Bil, PORSCHE, Cayenne 957 2008-2010, Air conditioning

Klima Anlæg - Air conditioning - 0

Identifikation

Dele nummer: 7L5907040BT

Softwareversion: 4325

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 128452

Software coding: 0001020

System: Klima - SG R/L

Stel nr.: WP1ZZZ9PZ4LA43105

Manufacture location index: @ABC

Production date: 13.06.03

Manufacturer modification status: 111EFGHI

Manufacturer test stand number: K<>4

Manufacturer serial number: 9555

Serie nummer: VWZ3Z0C1073177

Type test number: 11<>222

Flash tool code: 3191266639579

Flash date: 12345678

Hardware assembly: 999

Hardware grades index: VV

Software assembly: DDD

Software grades key: ff

Identificere : 0104

Fejlkoder

0x40C7 [0]: Ukendt fejlkode

0x414C [0]: Ukendt fejlkode

0x4015 [0]: Ukendt fejlkode

Controls

Clear DTC

Levende Data

Central air flap motor stop open: 21.1 ms

Central air flap motor: 340 Omdr.

Target value of central air flap motor: 694 Omdr.

Central air flap motor stop closed: 19.6 %

Side flap motor stop open: 46.2 ms

Side flap motor: 340 Omdr.

Target value of side flap motor: 694 Omdr.

Side flap motor stop closed: 19.6 %

Footwell flap motor stop open: 21.1 ms

Footwell flap motor: 340 Omdr.

Target value of footwell flap motor: 694 Omdr.

Footwell flap motor stop closed: 19.6 %

Temperature flap motor stop open: 68.0 ms

Temperature flap motor: 782 Omdr.

Target value of temperature flap motor: 173 Omdr.

Temperature flap motor stop closed: 6.5 %

Air recirculation flap motor stop open: 31.0 ms

Air recirculation flap motor: 782 Omdr.

Target value of air recirculation flap motor: 173 Omdr.

Air recirculation flap motor stop closed: 19.6 %

Defroster flap stop open: 5.3 ms

Defroster flap motor: 1020 Omdr.

Target value of defroster flap motor: 173 Omdr.

Defroster flap stop closed: 0.4 %

External temperature: 17.0 ms

Internal temperature: 2346 Omdr.

Intake air temperature sensor: 694 Omdr.

A/C refrigerant temperature sensor: 32.6 %

Left front outlet temperature sensor: 17.0 ms

Right front outlet temperature sensor: 340 Omdr.

Left front footwell vent temperature sensor: 694 Omdr.

Right front footwell vent temperature sensor: 6.5 %

A/C compressor shut-off: 85

Hastighed for A/C-kompressor: 0.1 %

A/C compressor load: 340 Omdr.

Fan output reduction: 173 Omdr.

A/C pressure: 51.0 ms

Evaporator temperature sensor: 680 Omdr.

Motor Hastighed: 173 Omdr.

Køretøjs hastighed : 19.6 %

Target value of radiator fan: 347 Omdr.

Radiator fan: 653 Omdr.

Target value of rear window heater: 34.0 ms

Rear window heater: 1360 Omdr.

Target value of front window heater: 173 Omdr.

Front window heater: 6.5 %

Water pump control: 51.0 ms

Residual heat function: 0.1 %

Auxiliary heater control module: 31.0 ms

Ekstra varmer: 1020 Omdr.

Steering wheel heating: 694 Omdr.

Fan: 0.0 %

Front windshield wiper: 694 Omdr.

Target value for front blower control: 5.3 ms

Front blower control: 4600 Omdr.

Speed increase request: 520 Omdr.

Radio key number: 13.1 %

Air recirculation flap required status: 17.0 ms

Luftkvalitetsføler: 2346 Omdr.

Wash/wipe active: 347 Omdr.

Reverse gear: 0.1 %

Left sun sensor light intensity: 17.0 ms

Right sun sensor light intensity: 1020 Omdr.

Terminal 58: 347 Omdr.

Dimmer signal: 0.1 %

Terminal 15: 68.0 ms

Terminal X: 1020 Omdr.

Terminal 30 : 173 Omdr.

Front control unit: 1360 Omdr.

Communication with electrical system module: 347 Omdr.

Communication with accessory gateway: 0.1 %

Communication with rear control unit: 1020 Omdr.

Communication with auxiliary heater module: 694 Omdr.

Grund indstillinger

Controls

Flap motor adaptation

A/C service position

Konfiguration

Controls

Konfiguration

Udgangs test

Controls

Udgangs test