LKW, VW, Amarok (2H, S1) 2010-, 2013 (D), Amarok, CNFA 2,0l TDI-CR , 90kW, 08 - Klima-, Heizung (08 KLH)
Klimaregelung - 08 - Klima-/ Heizung (08 KLH) - 0
Identifikation
ASAM/ODX file identification: EV_AirCondiFrontAU210
ASAM/ODX file version: 005001
Ersatzteilnummer: xxxxxxxxx
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FIN: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware-Teilenummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardware-Version: xxx
Programmierbarkeit: Programmierbar
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Erweiterte Identifikation
ASAM/ODX file identification: EV_AirCondiFrontAU210
ASAM/ODX file version: 005001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nein
Programmability status: flash memory faulty: Nein
Programmability status: communication error: Nein
Programmability status: flash memory not programmable: Nein
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gültig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gültig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gültig
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnosemodus: VW diagnostic
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware-Teilenummer: xxxxxxxxx
Hardware-Version: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Ersatzteilnummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmierbar
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Fehlercode lessen (Normaler Modus)
Controls
Fehlercode löschen
Fehlercode lessen (Aggressiver Modus)
Controls
Fehlercode löschen
Ist-Werte
Klemme 30: 4.8 V
Terminal 15: AUS
Klemme 75: AUS
Steuergerät Temperatur: 48 °C
Terminal 58d dimmer: 24.0 %
Terminal 58s dimmer: 24.0 %
Drive cycles: 12336
Temperature unit: °C
Stop process prevented: basic setting active: Stop release for start-stop function
Stop process prevented: airflow control deviation: Stop release for start-stop function
Stop process prevented: defrost active: Stop release for start-stop function
Stop process prevented: outside air temperature: Stop release for start-stop function
Stop process prevented: interior control deviation: Stop release for start-stop function
Stop process prevented: window condensation likely: Override of stop for air-conditioning settings
Stop process prevented: temperature setting maximum or minimum: Override of stop for air-conditioning settings
Stop process prevented: stop release for A/C comfort adaptation: Stop release for start-stop function
Stop process prevented: output diagnostic test mode (DTM): Stop release for start-stop function
Start process requested: stop release for A/C comfort adaptation: Kein Neustart
Start process requested: maximum stop duration reached: Kein Neustart
Start process requested: defrost active: Kein Neustart
Start process requested: temperature setting maximum or minimum: Kein Neustart
Start process requested: airflow control deviation: Kein Neustart
Start process requested: outside air temperature: Kein Neustart
Start process requested: interior control deviation: Neustart
Start process requested: dew point gradient: Neustart
Start process requested: window condensation likely: Kein Neustart
Start process requested: humidity inside: Kein Neustart
Number of prevented stop processes: window condensation likely: 12336
Number of prevented stop processes: temperature setting maximum or minimum: 12336
Number of prevented stop processes: stop release for A/C comfort adaptation: 12336
Number of prevented stop processes: output diagnostic test mode (DTM): 12336
Number of prevented stop processes: basic setting active: 12336
Number of prevented stop processes: airflow control deviation: 12336
Number of prevented stop processes: defrost active: 12336
Number of prevented stop processes: outside air temperature: 12336
Number of prevented stop processes interior control deviation: 12336
Number of requested start processes: interior control deviation: 12336
Number of requested start processes: dew point gradient: 12336
Number of requested start processes: window condensation likely: 12336
Number of requested start processes: stop release for A/C comfort adaptation: 12336
Number of requested start processes: maximum stop duration reached: 12336
Number of requested start processes: defrost active: 12336
Number of requested start processes: temperature setting maximum or minimum: 12336
Number of requested start processes: airflow control deviation: 12336
Number of requested start processes: outside air temperature: 12336
Start-stop conditions: Stop release
Start-stop enabling: System malfunction
Analysis 1: channel: 111
Analysis 1: value: --
Target value of temperature flap: 1542.0 %
Stellmotor für Temperaturklappe: 1542.0 %
Target value of central air flap motor: 1542.0 %
Central air flap motor: 1542.0 %
Target value of defroster flap: 1542.0 %
Defroster flap: 1542.0 %
Specified value for fresh air/recirc air flow flap: 1542.0 %
Fresh air/recirculation air flow flap: 1542.0 %
Radiator fan 1 activation: 24.0 %
Radiator fan 2 activation: 24.0 %
Compressor shut-off requirement:
Compressor current: 240 mA
Compressor current, target value: 240 mA
Kältemitteldruck: 9.6 Bar
Coolant fan activation target value: 19.2 %
Idle speed increase: AUS
Außentemperatur: -26.0 °C
Temperatursensor Fußraum rechts: 1228.6 °C
Temperature after evaporator: -16.0 °C
Innenraum-Temperatursensor: 1193.6 °C
Target blower voltage: 4.8 V
Status of recirculation air: Fresh air
Temperatursensor-Gebläse: 768 1/min
Blower voltage: 4.8 V
Supply voltage terminal 30 for actuators: 4.8 V
Supply voltage for external components: 4.8 V
Time since ignition off: hours: 48 Stunden
Time since ignition off: minutes: 48 min
A/C compressor torque: -1.0 N·m
Operating hours of A/C: 12336 Stunden
Operating hours of A/C compressor: 12336 Stunden
Sonnensensor, Lichtintensität: 1233.6 W/m²
Validity of compressor torque: Gültig
Frontscheibenwischer: Nicht aktiv
Enabling for auxiliary heater operation: AUS
High pressure events in current driving cycle: 16
Counter of compressor activations: 12336
Erase DTC memory counter: 12336
Counter of window condensation events: 12336
Compressor power reduction by engine control module: Not reduced
Counter of compressor switch-offs: 48
Compressor power restriction: Keine Beschränkung
Switch-on conditions for auxiliary heater: engine running: Nein
Switch-on conditions for auxiliary heater: A/C control active: Nein
Switch-on conditions for auxiliary heater: exterior temperature < 10°C: Nein
Switch-on conditions for auxiliary heater: temperature flap < 80%: Nein
Switch-on conditions for auxiliary heater: diesel: Ja
Switch-on conditions for auxiliary heater: blower voltage > 2.5 V: Ja
Switch-on conditions for auxiliary heater: auxiliary heater allowed via MMI: Nein
Compressor shut-off condition, last:
Compressor shut-off requirement, penultimate:
Compressor shut-off requirement, antepenultimate:
Moisture and temperature sensor, dew point: 1194.1 °C
Moisture and temperature sensor, relative humidity: 24.0 %
Moisture and temperature sensor, temperature: -16.0 °C
Frontscheibentemperatur: 1194.1 °C
Rückfahrleuchten: AUS
Pressing a button: defrost: AUS
Pressing a button: recirculating air: AUS
Pressing a button: OFF: AUS
Pressing a button: AUTO: EIN
Pressing a button: AC: AUS
Left push-and-rotary knob counter: 48
Right push-and-rotary knob counter: 48
Energy management deactivation stage: 0
Energy management fan control status: Nicht aktiv
A/C refrigerant pressure sensor: In Ordnung
Doors and windows: right rear side window: 48
Doors and windows: sunroof: 48
Doors and windows: driver door: 48
Doors and windows: front passenger door: 48
Doors and windows: left rear door: 48
Doors and windows: right rear door: 48
Doors and windows: driver door side window: 48
Doors and windows: front passenger door side window: 48
Doors and windows: left rear side window: 48
Left front outlet temperature sensor: 1228.6 °C
Left front control code: 8 °C
Left center vent motor: 12336
Target value of left center vent flap motor: 12336
Left center vent motor stop open: 12336
Left center vent motor stop closed: 12336
Left footwell temperature flap motor: 12336
Target value of left footwell temperature flap motor: 12336
Left footwell temperature flap motor stop open: 12336
Left footwell temperature flap motor stop closed: 12336
Defrost flap motor for right side window: 12336
Defrost flap motor for right side window, target value: 12336
Defrost flap motor for right side window stop open: 12336
Defrost flap motor for right side window stop closed: 12336
Right rear specified blowing temperature: -16.0 °C
Back pressure flap motor: 12336
Target value of back pressure flap motor: 12336
Back pressure flap motor stop open: 12336
Back pressure flap motor stop closed: 12336
Driving time remaining for basic setting of compressor run in: 48 sec
Release for consumption recommendation: Nein
Center push-and-rotary knob counter: 48
Kühlmitteltemperatur: -40.50 °C
Motordrehzahl: 0.00 1/min
Fahrgeschwindigkeit: -- km/h
Stellgliedtest
Controls
Segment test
Left temperature flap motor
Defroster flap motor
Activation A/C compressor
Frischluftgebläse vorne
Back pressure door motor
Central air flap motor
Coolant recirculation pump
Kühlmittellüfter
MMI display request
Maximale Heizleistung
Maximale Kühlleistung
Coolant shut-off valve
Grundeinstellung
Controls
Endanschläge der Klappen anpassen
Compressor run-in and A/C power test
End compressor run-in
Gebläse und Klappen aktivieren
Resetting of all adaptations
Erase counter for start and stop processes
Dienstprogramme
Controls
Analysis 6
Activating and deactivating all development messages
Analysis 9
Analysis 10
Analysis 11
Store recirculation air setting for terminal 15 off
Ignore compressor switch-off by engine control module
Gear ratio of engine - A/C compressor
Temperature clamping after evaporator
Air recirculation when driving in reverse
Fresh air blower voltage offset
Temperatur Offset, Sommerbetrieb
Temperatur Offset, Winterbetrieb
Temperaturschwellwert für Aktivierung der Zusatzheizung
Air recirculation with wipe/wash
Verminderte Kondenswasserbildung auf Scheiben bei hoher Luftfeuchtigkeit
Leakage air to footwell
Runtime for compressor run-in basic setting
Tolerance range for basic setting of flap end stops
Tolerance range for flap end stops
Blower lowering for slow travel
Blower voltage during compressor run-in
Reset all counters
Stop release for start-stop function
A/C Komfortparameter für Start-Stop Funktion
Window condensation parameter for start-stop function
Production mode
Deactivate production mode
Deaktivierung der Start-Stop Funktion
Analysis 12
Blower motor type
Konfiguration
Controls
Konfiguration
Handbetrieb
Controls
SFD
Konfiguration