
EGR valve open cycle ratio: -100.0 %
EGR exchanger bypass position reference value: 0 %
Outside air temperature: -50 °C
Turbo pressure duty cycle: 0 %
Target mass air flow: 0 mg/impulse
Luft masse måler: 0 mg/impulse
Mixture calculated by the O2 sensor: 0.000
Activation heating O2 sensor: 2 %
Diesel Particulate filter (DPF) soot mass: 4.045 g/l
Diesel Particulate filter (DPF) cinder count: 26 %
Diesel Particulate filter (DPF) distance before replacing: 75424 km
Diesel Particulate filter (DPF) differential pressure: 5 mbar
Quantity of additive deposited in the filter: 35 g
Diesel Particulate filter (DPF) outlet temperature: 16 °C
Authorisation of regeneration: Nej
Additive minimum level: Not reached
Exhaust heat recovery: Inaktiv
Diesel Particulate filter (DPF) regeneration status: Aktiv
Power consuming equipment activation request: Ja
Diesel Particulate filter (DPF) distance since last regeneration: 226 km
Average distance between the last 10 regenerations: 224 km
Diesel Particulate filter (DPF) distance since last changed: 83368 km
Køretøjets hastighed sensor: 18 km/h
Status for fartpilotsystem: Aktiv
Clutch pedal: Nedtrykket
Hastighedsbegrænser: Aktiv
Main brake information: Udløst
Brake pedal redundant: Nedtrykket
Accelerator pedal point of resistance sensor: Not exceeded
Speeder pedal positions føler N1: 400 mV
Speeder pedal position N2: 200 mV
Accelerator pedal position sensor: 22 %
Gear transmission ratio: Bakning
Gearbox type: Automatisk
Cruise control speed setting: 23 km/h
Cruise control speed setting: 22 km/h
Generator charge information: 4250 ms
Batteri spænding: 13.40 V
Temperature controlled generator: 10 °C
Power relay: Aktiv
Additional heating: Aktiv
Clutch pedal: 17 %
Starting inhibiting control (information filaire): Prohibited
Starting inhibiting control (multiplexed information): Authorised
Motor kølevæske temperatur føler: 60 °C
Cooling fan reference speed: 0 %
Køleventilatorhastighed: 0 %
Køleventilatorrelæ 2: Not control
A/C circuit pressure: 5.7 bar
Oil pressure: OK
Oil level: 762 mV
Motor status: Autonomous starting
DPF information
Air flow sensor: -50 °C
Intake air temperature sensor: -50 °C
Turbo pressure: 0 mbar
Measured turbo pressure: 18 mbar
Barometrisk tryk føler: 0 mbar
Turbo position reference value: 0 %
Turbo position repeat: 0 %
Air metering valve position copy: 0 %
Air metering valve position setting: 0 %
EGR-ventil, position: 0 %
EGR valve position repeat: 0 %
EGR valve open cycle ratio: -100.0 %
EGR exchanger bypass position reference value: 0 %
Outside air temperature: -50 °C
Turbo pressure duty cycle: 0 %
Target mass air flow: 0 mg/impulse
Luft masse måler: 0 mg/impulse
Motor Hastighed: 256.0 Omdr.
Mixture calculated by the O2 sensor: 0.000
Activation heating O2 sensor: 2 %
Diesel Particulate filter (DPF) soot mass: 4.045 g/l
Diesel Particulate filter (DPF) cinder count: 26 %
Diesel Particulate filter (DPF) distance before replacing: 75424 km
Diesel Particulate filter (DPF) differential pressure: 5 mbar
Additive tank: 1020 ml
Volume of additive remaining in the reservoir: 581 ml
Quantity of additive deposited in the filter: 35 g
Diesel Particulate filter (DPF) outlet temperature: 16 °C
Authorisation of regeneration: Nej
Additive minimum level: Not reached
Diesel Particulate filter (DPF) regeneration status: Aktiv
Power consuming equipment activation request: Ja
Diesel Particulate filter (DPF) distance since last regeneration: 226 km
Average distance between the last 10 regenerations: 224 km
Diesel Particulate filter (DPF) distance since last changed: 83368 km
Motor kølevæske temperatur føler: 60 °C
Yderligere information
Cylinder 1 injector code: F7 7F 9B D0
Cylinder 2 injector code: 01 F0 E0 28
Cylinder 3 injector code: 0E 01 C2 18
Cylinder 4 injector code: 0E 23 00 48
Immobilizer
Locking of the ECU: Låst
Statspærrestatus: Matched ECU
Problem detected when transmitting the unlock code: The programming status of the engine immobiliser cannot be read
Current driving (over the last 20 kilometers)
No vehicle stop authorisation: 13
No power steering stopping authorisation: 143
No chassis stop authorisation: 2
Inadequate braking assistance: 201
No engine stop authorisation: 7
No electromotor subassembly stop authorisation: 255
No restart torque stop authorisation: 7
No gearbox stopping authorisation: 7
Driving between last 20 and 40 kilometers
No vehicle stop authorisation: 2
No power steering stopping authorisation: 3
No chassis stop authorisation: 4
Inadequate braking assistance: 5
No engine stop authorisation: 6
No electromotor subassembly stop authorisation: 7
No restart torque stop authorisation: 8
No gearbox stopping authorisation: 9
Driving between last 40 and 60 kilometers
No vehicle stop authorisation: 243
No power steering stopping authorisation: 3
No chassis stop authorisation: 234
Inadequate braking assistance: 66
No engine stop authorisation: 36
No electromotor subassembly stop authorisation: 65
No restart torque stop authorisation: 20
No gearbox stopping authorisation: 20
Udgangs test
Controls
Turbocharger actuator
EGR exchanger bypass
Checking pressurisation of air entering the engine
Checking engine setting
Air flow circulation
EGR circuit checking
Checking the functioning of the air circuit assembly
Tryk i brændstoffordelerrør
Engine compressions test
Manifold inlet pressure sensor checking
Cooling fan high speed
Cooling fan low speed
Fuel flow regulator
EGR-ventil
Pre-post heating relay control
Air mixer
O2 sensor heating
Power supply relay
Additional heating
Additive pump
Muligheder
Controls
Air mixer change
Ancillary drive belt replacement
Cylinder head replacement
DPF regeneration (vehicle stationary)
DPF replacement
EGR exchanger replacement
EGR valve change
Exhaust manifold replacement
Filling of the additive reservoir or pouch
High Pressure pump replacement
Initialization
Injectors replacement
Mass air flow sensor replacement
O2 sensor replacement
Replacement of the diesel additive reservoir, of the pump or of the pipes
Resetting the health condition of the energy accumulator
Turbocharger replacement