LKW, VW, Crafter (2E, 2F) 2006-, 2015 (F) , Crafter, CSLB 2.0l TDI CR, 84kW, 98 - Tire pressure monitoring 21V LT3 (TPM21V)
Reifendrucküberwachung - 98 - Tire pressure monitoring 21V LT3 (TPM21V) - 0
Identifikation
MB Hardwarenummer: 9064467821
Diagnoseversion: 3.1
Hardwarenummer: 07.30
Softwarenummer: 07.34
Lieferant: Borg
Diagnoseversion: 03 01
FIN (ursprünglich): --
FIN:
Fehlercode
C141: No CAN message from signal acquisition and actuation module control unit
Controls
Fehlercode löschen
Ist-Werte
Voltage supply at control module: 1108 V
Front or rear sensor localization: Erfolgreich
Left or right sensor localization: Erfolgreich
Geber für Außentemperatur: 33 °C
Reading of main odometer: 538500 km
Zündungstatus: AUS
RDK tire pressure control: Nicht verfügbar
Ländercode: -
Rear RDK decoder antenna: In Ordnung
Left front wheel electronics identification number: 10102B2
Right front wheel electronics identification number: 30102D4
Right rear wheel electronics identification number: 50102F6
Left rear wheel electronics identification number: 70102B8
Front axle tire pressure: 1 Bar
Rear axle tire pressure: 6 Bar
NHTSA coding: Aktiv
Speicher Nachricht
Message 1: wheel electronics identification number: A1 00 00 B2
Message 1: position: Hinten links
Message 1: tire pressure (Specified pressure): 4 Bar
Message 1: tire temperature: 147 °C
Message 1: tire pressure: 3 Bar
Message 1: kilometer reading: 533040 km
Message 1: readout in multifunction display: Correct tire pressure
Message 1: ambient temperature: 86 °C
Message 2: wheel electronics identification number: B3 00 00 C4
Message 2: position: Vorne links
Message 2: tire pressure (Specified pressure): 0 Bar
Message 2: tire temperature: -50 °C
Message 2: tire pressure: 0 Bar
Message 2: kilometer reading: 0 km
Message 2: readout in multifunction display: No warning
Message 2: ambient temperature: -40 °C
Message 3: wheel electronics identification number: C5 00 00 D6
Message 3: position: Vorne links
Message 3: tire pressure (Specified pressure): 0 Bar
Message 3: tire temperature: -50 °C
Message 3: tire pressure: 0 Bar
Message 3: kilometer reading: 0 km
Message 3: readout in multifunction display: No warning
Message 3: ambient temperature: -40 °C
Message 4: wheel electronics identification number: D7 00 00 E8
Message 4: position: Vorne links
Message 4: tire pressure (Specified pressure): 0 Bar
Message 4: tire temperature: -50 °C
Message 4: tire pressure: 0 Bar
Message 4: kilometer reading: 0 km
Message 4: readout in multifunction display: No warning
Message 4: ambient temperature: -40 °C
Message 5: wheel electronics identification number: E9 00 00 F0
Message 5: position: Vorne links
Message 5: tire pressure (Specified pressure): 0 Bar
Message 5: tire temperature: -50 °C
Message 5: tire pressure: 0 Bar
Message 5: kilometer reading: 0 km
Message 5: readout in multifunction display: No warning
Message 5: ambient temperature: -40 °C
Speicher Aktivierung
Activation no. 1: tire pressure (Wheel electronics no. 1): 3 Bar
Activation no. 1: tire pressure (Wheel electronics no. 2): 3 Bar
Activation no. 1: tire pressure (Wheel electronics no. 4): 1 Bar
Activation no. 1: tire pressure (Wheel electronics no. 3): 2 Bar
Activation no. 1: tire temperature (Wheel electronics no. 1): 63 °C
Activation no. 1: tire temperature (Wheel electronics no. 2): -8 °C
Activation no. 1: tire temperature (Wheel electronics no. 4): 147 °C
Activation no. 1: tire temperature (Wheel electronics no. 3): 98 °C
Activation no. 1: ambient temperature: 32 °C
Activation no. 1: kilometer reading: 538432 km
Activation no. 1: activation sequence: Automatic activation
Activation no. 1: result: Activation was completed successfully
Activation no. 2: tire pressure (Wheel electronics no. 1): 3 Bar
Activation no. 2: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 2: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 2: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 2: tire temperature (Wheel electronics no. 1): 34 °C
Activation no. 2: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 2: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 2: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 2: ambient temperature: 26 °C
Activation no. 2: kilometer reading: 33648 km
Activation no. 2: activation sequence: Automatic activation
Activation no. 2: result: Activation was completed successfully
Activation no. 3: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 3: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 3: ambient temperature: -40 °C
Activation no. 3: kilometer reading: 0 km
Activation no. 3: activation sequence: Automatic activation
Activation no. 3: result: Activation was unsuccessful
Activation no. 4: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 4: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 4: ambient temperature: -40 °C
Activation no. 4: kilometer reading: 0 km
Activation no. 4: activation sequence: Automatic activation
Activation no. 4: result: Activation was unsuccessful
Activation no. 5: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 5: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 5: ambient temperature: -40 °C
Activation no. 5: kilometer reading: 0 km
Activation no. 5: activation sequence: Automatic activation
Activation no. 5: result: Activation was unsuccessful
Stellgliedtest
Controls
Left front signal transfer test
Right front signal transfer test
Left rear signal transfer test
Right rear signal transfer test
Dienstprogramme
Controls
Wheel electronics identification number