Bil, MERCEDES, A 169, 169.032 A 170, 180 Sedan, 2005-, Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

Production date: 06 10 11

Hardware number: 01.06

Software nummer: 10.06

Diagnose version: 2.8

MB number for hardware: 16 95 45 19 08

Supplier: Ikke defineret

Identificere : 02 08

Stel nr.: WDD2452071J177852

Fejlkoder

9001: Interrior air temperature sensor - circuit open or short

Controls

Clear DTC

Levende Data

Power supply: 12 V

Motor Hastighed: 0 Omdr.

Ambient temperature sensor: 55 °C

Interior air temperature sensor: 15 °C

Motor kølevæske temperatur føler: 33 °C

Evaporator temperature sensor: 26 °C

Rear blower electronic selector wheel: 3

Left sun sensor light intensity: 0 %

Right sun sensor light intensity: 0 %

Luftkvalitetsføler: 14.0 %

Multifunction sensor dewpoint temperature: 54 °C

Request to A/C compressor: 17 %

A/C compressor current consumption: 2048 mA

Defroster flap actuator motor position: 0 %

Target defroster flap actuator motor position: 0 %

Defroster flap actuator motor position: 0

Target defroster flap actuator motor position: 0

Stored defroster flap adjustment motor travel: 1299

Current defroster flap adjustment motor travel: 1299

Defroster flap normalizing of positioning motors: Udført

Defroster flap alignment of positioning motors: Not performed

Defroster flap mode: Normal

Defroster flap overvoltage/undervoltage: Nej

Defroster flap communication fault: Nej

Defroster flap excess temperature: Nej

Defroster flap electrical fault: Nej

Footwell flap motor position: 100 %

Target footwell flap positioning motor: 100 %

Footwell flap motor position: 1138

Target footwell flap positioning motor: 1138

Stored footwell flap adjustment motor travel: 1138

Current footwell flap adjustment motor travel: 1138

Footwell flap normalizing of positioning motors: Udført

Footwell flap alignment of positioning motors: Udført

Footwell flap mode: Normal

Footwell flap overvoltage/undervoltage: Nej

Footwell flap communication fault: Nej

Footwell flap excess temperature: Nej

Footwell flap electrical fault: Nej

Center outlet flap actuator motor position: 100 %

Target center outlet flap actuator motor position: 100 %

Center outlet flap actuator motor position: 1033

Target center outlet flap actuator motor position: 1033

Stored center outlet flap adjustment motor travel: 1033

Current center outlet flap adjustment motor travel: 1033

Center outlet flap normalizing of positioning motors: Udført

Center outlet flap alignment of positioning motors: Udført

Center outlet flap mode: Normal

Center outlet flap overvoltage/undervoltage: Nej

Center outlet flap communication fault: Nej

Center outlet flap excess temperature: Nej

Center outlet flap electrical fault: Nej

Recirculation air flap actuator motor position: 100 %

Target recirculation air flap actuator motor position: 100 %

Recirculation air flap actuator motor position: 1936

Target recirculation air flap actuator motor position: 1936

Stored recirculation air flap adjustment motor travel: 1936

Current recirculation air flap adjustment motor travel: 1936

Recirculation air flap normalizing of positioning motors: Udført

Recirculation air flap alignment of positioning motors: Udført

Recirculation air flap mode: Normal

Recirculation air flap overvoltage/undervoltage: Nej

Recirculation air flap communication fault: Nej

Recirculation air flap excess temperature: Nej

Recirculation air flap electrical fault: Nej

Left air mix flap motor position: 100 %

Target left air mix flap motor position: 100 %

Left air mix flap motor position: 1344

Target left air mix flap motor position: 1344

Stored left air mix flap adjustment motor travel: 1344

Current left air mix flap adjustment motor travel: 1344

Left air mix normalizing of positioning motors: Udført

Left air mix flap alignment of positioning motors: Udført

Left air mix flap mode: Normal

Left air mix flap overvoltage/undervoltage: Nej

Left air mix flap communication fault: Nej

Left air mix flap motor excess temperature: Nej

Left air mix flap motor electrical fault: Nej

Right air mix flap actuator motor position: 100 %

Target right air mix flap actuator motor position: 100 %

Right air mix flap actuator motor position: 1313

Target right air mix flap actuator motor position: 1313

Stored right air mix flap adjustment motor travel: 1313

Current right air mix flap adjustment motor travel: 1313

Right air mix normalizing of positioning motors: Udført

Right air mix flap alignment of positioning motors: Not performed

Right air mix flap mode: Normal

Right air mix flap overvoltage/undervoltage: Nej

Right air mix flap communication fault: Nej

Right air mix flap motor excess temperature: Nej

Right air mix flap motor electrical fault: Nej

Rear shutoff flap actuator motor position: 80 %

Target rear shutoff flap actuator motor position: 80 %

Rear shutoff flap actuator motor position: 1117

Target rear shutoff flap actuator motor position: 1117

Stored rear shutoff flap adjustment motor travel: 1397

Current rear shutoff flap adjustment motor travel: 1397

Rear shutoff flap normalizing of positioning motors: Udført

Rear shutoff flap alignment of positioning motors: Udført

Rear shutoff flap mode: Normal

Rear shutoff flap overvoltage/undervoltage: Nej

Rear shutoff flap communication fault: Nej

Rear shutoff flap excess temperature: Nej

Rear shutoff flap electrical fault: Nej

Temperature sensor: 25 °C

Blower motor current consumption: 0 A

Blæsermotor, spænding: 0 V

Excessive temperature: Nej

Blower motor fault: No fault

Mode: Normal

Status: Stationær

In-car temperature sensor: -- °C

Udgangs test

Controls

Defroster flap

Footwell flaps

Center outlet flap

Recirculated air flap

Left air mix flap motor

Right air mix flap motor

Rear shutoff flap

Blæsermotor

Electric suction fan

Illumination

Closing air recirculation flap (for cleaning)

Heating water circulation pump

Muligheder

Controls

Normalizing of positioning motors

Check of adjustment range of positioning motors

Teach in actuator motors

Breaking-in after replacement of refrigerant compressor

Konfiguration

Controls

Redigere konfiguration