Bil, VW, Passat (3G, CB) 2015-, 2016 (G), Wagon, Petrol VSOHC, 22 - 4WD electronics (22 ALR)

4WD - 22 - 4WD electronics (22 ALR) - 0

Identifikation

ASAM/ODX file identifikation: EV_AllWheelContrHA1VW37X

ASAM/ODX file version: 002001

Dele nummer: xxxxxxxxx

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

Stel nr.: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware vare nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardwareversion: xxx

Programmerbarhed: Programmerbare

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Advanceret identifikation

ASAM/ODX file identifikation: EV_AllWheelContrHA1VW37X

ASAM/ODX file version: 002001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nej

Programmability status: flash memory faulty: Nej

Programmability status: communication error: Nej

Programmability status: flash memory not programmable: Nej

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gyldig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gyldig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gyldig

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostisk tilstand: VW diagnose

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware vare nummer: xxxxxxxxx

Hardwareversion: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Dele nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmerbare

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Levende Data

Actuator test: status: Ikke aktiv

Security access: number of invalid keys, counter: 0

Terminal 30 : 4.8 V

Control module temperature: -7 °C

Data logger triggering: Ikke aktiv

Standard - ambient data 1: minutes: 0

Standard - ambient data 1: seconds: 48

Standard - ambient data 1: unlearning counter: 48

Standard - ambient data 1: odometer reading: 3158064 km

Standard - ambient data 1: year: 2012

Standard - ambient data 1: month: 0

Standard - ambient data 1: hours: 3

Standard - ambient data 1: day: 24

Roller test bench mode, functional: Ikke aktiveret

Differential lock Hall sensor 1: 4.8 V

Differential lock Hall sensor 2: 4.8 V

Differential lock status: Hall sensor 1 for differential lock:

Differential lock status: Hall sensor 2 for differential lock:

Differential lock status: switch:

CAN output signal(s) status: emergency running mode: Aktiv

CAN output signal(s) status: status of event memory: Ikke aktiv

CAN output signal(s) status: excess temperature: Aktiv

Analysis 3: exceedance integral 1 traction slip controller: 11

Analysis 3: exceedance integral 2 extreme slip event: --

Analysis 3: undercut integral 3 differential lock too far closed: --

Analysis 4: exeedance intergral 1 traction slip controller: 11

Analysis 4: exeedance intergral 2 extreme slip event: --

Analysis 4: undercut integral 3 differential lock too far closed: --

Upper limit of temperature duration: -- min

Pump calibration values: calibration value at 1 bar voltage last measurement: 12336

Pump calibration values: calibration value at 15 bar pressure EEPROM: 12336

Pump calibration values: calibration value at 15 bar current EEPROM: 12336

Pump calibration values: calibration value at 15 bar current interpolation: 12336

Pump calibration values: calibration value at 15 bar voltage EEPROM: 12336

Pump calibration values: calibration value at 15 bar voltage interpolation: 12336

Pump calibration values: calibration value at 42 bar pressure EEPROM: --

Pump calibration values: calibration value at 42 bar current EEPROM: --

Pump calibration values: calibration value at 42 bar current last measurement: --

Pump calibration values: calibration value at 42 bar voltage EEPROM: --

Pump calibration values: calibration value at 42 bar voltage last measurement: --

Pump calibration values: temperature value at calibration: -- °C

Pump calibration values: series number pump: --

Pump calibration values: calibration value at 1 bar pressure EEPROM: 12336

Pump calibration values: calibration value at 1 bar current EEPROM: 12336

Pump calibration values: calibration value at 1 bar current last measurement: 12336

Pump calibration values: calibration value at 1 bar voltage EEPROM: 12336

Reset tæller: 84

Checksum calculation: --

Left front wheel speed sensor: wheel speed: 1233.6 km/h

Right front wheel speed sensor: wheel speed: 1233.6 km/h

Left rear wheel speed sensor: wheel speed: 1233.6 km/h

Right rear wheel speed sensor: wheel speed: 1233.6 km/h

Cooling fin temperature: -104.31 °C

Duration of overtemperature: 12336 min

Haldex clutch pump current: 12.336 A

Haldex clutch pump PWM signal: 48 %

Haldex clutch pump voltage: 4.8 V

Axle speed deltas: 1233.6 km/h

Clutch temperature: -104.31 °C

Haldex clutch status: degree of blockage: 18.90 %

Udgangs test

Controls

Haldex clutch actuation

Basic setting

Controls

Resetting of all adaptation values

Pumpemotor

Open 4 motion coupling for ignition cycle

Muligheder

Controls

Roller test bench mode, functional

Acoustic measure, wiring logic

Acoustic measure, gasoline

Acoustic measure, diesel

Konfiguration

Controls

Konfiguration

Manual mode

Controls

SFD

Konfiguration