Bil, GEELY, Emgrand EC7, EC715, Continuously variable transmission (CVT)
transakse - Continuously variable transmission (CVT) - 0
Identifikation
Flashing device ID: CONTI_0484
Flash date: --
Software version number: T
Software ID OEM number: 0
Software packing: CGI209C01A
OEM ID number: 06601256ABCDEFGHI
Hardware number: 482810
Hardware version nummer: 0000532941880501
Boot software number: 48281033333333330000
Fejlkoder
P0301: Cylinder 1 fejltænding påvist
P0033: Turbocharger bypass solenoid valve - circuit malfunction
Controls
Clear DTC
Levende Data
Engine speed (CAN bus): 1156.5 Omdr.
Køretøjets hastighed sensor: 85 km/h
Throttle position sensor (CAN): 40.0 %
Primary speed sensor: 21.2 Omdr.
Output shaft speed: 21.2 Omdr.
Clutch slip: 644.5 Omdr.
PWM duty cycle for EDS1: 33.3 %
PWM duty cycle for EDS2: 33.3 %
PWM duty cycle for EDS3: 33.3 %
Oil temperature: 45.0 °C
Gear transmission ratio: 4.626
Lever position: 12
Nummer af fejlkoder: 68
Check motor fejllampe: Sluk
Motordrejningsmoment: 20.0 N·m
Brake status: Ja
Brake fault: Nej
Shift lock: Nej
Motor kølevæske temperatur føler: 37.0 °C
ESP status: Ikke aktiv
ABS active: Ikke aktiv
Dynamic braking with ABS: Nej
ASR status: Aktiv
EDS status: Ikke aktiv
Pressure regulator commanded current of pulley 1: 462.6 mA
Pressure regulator commanded current of pulley 2: 462.6 mA
Pressure regulator commanded current of clutch: 462.6 mA
Target ratio: 0.5
Ratio gradient: -19.5 1/s
Beregnet motordrejningsmoment: 4476.0 N·m
Secondary pulley speed: 1156.5 Omdr.
Pressure regulator actual current of pulley 1: 462.6 mA
Pressure regulator actual current of pulley 2: 462.6 mA
Pressure regulator actual current of clutch: 462.6 mA
Target clutch pressure: 46.3 bar
Commanded current pressure regulator Pulley1: 46.3 bar
Commanded pulley 2 pressure: 46.3 bar
ZF reset counter: 4626
SV reset counter: 4626
TRAP reset counter: 4626
TSK reset counter: 4626
Vehicle speed output: 46.3 km/h
Average vehicle speed: 46.3 km/h
High side voltage: 8.50 V
Tændingsspænding: 8.50 V
Supply voltage for sensors of group 1: 8.50 V
Supply voltage 2 for sensors: 8.50 V
Kilometer tæller: 303174162 km
Batteri spænding: 8.50 V
External WID reset counter: 4626
Internal WID reset counter: 4626
Gearvælgerstilling: Position P
Koblingsstatus:
Target clutch pressure: 8.5 bar
Muligheder
Controls
Reset TCM learned