Bil, VW, Polo, Virtus (BZ) 2018-, 2020 (L), Saloon , Petrol LDOHC, 08 - Air conditioner (08 KLH)
Klima Anlæg - 08 - Air conditioner (08 KLH) - 0
Identifikation
ASAM/ODX file identifikation: EV_AirCondiFrontAU210
ASAM/ODX file version: 005001
Dele nummer: xxxxxxxxx
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
Stel nr.: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware vare nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardwareversion: xxx
Programmerbarhed: Programmerbare
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Advanceret identifikation
ASAM/ODX file identifikation: EV_AirCondiFrontAU210
ASAM/ODX file version: 005001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nej
Programmability status: flash memory faulty: Nej
Programmability status: communication error: Nej
Programmability status: flash memory not programmable: Nej
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gyldig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gyldig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gyldig
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnostisk tilstand: VW diagnose
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware vare nummer: xxxxxxxxx
Hardwareversion: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Dele nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmerbare
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Read DTC (Normal mode)
Controls
Clear DTC
Read DTC (Agressive mode)
Controls
Clear DTC
Levende Data
Terminal 30 : 4.8 V
Terminal 15: Sluk
Terminal 75: Sluk
ECU temperature: 48 °C
Terminal 58d dimmer: 24.0 %
Terminal 58s dimmer: 24.0 %
Drive cycles: 12336
Temperature unit: °C
Stop process prevented: basic setting active: Stop release for start-stop function
Stop process prevented: airflow control deviation: Stop release for start-stop function
Stop process prevented: defrost active: Stop release for start-stop function
Stop process prevented: outside air temperature: Stop release for start-stop function
Stop process prevented: interior control deviation: Stop release for start-stop function
Stop process prevented: window condensation likely: Override of stop for air-conditioning settings
Stop process prevented: temperature setting maximum or minimum: Override of stop for air-conditioning settings
Stop process prevented: stop release for A/C comfort adaptation: Stop release for start-stop function
Stop process prevented: output diagnostic test mode (DTM): Stop release for start-stop function
Start process requested: stop release for A/C comfort adaptation: No restart
Start process requested: maximum stop duration reached: No restart
Start process requested: defrost active: No restart
Start process requested: temperature setting maximum or minimum: No restart
Start process requested: airflow control deviation: No restart
Start process requested: outside air temperature: No restart
Start process requested: interior control deviation: Restart
Start process requested: dew point gradient: Restart
Start process requested: window condensation likely: No restart
Start process requested: humidity inside: No restart
Number of prevented stop processes: window condensation likely: 12336
Number of prevented stop processes: temperature setting maximum or minimum: 12336
Number of prevented stop processes: stop release for A/C comfort adaptation: 12336
Number of prevented stop processes: output diagnostic test mode (DTM): 12336
Number of prevented stop processes: basic setting active: 12336
Number of prevented stop processes: airflow control deviation: 12336
Number of prevented stop processes: defrost active: 12336
Number of prevented stop processes: outside air temperature: 12336
Number of prevented stop processes interior control deviation: 12336
Number of requested start processes: interior control deviation: 12336
Number of requested start processes: dew point gradient: 12336
Number of requested start processes: window condensation likely: 12336
Number of requested start processes: stop release for A/C comfort adaptation: 12336
Number of requested start processes: maximum stop duration reached: 12336
Number of requested start processes: defrost active: 12336
Number of requested start processes: temperature setting maximum or minimum: 12336
Number of requested start processes: airflow control deviation: 12336
Number of requested start processes: outside air temperature: 12336
Start-stop conditions: Stop release
Start-stop enabling: System malfunction
Analysis 1: channel: 111
Analysis 1: value: --
Target value of temperature flap: 1542.0 %
Temperature flap: 1542.0 %
Target value of central air flap motor: 1542.0 %
Central air flap motor: 1542.0 %
Target value of defroster flap: 1542.0 %
Defroster flap: 1542.0 %
Specified value for fresh air/recirc air flow flap: 1542.0 %
Fresh air/recirculation air flow flap: 1542.0 %
Radiator fan 1 activation: 24.0 %
Radiator fan 2 activation: 24.0 %
Compressor shut-off requirement:
Compressor current: 240 mA
Compressor current, target value: 240 mA
Refrigerant pressure: 9.6 bar
Coolant fan activation target value: 19.2 %
Idle speed increase: Sluk
Ambient temperature: -26.0 °C
Right footwell temperature sensor: 1228.6 °C
Temperature after evaporator: -16.0 °C
Interior air temperature: 1193.6 °C
Target blower voltage: 4.8 V
Status of recirculation air: Fresh air
Temperature sensor blower: 768 1/min
Blower voltage: 4.8 V
Supply voltage terminal 30 for actuators: 4.8 V
Supply voltage for external components: 4.8 V
Time since ignition off: hours: 48 Timer
Time since ignition off: minutes: 48 min
A/C compressor torque: -1.0 N·m
Operating hours of A/C: 12336 Timer
Operating hours of A/C compressor: 12336 Timer
Sun sensor light intensity: 1233.6 W/m²
Validity of compressor torque: Gyldig
Front windshield wiper: Ikke aktiv
Enabling for auxiliary heater operation: Sluk
High pressure events in current driving cycle: 16
Counter of compressor activations: 12336
Erase DTC memory counter: 12336
Counter of window condensation events: 12336
Compressor power reduction by engine control module: Not reduced
Counter of compressor switch-offs: 48
Compressor power restriction: No limitation
Switch-on conditions for auxiliary heater: engine running: Nej
Switch-on conditions for auxiliary heater: A/C control active: Nej
Switch-on conditions for auxiliary heater: exterior temperature < 10°C: Nej
Switch-on conditions for auxiliary heater: temperature flap < 80%: Nej
Switch-on conditions for auxiliary heater: diesel: Ja
Switch-on conditions for auxiliary heater: blower voltage > 2.5 V: Ja
Switch-on conditions for auxiliary heater: auxiliary heater allowed via MMI: Nej
Compressor shut-off condition, last:
Compressor shut-off requirement, penultimate:
Compressor shut-off requirement, antepenultimate:
Moisture and temperature sensor, dew point: 1194.1 °C
Moisture and temperature sensor, relative humidity: 24.0 %
Moisture and temperature sensor, temperature: -16.0 °C
Forrudetemperatur: 1194.1 °C
Backup lights: Sluk
Pressing a button: defrost: Sluk
Pressing a button: recirculating air: Sluk
Pressing a button: OFF: Sluk
Pressing a button: AUTO: Tænd
Pressing a button: AC: Sluk
Left push-and-rotary knob counter: 48
Right push-and-rotary knob counter: 48
Energy management deactivation stage: 0
Energy management fan control status: Ikke aktiv
A/C refrigerant pressure sensor: OK
Doors and windows: right rear side window: 48
Doors and windows: sunroof: 48
Doors and windows: driver door: 48
Doors and windows: front passenger door: 48
Doors and windows: left rear door: 48
Doors and windows: right rear door: 48
Doors and windows: driver door side window: 48
Doors and windows: front passenger door side window: 48
Doors and windows: left rear side window: 48
Left front outlet temperature sensor: 1228.6 °C
Left front control code: 8 °C
Left center vent motor: 12336
Target value of left center vent flap motor: 12336
Left center vent motor stop open: 12336
Left center vent motor stop closed: 12336
Left footwell temperature flap motor: 12336
Target value of left footwell temperature flap motor: 12336
Left footwell temperature flap motor stop open: 12336
Left footwell temperature flap motor stop closed: 12336
Defrost flap motor for right side window: 12336
Defrost flap motor for right side window, target value: 12336
Defrost flap motor for right side window stop open: 12336
Defrost flap motor for right side window stop closed: 12336
Right rear specified blowing temperature: -16.0 °C
Back pressure flap motor: 12336
Target value of back pressure flap motor: 12336
Back pressure flap motor stop open: 12336
Back pressure flap motor stop closed: 12336
Driving time remaining for basic setting of compressor run in: 48 sek
Release for consumption recommendation: Nej
Center push-and-rotary knob counter: 48
Kølemiddeltemperatur: -40.50 °C
Motor Hastighed: 0.00 1/min
Køretøjs hastighed : -- km/h
Udgangs test
Controls
Segment test
Left temperature flap motor
Defroster flap motor
Activation A/C compressor
Front fresh air blower
Back pressure door motor
Central air flap motor
Coolant recirculation pump
Coolant fan
MMI display request
Maximum heat output
Maximum cooling capacity
Coolant shut-off valve
Basic setting
Controls
Adapt flap end stops
Compressor run-in and A/C power test
End compressor run-in
Activate blower and flaps
Resetting of all adaptations
Erase counter for start and stop processes
Muligheder
Controls
Analysis 6
Activating and deactivating all development messages
Analysis 9
Analysis 10
Analysis 11
Store recirculation air setting for terminal 15 off
Ignore compressor switch-off by engine control module
Gear ratio of engine - A/C compressor
Temperature clamping after evaporator
Air recirculation when driving in reverse
Fresh air blower voltage offset
Temperature offset, summer operation
Temperature offset, winter operation
Temperature threshold for activation of auxiliary heater
Air recirculation with wipe/wash
Window condensation reduction at high humidity
Leakage air to footwell
Runtime for compressor run-in basic setting
Tolerance range for basic setting of flap end stops
Tolerance range for flap end stops
Blower lowering for slow travel
Blower voltage during compressor run-in
Reset all counters
Stop release for start-stop function
A/C comfort parameter for start-stop function
Window condensation parameter for start-stop function
Production mode
Deactivate production mode
Deactivation of start-stop function
Analysis 12
Blower motor type
Konfiguration
Controls
Konfiguration
Manual mode
Controls
SFD
Konfiguration