Commercial, VW, Transporter (SH, SJ) 2019-, 2022 (N), Transporter, Petrol VDOHC, 7A - Door automatic rear passenger side (7A DAP)

Dør moduler - 7A - Door automatic rear passenger side (7A DAP) - 0

Identifikation

ASAM/ODX file identifikation: EV_SlideDoorPasseHufT6PA

ASAM/ODX file version: 001001

Dele nummer: xxxxxxxxx

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

Stel nr.: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware vare nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardwareversion: xxx

Programmerbarhed: Programmerbare

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Advanceret identifikation

ASAM/ODX file identifikation: EV_SlideDoorPasseHufT6PA

ASAM/ODX file version: 001001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nej

Programmability status: flash memory faulty: Nej

Programmability status: communication error: Nej

Programmability status: flash memory not programmable: Nej

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gyldig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gyldig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gyldig

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostisk tilstand: VW diagnose

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware vare nummer: xxxxxxxxx

Hardwareversion: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Dele nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmerbare

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Levende Data

Security access: number of invalid keys, counter: 0

Basic settings status 2: Ikke aktiv

Communication status of data bus 1: CAN communication status:

Data logger triggering:

Standard - ambient data 1: hours: 3

Standard - ambient data 1: day: 24

Standard - ambient data 1: minutes: 0

Standard - ambient data 1: seconds: 48

Standard - ambient data 1: unlearning counter: 48

Standard - ambient data 1: odometer reading: 3158064 km

Standard - ambient data 1: year: 2012

Standard - ambient data 1: month: 0

Number of unscheduled ECU resets: status: 12336

Read ambient data: signal from door lock - catch: --

Read ambient data: pinch protection sensor: --

Read ambient data: installed on right side: --

Read ambient data: installed on left side: --

Read ambient data: front button for automatic sliding door: --

Read ambient data: actual value: --

Read ambient data: maximum value: --

Read ambient data: sliding door position: --

Read ambient data: longitudinal slope: -- °

Read ambient data: transverse slope: -- °

Read ambient data: terminal 30: 7.7 V

Read ambient data: activation, motor for automatic sliding door: --

Read ambient data: indicator lamp 3 for sliding door: --

Read ambient data: sliding door indicator lamp: --

Read ambient data: play protection, motor for automatic sliding door: --

Read ambient data: automatic sliding door acoustic: --

Read ambient data: motor current: -- A

Parameter monitor 1: parameter address: 3158064

Parameter monitor 1: parameter value: 12336

Status of input signals 1: pinch protection sensor: Ikke aktiveret

Status of input signals 1: installed on right side: Ja

Status of input signals 1: installed on left side: Ja

Status of input signals 1: front button for automatic sliding door: Ikke aktiveret

Status of input signals 1: deactivation switch: Ikke aktiveret

CAN input signal(s) status: request through vehicle key with remote control: Ikke aktiveret

CAN input signal(s) status: signal from door lock - catch: Ikke aktiveret

CAN input signal(s) status: signal from door lock - detent: Ikke aktiveret

CAN input signal(s) status: child safety: betjenes

CAN input signal(s) status: switch for outside door handle: betjenes

CAN input signal(s) status: switch for inside door handle: Ikke aktiveret

CAN input signal(s) status: static current measuring mode: Ikke aktiv

CAN input signal(s) status: transport mode: Ikke aktiv

CAN input signal(s) status: signal vehicle speed (alt bit): Ikke aktiv

CAN input signal(s) status: signal from door lock - engaged: Ikke aktiv

CAN input signal(s) status: door lock - safe: Ikke aktiv

CAN input signal(s) status: restart: Ikke aktiv

CAN input signal(s) status: start-stop: Ikke aktiv

CAN input signal(s) status: start-stop enabling: System malfunction

CAN input signal(s) status: terminal status: Tænd

CAN input signal(s) status: terminal S: Tænd

CAN input signal(s) status: terminal 50: Sluk

CAN input signal(s) status: terminal 15: Sluk

CAN input signal(s) status: eCall operating state: Ikke aktiv

CAN input signal(s) status: status unlock request door rear left: Ikke aktiv

CAN input signal(s) status: status unlock request door rear right: Ikke aktiv

CAN input signal(s) status: kessy: Aktiv

CAN input signal(s) status: network diagnostics enable, central activation: Network diagnostics enable, not supported

CAN input signal(s) status: network diagnosis: Ikke aktiv

CAN input signal(s) status: installed on right side: Nej

CAN input signal(s) status: installed on left side: Nej

Status of output signals: activation, motor for automatic sliding door:

Status of output signals: indicator lamp 3 for sliding door: Ikke aktiv

Status of output signals: sliding door indicator lamp: Ikke aktiv

Status of output signals: automatic sliding door acoustic: Aktiv

CAN output signal(s) status: customer service: Ingen fejl

CAN output signal(s) status: indicator lamp for safety belt warning: Ikke aktiveret

CAN output signal(s) status: force limitation: Ikke aktiveret

CAN output signal(s) status: co-clamping protection seal defect io: Fejl

CAN output signal(s) status: pinch protection sensor: betjenes

CAN output signal(s) status: automatic sliding door moving, opening: Ikke aktiv

CAN output signal(s) status: automatic sliding door moving, closing: Ikke aktiv

Basic setting of opening width: standardization value: 6168

Basic setting of opening width: condition: Ikke kalibreret

Basic setting of opening width: number of requested tests: 12336

Number of driving cycles for automatic sliding door: 3158064

Position of automatic sliding door: 12336.0

Position of automatic sliding door, maximum value: 12336.0

Play protection, motor for automatic sliding door: counter: 48

Play protection, motor for automatic sliding door: activation limitation: 48

Play protection, motor for automatic sliding door: play protection: Ikke aktiv

Play protection, motor for automatic sliding door: deactivation limitation: 24

Activation of start-stop function: Ikke aktiv

Installed on right side: Ikke aktiv

Installed on left side: Ikke aktiv

Static current measuring mode: Aktiv

Transport mode: Aktiv

Customer service mode: Ikke aktiv

End of assembly line mode (EOL): Ikke aktiv

Basic setting, position: --

Basic setting, maximum value during opening: --

Basic setting, current value during opening: --

Basic setting, maximum value during closing: --

Basic setting, current value during closing: --

Longitudinal slope: status: 48 °

Transverse slope: status: 48 °

History data 1: third revers position: 12336

History data 1: fourth revers reason: 48

History data 1: fourth revers position: 12336

History data 1: last revers reason: 48

History data 1: last revers position: 12336

History data 1: second revers reason: 48

History data 1: second revers position: 12336

History data 1: third revers reason: 48

History data 2: history data 1: 48

History data 2: second operator unit: 48

History data 2: third operator unit: 48

History data 2: fourth operator unit: 48

History data 3: third stop position: 12336

History data 3: fourth stop reason: 48

History data 3: fourth stop position: 12336

History data 3: last stop reason: 48

History data 3: last stop position: 12336

History data 3: second stop reason: 48

History data 3: second stop position: 12336

History data 3: third stop reason: 48

Reject reason open: status: 48 °

Reject reason close: status: 48 °

Trace latch opening: status: --

Trace latch closing: status: --

Consistency of EEPROM data: dataset download possible: --

Consistency of EEPROM data: data record modification: --

Consistency of EEPROM data: data consistency: --

Consistency of EEPROM data: error during last data record download: --

Terminal 30 : V

Activation current: motor for automatic sliding door activation: A

Køretøjs hastighed :

Basic setting

Controls

Sliding door indicator lamp

Automatic sliding door acoustic

Closing automatic sliding door

Opening automatic sliding door

Activation, motor for automatic sliding door

Resetting of all adaptation values

Sliding door indicator lamp 2

Resetting of all adaptations

Muligheder

Controls

Activating and deactivating all development messages

Writing parameter

Customer service mode

Read parameter address

Deactivate factory mode

Sound

Konfiguration

Controls

Konfiguration

Manual mode

Controls

SFD

Konfiguration