PKW, VW, Golf (AU, BE, BX) USA 2013-, 2020 (L), Saloon , Petrol LDOHC, BD - Hochvolt-Batterielademanagement (BD HOB)
Hochspannungs- batterie - BD - Hochvolt-Batterielademanagement (BD HOB) - 0
Identifikation
ASAM/ODX file identification: EV_HVChargManagVWMQB
ASAM/ODX file version: 003001
Ersatzteilnummer: xxxxxxxxx
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FIN: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware-Teilenummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardware-Version: xxx
Programmierbarkeit: Programmierbar
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Erweiterte Identifikation
ASAM/ODX file identification: EV_HVChargManagVWMQB
ASAM/ODX file version: 003001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nein
Programmability status: flash memory faulty: Nein
Programmability status: communication error: Nein
Programmability status: flash memory not programmable: Nein
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gültig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gültig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gültig
Ausrüstungsnummer: 0
Importer number: 0
Werkstattcode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnosemodus: VW diagnostic
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware-Teilenummer: xxxxxxxxx
Hardware-Version: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Ersatzteilnummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmierbar
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Fehlercode lessen (Normaler Modus)
Controls
Fehlercode löschen
Fehlercode lessen (Aggressiver Modus)
Controls
Fehlercode löschen
Ist-Werte
Actuator test: status: Nicht aktiv
Security access: number of invalid keys, counter: 0
Klemme 30: 4.8 V
Terminal 15:
Terminal 15 status via CAN:
Charging process request:
Max HV DC voltage OBC: 12336 V
Charging status:
High voltage activation request:
Charging connector locking parameter: delocking time lag: 12336 ms
Charging connector locking parameter: locking delay time: 12336 ms
Charging connector locking parameter: delocking request time CAN: 12336 ms
Charging connector locking parameter: locking time lag: 12336 ms
Permission to charge lm: 0
PTC heater current: 0.00 A
Ekk air condition current: 12.00 A
CPU_LOAD: 3 %
ECU reset counter: 151
FuSi appl counter: --
EEPROM debug counter: SM current reset status 8..11: --
EEPROM debug counter: SM old reset status 12..15: --
EEPROM debug counter: debug-BLF 16..30: --
EEPROM debug counter: debug-BLF 0..7: --
EEPROM debug counter: cpu load 31: -- %
EEPROM debug counter: max cpu load 32: -- %
Watchdog reset reason: 00
HV battery charge state: 24.0 %
SOC limits, set by customer: minimum charge level: 48 %
SOC limits, set by customer: maximum charge level: 48 %
Spec. mode, load management:
Max. loading power: 1233600 W
Remote control for charge function of high-voltage battery:
Ready to charge: status charge readiness, engine: Ready for operation
Ready to charge: operational readiness in high-voltage system: Nicht aktiv
Ready to charge: status charge readiness charge management:
Load mode: stat., charge mode:
Load mode: chg. type: Immediate charging
Control signal for power outlet A for battery charging: signal recognized: 0
Control signal for power outlet A for battery charging: current: 1233.6 A
Control signal for power outlet A for battery charging: frequency: 12336 Hz
Control signal for power outlet A for battery charging: control voltage: 12336 mV
Control signal for power outlet A for battery charging: duty cycle: 1233.6 %
Control signal for power outlet B for battery charging: signal recognized: 0
Control signal for power outlet B for battery charging: current: 1233.6 A
Control signal for power outlet B for battery charging: frequency: 12336 Hz
Control signal for power outlet B for battery charging: control voltage: 12336 mV
Control signal for power outlet B for battery charging: duty cycle: 1233.6 %
Cause of cancellation of charge procedure:
Power outlet A for battery charging: status connect. recognition: Nicht erkannt
Power outlet A for battery charging: locking for high-voltage charge plug: Not locked
Power outlet A for battery charging: connector locking requirement: 0
Power outlet A for battery charging: connector unlocking requirement: 0
Power outlet A for battery charging: activation charge cover lock, charge socket A: Verriegeln
Power outlet A for battery charging: status charge cover lock, charge socket A: Verriegelt
Power outlet A for battery charging: activation charge cover unlock, charge socket A: Nicht angefordert
Power outlet A for battery charging: max. current of charge connector: 48 A
Power outlet A for battery charging: charge socket temperature sensor AC: 1178.60 °C
Power outlet A for battery charging: charge sensor temperature sensor DC: 1178.60 °C
Power outlet B for battery charging: status connect. recognition: Nicht erkannt
Power outlet B for battery charging: locking for high-voltage charge plug: Not locked
Power outlet B for battery charging: connector locking requirement: 0
Power outlet B for battery charging: connector unlocking requirement: 0
Power outlet B for battery charging: max. current of charge connector: 48 A
Power outlet B for battery charging: temperarature of charge socket: 1178.60 °C
Power outlet for quick charging of HV battery: status connect. recognition: Nicht erkannt
Button for battery charging: actuation condition: Nicht aktiviert
Button for battery charging: indicator lamp:
Protections for quick charging of HV battery: requirement loader positive terminal: Offen
Protections for quick charging of HV battery: requirement loader negative terminal: Offen
Protections for quick charging of HV battery: status loader positive terminal: Offen
Protections for quick charging of HV battery: status loader negative terminal: Offen
Relay for DC quick charge release: requirement relay: Offen
Relay for DC quick charge release: status relay: Offen
Indicator lamps for power outlet A for battery charging: period duration, indicator light 2: 12336 ms
Indicator lamps for power outlet A for battery charging: period duration, indicator light 3: 12336 ms
Indicator lamps for power outlet A for battery charging: status, indicator light 1:
Indicator lamps for power outlet A for battery charging: status, indicator light 2:
Indicator lamps for power outlet A for battery charging: status, indicator light 3:
Indicator lamps for power outlet A for battery charging: intensity, indicator light 1: 48 %
Indicator lamps for power outlet A for battery charging: intensity, indicator light 2: 48 %
Indicator lamps for power outlet A for battery charging: intensity, indicator light 3: 48 %
Indicator lamps for power outlet A for battery charging: period duration, indicator light 1: 12336 ms
Indicator lamps for power outlet B for battery charging: period duration, indicator light 2: 12336 ms
Indicator lamps for power outlet B for battery charging: period duration, indicator light 3: 12336 ms
Indicator lamps for power outlet B for battery charging: status, indicator light 1:
Indicator lamps for power outlet B for battery charging: status, indicator light 2:
Indicator lamps for power outlet B for battery charging: status, indicator light 3:
Indicator lamps for power outlet B for battery charging: intensity, indicator light 1: 48 %
Indicator lamps for power outlet B for battery charging: intensity, indicator light 2: 48 %
Indicator lamps for power outlet B for battery charging: intensity, indicator light 3: 48 %
Indicator lamps for power outlet B for battery charging: period duration, indicator light 1: 12336 ms
Current at DC charg. stat.: maximum value: 48 A
Current at DC charg. stat.: 48 A
Voltage at DC charg. stat.: maximum value: 12336 V
Voltage at DC charg. stat.: 12336 V
Remaining time for charge procedure: 61680 min
CHAdeMO version: charging station: 48
CHAdeMO version: vehicle: 48
Values from battery mgmt system: max. battery charging voltage: 12336 V
Values from battery mgmt system: battery temperature: -16.00 °C
Values from battery mgmt system: act. voltage HV battery: 3084.00 V
Values from battery mgmt system: act. current HV battery: 2573.00 A
Values from battery mgmt system: A/C requirement:
Values from battery mgmt system: current condition of battery mgmt. system:
Values from battery mgmt system: limit for charge current: 12336 A
Statistics of power outlet A for battery charging: no. of connections: 12336
Statistics of power outlet A for battery charging: no. of lockings: 12336
Statistics of power outlet B for battery charging: no. of connections: 12336
Statistics of power outlet B for battery charging: no. of lockings: 12336
Statistic of DC charger for battery charging: no. of connections: 12336
Statistic of DC charger for battery charging: no. of lockings: 12336
Statistic of DC charger for battery charging: no. of charging process.: 12336
DC charging PLC: minimum current: 1233.6 A
DC charging PLC: actual current: 1233.6 A
DC charging PLC: malfunction status: 48
DC charging PLC: connection status: Nicht vorhanden
DC charging PLC: status: 24
DC charging PLC: maximum voltage: 1233.6 V
DC charging PLC: minimum voltage: 1233.6 V
DC charging PLC: actual voltage: 1233.6 V
DC charging PLC: maximum current: 1233.6 A
Control signal DC charge: control signal 1: 0
Control signal DC charge: control signal 2: 0
Status mains voltage: Nicht vorhanden
Load button: actuation condition: Nicht aktiviert
Load button: indicator lamp:
MAC address: 30 30 30 30 30 30
Number of lockings, charge cover A: no. of lockings: 12336
High-voltage battery charge current: 12081 A
High-voltage battery charge current, target value: 2365.2 A
Stellgliedtest
Controls
Indicator lamps for power outlet A for battery charging
Indicator lamps for power outlet B for battery charging
Indicator light, charge button
Power outlet A for battery charging
Power outlet B for battery charging
Activation charge cover lock charge socket A
Grundeinstellung
Controls
Resetting of all adaptations
Reset counter for locking cycles
Load timer, factory setting
Load profile, factory setting
Dienstprogramme
Controls
XCP
Activation times, plug locking device
Base profile load management
LEDs AC
Statistics of power outlet A for battery charging
Statistics of power outlet B for battery charging
Statistic of DC charger for battery charging
SLAC enable
Number of lockings, charge cover A
Konfiguration
Controls
Konfiguration
Handbetrieb
Controls
SFD
Konfiguration