Bil, PEUGEOT, 508, RF
Klima Anlæg - RF - 0
Identifikation
ECU manufacturer: Valeo
Udstyrs nummer: 96 65 96 14 80
Softwareversion: 07 00
Edition calibration: 04 00
Software reference: --
Dele nummer: 00 33 23 52
Stel nr.: VF38D5FEACL008833
Additional number: 96 65 96 14 80
Fejlkoder
U1F0A: CAN fault
Controls
Clear DTC
Levende Data
Right side condition of the sunlight sensor: --
Left side condition of the sunlight sensor: --
Front condition evaporator sensor: --
Passenger compartment air blower: --
Allocation of motor 1: --
Allocation of motor 2: --
Allocation of motor 3: --
Allocation of motor 4: --
Allocation of motor 5: --
Allocation of motor 6: --
Allocation of motor 7: --
Allocation of motor 8: --
Allocation of motor 9: --
Evaporator temperature sensor: 6550.0 °C
Driver side sunlight photo sensor: 96.5 %
Passenger side sunlight photo sensor: 119.5 %
Passenger compartment air blower supply voltage: 11.40 V
Position of the air intake and recirculation motor: 182 %
Left front position mixing motor: 240 %
Right front position mixing motor: 94 %
Left front distribution motor position : 88 %
Right front distribution motor position: 3 %
Levende Data
Right side condition of the sunlight sensor: --
Left side condition of the sunlight sensor: --
Rear evaporator sensor: --
Right rear blown air sensor status: --
Front condition evaporator sensor: --
Left rear blown air sensor status: --
Air quality (concentration of nitrous monoxide NO) sensor: --
Air quality (concentration of carbon monoxide NO) sensor: --
Evaporator temperature sensor: 6550.0 °C
Driver side sunlight photo sensor: 96.5 %
Passenger side sunlight photo sensor: 119.5 %
Air quality sensor value (carbon monoxide: CO): 26.6 %
Air quality sensor value (nitrous oxide: NO): 0.6 %
Left rear blown air temperature: 6548.2 °C
Right rear blown air temperature: 6552.4 °C
Passenger compartment air blower supply voltage: 11.40 V
Position of the air intake and recirculation motor: 182 %
Left front position mixing motor: 240 %
Right front position mixing motor: 94 %
Left front distribution motor position : 88 %
Right front distribution motor position: 3 %
Left rear mixing motor position: 14 %
Right rear mixing motor position: 48 %
Left rear distribution motor position : 4 %
Right rear distribution motor position: 86 %
Levende Data
Front condition evaporator sensor: --
Evaporator temperature sensor: 6550.0 °C
Passenger compartment air blower supply voltage: 11.40 V
Position of the air intake and recirculation motor: 182 %
Mixing motor position: 240 %
Distribution motor position: 88 %
Levende Data
Front condition evaporator sensor: --
Evaporator temperature sensor: 6550.0 °C
Passenger compartment air blower supply voltage: 11.40 V
Position of the air intake and recirculation motor: 182 %
Udgangs test
Controls
Mixer motor
Left front mixing motor
Right front mixing motor
Air distribution motor
Passenger compartment air blower
Distribution motor: ventilators