Car, MERCEDES, A 169, 169.032 A 170, 180 Sedan, 2005-, Automatic air conditioning (AAC)

Climate control - Automatic air conditioning (AAC) - 0

Identification

Production date: 06 10 11

Hardware number: 01.06

Software number: 10.06

Diagnostic version: 2.8

MB number for hardware: 16 95 45 19 08

Supplier: Not defined

Identifier: 02 08

VIN no: WDD2452071J177852

DTC

9001: Interrior air temperature sensor - circuit open or short

Controls

Clear DTC

Data stream

Power supply: 12 V

Engine speed: 0 rpm

Ambient temperature sensor: 55 °C

Interior air temperature sensor: 15 °C

Engine coolant temperature sensor: 33 °C

Evaporator temperature sensor: 26 °C

Rear blower electronic selector wheel: 3

Left sun sensor light intensity: 0 %

Right sun sensor light intensity: 0 %

Air quality sensor: 14.0 %

Multifunction sensor dewpoint temperature: 54 °C

Request to A/C compressor: 17 %

A/C compressor current consumption: 2048 mA

Defroster flap actuator motor position: 0 %

Target defroster flap actuator motor position: 0 %

Defroster flap actuator motor position: 0

Target defroster flap actuator motor position: 0

Stored defroster flap adjustment motor travel: 1299

Current defroster flap adjustment motor travel: 1299

Defroster flap normalizing of positioning motors: Performed

Defroster flap alignment of positioning motors: Not performed

Defroster flap mode: Normal

Defroster flap overvoltage/undervoltage: No

Defroster flap communication fault: No

Defroster flap excess temperature: No

Defroster flap electrical fault: No

Footwell flap motor position: 100 %

Target footwell flap positioning motor: 100 %

Footwell flap motor position: 1138

Target footwell flap positioning motor: 1138

Stored footwell flap adjustment motor travel: 1138

Current footwell flap adjustment motor travel: 1138

Footwell flap normalizing of positioning motors: Performed

Footwell flap alignment of positioning motors: Performed

Footwell flap mode: Normal

Footwell flap overvoltage/undervoltage: No

Footwell flap communication fault: No

Footwell flap excess temperature: No

Footwell flap electrical fault: No

Center outlet flap actuator motor position: 100 %

Target center outlet flap actuator motor position: 100 %

Center outlet flap actuator motor position: 1033

Target center outlet flap actuator motor position: 1033

Stored center outlet flap adjustment motor travel: 1033

Current center outlet flap adjustment motor travel: 1033

Center outlet flap normalizing of positioning motors: Performed

Center outlet flap alignment of positioning motors: Performed

Center outlet flap mode: Normal

Center outlet flap overvoltage/undervoltage: No

Center outlet flap communication fault: No

Center outlet flap excess temperature: No

Center outlet flap electrical fault: No

Recirculation air flap actuator motor position: 100 %

Target recirculation air flap actuator motor position: 100 %

Recirculation air flap actuator motor position: 1936

Target recirculation air flap actuator motor position: 1936

Stored recirculation air flap adjustment motor travel: 1936

Current recirculation air flap adjustment motor travel: 1936

Recirculation air flap normalizing of positioning motors: Performed

Recirculation air flap alignment of positioning motors: Performed

Recirculation air flap mode: Normal

Recirculation air flap overvoltage/undervoltage: No

Recirculation air flap communication fault: No

Recirculation air flap excess temperature: No

Recirculation air flap electrical fault: No

Left air mix flap motor position: 100 %

Target left air mix flap motor position: 100 %

Left air mix flap motor position: 1344

Target left air mix flap motor position: 1344

Stored left air mix flap adjustment motor travel: 1344

Current left air mix flap adjustment motor travel: 1344

Left air mix normalizing of positioning motors: Performed

Left air mix flap alignment of positioning motors: Performed

Left air mix flap mode: Normal

Left air mix flap overvoltage/undervoltage: No

Left air mix flap communication fault: No

Left air mix flap motor excess temperature: No

Left air mix flap motor electrical fault: No

Right air mix flap actuator motor position: 100 %

Target right air mix flap actuator motor position: 100 %

Right air mix flap actuator motor position: 1313

Target right air mix flap actuator motor position: 1313

Stored right air mix flap adjustment motor travel: 1313

Current right air mix flap adjustment motor travel: 1313

Right air mix normalizing of positioning motors: Performed

Right air mix flap alignment of positioning motors: Not performed

Right air mix flap mode: Normal

Right air mix flap overvoltage/undervoltage: No

Right air mix flap communication fault: No

Right air mix flap motor excess temperature: No

Right air mix flap motor electrical fault: No

Rear shutoff flap actuator motor position: 80 %

Target rear shutoff flap actuator motor position: 80 %

Rear shutoff flap actuator motor position: 1117

Target rear shutoff flap actuator motor position: 1117

Stored rear shutoff flap adjustment motor travel: 1397

Current rear shutoff flap adjustment motor travel: 1397

Rear shutoff flap normalizing of positioning motors: Performed

Rear shutoff flap alignment of positioning motors: Performed

Rear shutoff flap mode: Normal

Rear shutoff flap overvoltage/undervoltage: No

Rear shutoff flap communication fault: No

Rear shutoff flap excess temperature: No

Rear shutoff flap electrical fault: No

Temperature sensor: 25 °C

Blower motor current consumption: 0 A

Blower motor voltage: 0 V

Excessive temperature: No

Blower motor fault: No fault

Mode: Normal

Status: Stationary

In-car temperature sensor: -- °C

Actuators test

Controls

Defroster flap

Footwell flaps

Center outlet flap

Recirculated air flap

Left air mix flap motor

Right air mix flap motor

Rear shutoff flap

Blower motor

Electric suction fan

Illumination

Closing air recirculation flap (for cleaning)

Heating water circulation pump

Utility

Controls

Normalizing of positioning motors

Check of adjustment range of positioning motors

Teach in actuator motors

Breaking-in after replacement of refrigerant compressor

Configuration

Controls

Edit configuration