Commercial, VW, Transporter (SH, SJ) 2019-, 2022 (N), Transporter, Petrol VDOHC, 7A - Door automatic rear passenger side (7A DAP)
Dør moduler - 7A - Door automatic rear passenger side (7A DAP) - 0
Identifikation
ASAM/ODX file identifikation: EV_SlideDoorPasseHufT6PA
ASAM/ODX file version: 001001
Dele nummer: xxxxxxxxx
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
Stel nr.: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware vare nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardwareversion: xxx
Programmerbarhed: Programmerbare
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Advanceret identifikation
ASAM/ODX file identifikation: EV_SlideDoorPasseHufT6PA
ASAM/ODX file version: 001001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nej
Programmability status: flash memory faulty: Nej
Programmability status: communication error: Nej
Programmability status: flash memory not programmable: Nej
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gyldig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gyldig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gyldig
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnostisk tilstand: VW diagnose
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware vare nummer: xxxxxxxxx
Hardwareversion: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Dele nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmerbare
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Read DTC (Normal mode)
Controls
Clear DTC
Read DTC (Agressive mode)
Controls
Clear DTC
Levende Data
Security access: number of invalid keys, counter: 0
Basic settings status 2: Ikke aktiv
Communication status of data bus 1: CAN communication status:
Data logger triggering:
Standard - ambient data 1: hours: 3
Standard - ambient data 1: day: 24
Standard - ambient data 1: minutes: 0
Standard - ambient data 1: seconds: 48
Standard - ambient data 1: unlearning counter: 48
Standard - ambient data 1: odometer reading: 3158064 km
Standard - ambient data 1: year: 2012
Standard - ambient data 1: month: 0
Number of unscheduled ECU resets: status: 12336
Read ambient data: signal from door lock - catch: --
Read ambient data: pinch protection sensor: --
Read ambient data: installed on right side: --
Read ambient data: installed on left side: --
Read ambient data: front button for automatic sliding door: --
Read ambient data: actual value: --
Read ambient data: maximum value: --
Read ambient data: sliding door position: --
Read ambient data: longitudinal slope: -- °
Read ambient data: transverse slope: -- °
Read ambient data: terminal 30: 7.7 V
Read ambient data: activation, motor for automatic sliding door: --
Read ambient data: indicator lamp 3 for sliding door: --
Read ambient data: sliding door indicator lamp: --
Read ambient data: play protection, motor for automatic sliding door: --
Read ambient data: automatic sliding door acoustic: --
Read ambient data: motor current: -- A
Parameter monitor 1: parameter address: 3158064
Parameter monitor 1: parameter value: 12336
Status of input signals 1: pinch protection sensor: Ikke aktiveret
Status of input signals 1: installed on right side: Ja
Status of input signals 1: installed on left side: Ja
Status of input signals 1: front button for automatic sliding door: Ikke aktiveret
Status of input signals 1: deactivation switch: Ikke aktiveret
CAN input signal(s) status: request through vehicle key with remote control: Ikke aktiveret
CAN input signal(s) status: signal from door lock - catch: Ikke aktiveret
CAN input signal(s) status: signal from door lock - detent: Ikke aktiveret
CAN input signal(s) status: child safety: betjenes
CAN input signal(s) status: switch for outside door handle: betjenes
CAN input signal(s) status: switch for inside door handle: Ikke aktiveret
CAN input signal(s) status: static current measuring mode: Ikke aktiv
CAN input signal(s) status: transport mode: Ikke aktiv
CAN input signal(s) status: signal vehicle speed (alt bit): Ikke aktiv
CAN input signal(s) status: signal from door lock - engaged: Ikke aktiv
CAN input signal(s) status: door lock - safe: Ikke aktiv
CAN input signal(s) status: restart: Ikke aktiv
CAN input signal(s) status: start-stop: Ikke aktiv
CAN input signal(s) status: start-stop enabling: System malfunction
CAN input signal(s) status: terminal status: Tænd
CAN input signal(s) status: terminal S: Tænd
CAN input signal(s) status: terminal 50: Sluk
CAN input signal(s) status: terminal 15: Sluk
CAN input signal(s) status: eCall operating state: Ikke aktiv
CAN input signal(s) status: status unlock request door rear left: Ikke aktiv
CAN input signal(s) status: status unlock request door rear right: Ikke aktiv
CAN input signal(s) status: kessy: Aktiv
CAN input signal(s) status: network diagnostics enable, central activation: Network diagnostics enable, not supported
CAN input signal(s) status: network diagnosis: Ikke aktiv
CAN input signal(s) status: installed on right side: Nej
CAN input signal(s) status: installed on left side: Nej
Status of output signals: activation, motor for automatic sliding door:
Status of output signals: indicator lamp 3 for sliding door: Ikke aktiv
Status of output signals: sliding door indicator lamp: Ikke aktiv
Status of output signals: automatic sliding door acoustic: Aktiv
CAN output signal(s) status: customer service: Ingen fejl
CAN output signal(s) status: indicator lamp for safety belt warning: Ikke aktiveret
CAN output signal(s) status: force limitation: Ikke aktiveret
CAN output signal(s) status: co-clamping protection seal defect io: Fejl
CAN output signal(s) status: pinch protection sensor: betjenes
CAN output signal(s) status: automatic sliding door moving, opening: Ikke aktiv
CAN output signal(s) status: automatic sliding door moving, closing: Ikke aktiv
Basic setting of opening width: standardization value: 6168
Basic setting of opening width: condition: Ikke kalibreret
Basic setting of opening width: number of requested tests: 12336
Number of driving cycles for automatic sliding door: 3158064
Position of automatic sliding door: 12336.0
Position of automatic sliding door, maximum value: 12336.0
Play protection, motor for automatic sliding door: counter: 48
Play protection, motor for automatic sliding door: activation limitation: 48
Play protection, motor for automatic sliding door: play protection: Ikke aktiv
Play protection, motor for automatic sliding door: deactivation limitation: 24
Activation of start-stop function: Ikke aktiv
Installed on right side: Ikke aktiv
Installed on left side: Ikke aktiv
Static current measuring mode: Aktiv
Transport mode: Aktiv
Customer service mode: Ikke aktiv
End of assembly line mode (EOL): Ikke aktiv
Basic setting, position: --
Basic setting, maximum value during opening: --
Basic setting, current value during opening: --
Basic setting, maximum value during closing: --
Basic setting, current value during closing: --
Longitudinal slope: status: 48 °
Transverse slope: status: 48 °
History data 1: third revers position: 12336
History data 1: fourth revers reason: 48
History data 1: fourth revers position: 12336
History data 1: last revers reason: 48
History data 1: last revers position: 12336
History data 1: second revers reason: 48
History data 1: second revers position: 12336
History data 1: third revers reason: 48
History data 2: history data 1: 48
History data 2: second operator unit: 48
History data 2: third operator unit: 48
History data 2: fourth operator unit: 48
History data 3: third stop position: 12336
History data 3: fourth stop reason: 48
History data 3: fourth stop position: 12336
History data 3: last stop reason: 48
History data 3: last stop position: 12336
History data 3: second stop reason: 48
History data 3: second stop position: 12336
History data 3: third stop reason: 48
Reject reason open: status: 48 °
Reject reason close: status: 48 °
Trace latch opening: status: --
Trace latch closing: status: --
Consistency of EEPROM data: dataset download possible: --
Consistency of EEPROM data: data record modification: --
Consistency of EEPROM data: data consistency: --
Consistency of EEPROM data: error during last data record download: --
Terminal 30 : V
Activation current: motor for automatic sliding door activation: A
Køretøjs hastighed :
Basic setting
Controls
Sliding door indicator lamp
Automatic sliding door acoustic
Closing automatic sliding door
Opening automatic sliding door
Activation, motor for automatic sliding door
Resetting of all adaptation values
Sliding door indicator lamp 2
Resetting of all adaptations
Muligheder
Controls
Activating and deactivating all development messages
Writing parameter
Customer service mode
Read parameter address
Deactivate factory mode
Sound
Konfiguration
Controls
Konfiguration
Manual mode
Controls
SFD
Konfiguration