Bil, VW, Tayron (0D) 2019-, 2020 (L), Saloon , Diesel VSOHC, 08 - Air conditioner (08 KLH)

Klima Anlæg - 08 - Air conditioner (08 KLH) - 0

Identifikation

ASAM/ODX file identifikation: EV_AirCondiFrontAU210

ASAM/ODX file version: 005001

Dele nummer: xxxxxxxxx

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

Stel nr.: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware vare nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardwareversion: xxx

Programmerbarhed: Programmerbare

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Advanceret identifikation

ASAM/ODX file identifikation: EV_AirCondiFrontAU210

ASAM/ODX file version: 005001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nej

Programmability status: flash memory faulty: Nej

Programmability status: communication error: Nej

Programmability status: flash memory not programmable: Nej

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gyldig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gyldig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gyldig

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostisk tilstand: VW diagnose

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware vare nummer: xxxxxxxxx

Hardwareversion: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Dele nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmerbare

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Levende Data

Terminal 30 : 4.8 V

Terminal 15: Sluk

Terminal 75: Sluk

ECU temperature: 48 °C

Terminal 58d dimmer: 24.0 %

Terminal 58s dimmer: 24.0 %

Drive cycles: 12336

Temperature unit: °C

Stop process prevented: basic setting active: Stop release for start-stop function

Stop process prevented: airflow control deviation: Stop release for start-stop function

Stop process prevented: defrost active: Stop release for start-stop function

Stop process prevented: outside air temperature: Stop release for start-stop function

Stop process prevented: interior control deviation: Stop release for start-stop function

Stop process prevented: window condensation likely: Override of stop for air-conditioning settings

Stop process prevented: temperature setting maximum or minimum: Override of stop for air-conditioning settings

Stop process prevented: stop release for A/C comfort adaptation: Stop release for start-stop function

Stop process prevented: output diagnostic test mode (DTM): Stop release for start-stop function

Start process requested: stop release for A/C comfort adaptation: No restart

Start process requested: maximum stop duration reached: No restart

Start process requested: defrost active: No restart

Start process requested: temperature setting maximum or minimum: No restart

Start process requested: airflow control deviation: No restart

Start process requested: outside air temperature: No restart

Start process requested: interior control deviation: Restart

Start process requested: dew point gradient: Restart

Start process requested: window condensation likely: No restart

Start process requested: humidity inside: No restart

Number of prevented stop processes: window condensation likely: 12336

Number of prevented stop processes: temperature setting maximum or minimum: 12336

Number of prevented stop processes: stop release for A/C comfort adaptation: 12336

Number of prevented stop processes: output diagnostic test mode (DTM): 12336

Number of prevented stop processes: basic setting active: 12336

Number of prevented stop processes: airflow control deviation: 12336

Number of prevented stop processes: defrost active: 12336

Number of prevented stop processes: outside air temperature: 12336

Number of prevented stop processes interior control deviation: 12336

Number of requested start processes: interior control deviation: 12336

Number of requested start processes: dew point gradient: 12336

Number of requested start processes: window condensation likely: 12336

Number of requested start processes: stop release for A/C comfort adaptation: 12336

Number of requested start processes: maximum stop duration reached: 12336

Number of requested start processes: defrost active: 12336

Number of requested start processes: temperature setting maximum or minimum: 12336

Number of requested start processes: airflow control deviation: 12336

Number of requested start processes: outside air temperature: 12336

Start-stop conditions: Stop release

Start-stop enabling: System malfunction

Analysis 1: channel: 111

Analysis 1: value: --

Target value of temperature flap: 1542.0 %

Temperature flap: 1542.0 %

Target value of central air flap motor: 1542.0 %

Central air flap motor: 1542.0 %

Target value of defroster flap: 1542.0 %

Defroster flap: 1542.0 %

Specified value for fresh air/recirc air flow flap: 1542.0 %

Fresh air/recirculation air flow flap: 1542.0 %

Radiator fan 1 activation: 24.0 %

Radiator fan 2 activation: 24.0 %

Compressor shut-off requirement:

Compressor current: 240 mA

Compressor current, target value: 240 mA

Refrigerant pressure: 9.6 bar

Coolant fan activation target value: 19.2 %

Idle speed increase: Sluk

Ambient temperature: -26.0 °C

Right footwell temperature sensor: 1228.6 °C

Temperature after evaporator: -16.0 °C

Interior air temperature: 1193.6 °C

Target blower voltage: 4.8 V

Status of recirculation air: Fresh air

Temperature sensor blower: 768 1/min

Blower voltage: 4.8 V

Supply voltage terminal 30 for actuators: 4.8 V

Supply voltage for external components: 4.8 V

Time since ignition off: hours: 48 Timer

Time since ignition off: minutes: 48 min

A/C compressor torque: -1.0 N·m

Operating hours of A/C: 12336 Timer

Operating hours of A/C compressor: 12336 Timer

Sun sensor light intensity: 1233.6 W/m²

Validity of compressor torque: Gyldig

Front windshield wiper: Ikke aktiv

Enabling for auxiliary heater operation: Sluk

High pressure events in current driving cycle: 16

Counter of compressor activations: 12336

Erase DTC memory counter: 12336

Counter of window condensation events: 12336

Compressor power reduction by engine control module: Not reduced

Counter of compressor switch-offs: 48

Compressor power restriction: No limitation

Switch-on conditions for auxiliary heater: engine running: Nej

Switch-on conditions for auxiliary heater: A/C control active: Nej

Switch-on conditions for auxiliary heater: exterior temperature < 10°C: Nej

Switch-on conditions for auxiliary heater: temperature flap < 80%: Nej

Switch-on conditions for auxiliary heater: diesel: Ja

Switch-on conditions for auxiliary heater: blower voltage > 2.5 V: Ja

Switch-on conditions for auxiliary heater: auxiliary heater allowed via MMI: Nej

Compressor shut-off condition, last:

Compressor shut-off requirement, penultimate:

Compressor shut-off requirement, antepenultimate:

Moisture and temperature sensor, dew point: 1194.1 °C

Moisture and temperature sensor, relative humidity: 24.0 %

Moisture and temperature sensor, temperature: -16.0 °C

Forrudetemperatur: 1194.1 °C

Backup lights: Sluk

Pressing a button: defrost: Sluk

Pressing a button: recirculating air: Sluk

Pressing a button: OFF: Sluk

Pressing a button: AUTO: Tænd

Pressing a button: AC: Sluk

Left push-and-rotary knob counter: 48

Right push-and-rotary knob counter: 48

Energy management deactivation stage: 0

Energy management fan control status: Ikke aktiv

A/C refrigerant pressure sensor: OK

Doors and windows: right rear side window: 48

Doors and windows: sunroof: 48

Doors and windows: driver door: 48

Doors and windows: front passenger door: 48

Doors and windows: left rear door: 48

Doors and windows: right rear door: 48

Doors and windows: driver door side window: 48

Doors and windows: front passenger door side window: 48

Doors and windows: left rear side window: 48

Left front outlet temperature sensor: 1228.6 °C

Left front control code: 8 °C

Left center vent motor: 12336

Target value of left center vent flap motor: 12336

Left center vent motor stop open: 12336

Left center vent motor stop closed: 12336

Left footwell temperature flap motor: 12336

Target value of left footwell temperature flap motor: 12336

Left footwell temperature flap motor stop open: 12336

Left footwell temperature flap motor stop closed: 12336

Defrost flap motor for right side window: 12336

Defrost flap motor for right side window, target value: 12336

Defrost flap motor for right side window stop open: 12336

Defrost flap motor for right side window stop closed: 12336

Right rear specified blowing temperature: -16.0 °C

Back pressure flap motor: 12336

Target value of back pressure flap motor: 12336

Back pressure flap motor stop open: 12336

Back pressure flap motor stop closed: 12336

Driving time remaining for basic setting of compressor run in: 48 sek

Release for consumption recommendation: Nej

Center push-and-rotary knob counter: 48

Kølemiddeltemperatur: -40.50 °C

Motor Hastighed: 0.00 1/min

Køretøjs hastighed : -- km/h

Udgangs test

Controls

Segment test

Left temperature flap motor

Defroster flap motor

Activation A/C compressor

Front fresh air blower

Back pressure door motor

Central air flap motor

Coolant recirculation pump

Coolant fan

MMI display request

Maximum heat output

Maximum cooling capacity

Coolant shut-off valve

Basic setting

Controls

Adapt flap end stops

Compressor run-in and A/C power test

End compressor run-in

Activate blower and flaps

Resetting of all adaptations

Erase counter for start and stop processes

Muligheder

Controls

Analysis 6

Activating and deactivating all development messages

Analysis 9

Analysis 10

Analysis 11

Store recirculation air setting for terminal 15 off

Ignore compressor switch-off by engine control module

Gear ratio of engine - A/C compressor

Temperature clamping after evaporator

Air recirculation when driving in reverse

Fresh air blower voltage offset

Temperature offset, summer operation

Temperature offset, winter operation

Temperature threshold for activation of auxiliary heater

Air recirculation with wipe/wash

Window condensation reduction at high humidity

Leakage air to footwell

Runtime for compressor run-in basic setting

Tolerance range for basic setting of flap end stops

Tolerance range for flap end stops

Blower lowering for slow travel

Blower voltage during compressor run-in

Reset all counters

Stop release for start-stop function

A/C comfort parameter for start-stop function

Window condensation parameter for start-stop function

Production mode

Deactivate production mode

Deactivation of start-stop function

Analysis 12

Blower motor type

Konfiguration

Controls

Konfiguration

Manual mode

Controls

SFD

Konfiguration