PKW, VW, Golf (AU, BE, BX) USA 2013-, 2020 (L), Saloon , Petrol LSOHC, 80 - Batterieregelung Zusatzspeicher 1 (80 BR1)
Stromversorgungs- steuerung - 80 - Batterieregelung Zusatzspeicher 1 (80 BR1) - 0
Identifikation
ASAM/ODX file identification: EV_BMS12VLiIonSDIAU49X
ASAM/ODX file version: 001001
Ersatzteilnummer: xxxxxxxxx
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FIN: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware-Teilenummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardware-Version: xxx
Programmierbarkeit: Programmierbar
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Erweiterte Identifikation
ASAM/ODX file identification: EV_BMS12VLiIonSDIAU49X
ASAM/ODX file version: 001001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nein
Programmability status: flash memory faulty: Nein
Programmability status: communication error: Nein
Programmability status: flash memory not programmable: Nein
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gültig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gültig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gültig
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnosemodus: VW diagnostic
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware-Teilenummer: xxxxxxxxx
Hardware-Version: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Ersatzteilnummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmierbar
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Fehlercode lessen (Normaler Modus)
Controls
Fehlercode löschen
Fehlercode lessen (Aggressiver Modus)
Controls
Fehlercode löschen
Ist-Werte
Actuator test: status: Nicht aktiv
Security access: number of invalid keys, counter: 0
Terminal 15 status via CAN:
Initialization status: Aktiv
Power reduction status: Nicht aktiv
Protection of posit. terminal of high-voltage / hybrid battery: Offen
Crash signal: Nicht aktiv
Workshop code and date of last reset of crash shutdown: workshop code: 30 30 30 30 30 30
Workshop code and date of last reset of crash shutdown: date: 3158064.0
Operating mode, nominal value:
Betriebsart:
History data 1: HV BHDM 01 1: 48.0
History data 1: HV BHDM 01 2: 48.0
History data 1: HV BHDM 01 3: 48.0
History data 2: HV BHDM 02 1: 48.0
History data 2: HV BHDM 02 2: 48.0
History data 2: HV BHDM 02 3: 48.0
History data 3: HV BHDM 03 1: 48.0
History data 3: HV BHDM 03 2: 48.0
History data 3: HV BHDM 03 3: 48.0
History data 5: HV BHDM 05 1: 48
History data 6: HV BHDM 06 1: 48.0
History data 6: HV BHDM 06 2: 48.0
History data 6: HV BHDM 06 3: 48.0
History data 9: HV BHDM 09 1: 48.0
History data 10: HV BHDM 10 1: 48.0
History data 11: HV BHDM 11 1: 48.0
History data 11: HV BHDM 11 2: 48.0
History data 11: HV BHDM 11 3: 48.0
History data 12: HV BHDM 12 1: 48.0
History data 12: HV BHDM 12 2: 48.0
History data 12: HV BHDM 12 3: 48.0
History data 13: HV BHDM 13 1: 48.0
History data 14: HV BHDM 14 1: 12336.0
History data 14: HV BHDM 14 2: 12336.0
History data 15: HV BHDM 15 1: 48.0
History data 15: HV BHDM 15 2: 48.0
History data 15: HV BHDM 15 3: 12336.0
History data 16: HV BHDM 16 1: 48.0
History data 16: HV BHDM 16 2: 12336.0
History data 16: HV BHDM 16 3: 48.0
History data 16: HV BHDM 16 4: 12336.0
History data 16: HV BHDM 16 5: 12336.0
History data 17: HV BHDM 17 1: 48.0
History data 18: HV BHDM 18 1: 48.0
History data 19: HV BHDM 19 1: 48.0
History data 20: HV BHDM 20 1: 48.0
Voltage of hybrid battery after protection: V
Klemme 30:
Battery charge condition: %
Current of high-voltage / hybrid battery: pack current: A
Dynamic limit for charge current: limit for charge current: A
Dynamic limit for discharge current: limit for discharge current: A
Predictive limit for charge current: limit for charge current: A
Predictive limit for discharge current: limit for discharge current: A
Maximum charge level, value: %
Maximum charge level, index 1:
Minimum charge level, value: %
Minimum charge level, index 1:
Maximum voltage for battery cells: V
Maximum voltage for battery cells, index 1:
Minimum voltage for battery cells: V
Minimum voltage for battery cells, index 1:
Battery voltage: sum of voltage of all battery cells: V
Zelle 1: V
Zelle 2: V
Zelle 3: V
Zelle 4: V
Temperature sensor 1: °C
Temperature sensor 2: °C
Temperature sensor 3: °C
Batterietemperatur: °C
Hybrid battery voltage: V
Minimum discharge voltage:
Maximum charging voltage:
Minimum predictive charging voltage:
Minimum predictive discharge voltage:
Minimum dynamic charging voltage:
Minimum dynamic discharge voltage:
Charge state, cell 01: %
Charge state, cell 02: %
Charge state, cell 03: %
Charge state, cell 04: %
Grundeinstellung
Controls
Reset of reversible crash shut-off
Dienstprogramme
Controls
Activating and deactivating all development messages
Handbetrieb
Controls
SFD
Konfiguration