Car, TOYOTA, PROACE , VERSO, BVA AM6 AT6 UDS
Transaxle - BVA AM6 AT6 UDS - 0
Identification
ECU manufacturer: Aisin warner
Equipment number: 98 05 70 92 80
Software version: FF FF
Edition calibration: FF FF
Software reference: --
Part number: --
VIN no: --
Additional number: 98 05 70 92 80
Advanced identification
Part number: 98 05 70 92 80
Additional number: 98 05 70 92 80
Software version: 11 04
DTC
U1208: Invalid data received from ECM
Controls
Clear DTC
Data stream
Oil wear counter: 01 01 01 01
Selector lever position (gear selector switch display): Lever position sensor out of service or not available
Gear engaged: Declutched
Snow mode switch: Pressed
Sport mode switch: Pressed
Torque converter: Not locked up or open
Accelerator pedal position sensor: 64.0 %
Maximum torque: 156 N·m
Engine torque requested by the driver: 200 N·m
Torque reference value requested by the automatic gearbox: 36 N·m
Drain the gearbox automatic: Yes
Request for switching on of an automatic gearbox overheating warning light: No
Check engine telltale: Off
ASR/ESP in regulation mode: No
Main brake switch: Closed
Secondary brake switch: Closed
RCD reawakening: Sleep mode
Changing gear: No
Starter inhibit relay: Authorised
Steering wheel gear shift: Not specified
Front wheels average speed: 2621.0 rpm
Left rear wheel speed sensor: 43.7 km/h
Right rear wheel speed sensor: 21.8 km/h
Front wheels average speed: 26.0 km/h
A/T oil temperature: 88 °C
Battery voltage: 12.80 V
Outside air temperature: 18.5 °C
Engine speed: 0.0 rpm
Actual engine torque: 410 N·m
Engine coolant temperature sensor: 30 °C
Sequence electrovalve 1 status (control): Inactive
Sequence electrovalve 1 status (measured): Active
Sequence electrovalve 2 status (control): Active
Sequence electrovalve 2 status (measured): Inactive
Control current SLU: 2000.0 mA
Return current (measurement) SLU: 30.0 mA
Control current SLT: 100.0 mA
Return current (measurement) SLT: 170.0 mA
Control current SLB1: 10.0 mA
Return current (measurement) SLB1: 160.0 mA
Control current SLC1: 100.0 mA
Return current (measurement) SLC1: 110.0 mA
Control current SLC2: 110.0 mA
Return current (measurement) SLC2: 50 mA
Control current SLC3: 170.0 mA
Return current (measurement) SLC3: 320.0 mA
Control of the adaptation oil pump (start and stop): 51 %
Control of the adaptation oil pump (start and stop): Inactive
A/T input speed: 4080 rpm
A/T input speed calculated: 4080 rpm
A/T output speed: 5504 rpm
A/T output speed (recommended): 64 rpm
Converter sliding speed: 8128.0 rpm
Converter sliding speed (theoretical value): -7040.0 rpm
Automatic gearbox in emergency mode (refuge): No
Intermittent switching to emergency (refuge) mode: No
Declutch when stationary: Not defined
Operating law used by automatic gearbox: Thermal protection 1
Selector lever position: -
Lever locking control (shift - lock): Activated
Key locking control (key - lock): Locked
Starting inhibiting control ( start Lock ): Inactive
Cruise control: Deactivated
Status of the wake-on-Lan line:: Activated
Engine stall: Yes
Read counters
Number of stalling clearing cycles: 5
Counter for clutch protection class 1: 4
Counter for clutch protection class 2: 22
Sequence solenoid valve 1 activations number: 01 01 01 01
Sequence solenoid valve 2 activations number: 00 00 01 01
Clutch solenoid valve C1 activations number: 00 00 00 02
Clutch solenoid valve C2 activations number: 00 00 00 05
Clutch solenoid valve C3 activations number: 00 00 00 00
Brake solenoid valve B1 activations number: 00 00 41 00
Converter lock-up solenoid valve activations number: 00 12 00 02
Gear 1 engagement counter: 00 00 00 01
Gear 2 engagement counter: 00 00 00 02
Gear 3 engagement counter: 00 00 00 03
Gear 4 engagement counter: 00 00 00 04
Gear 5 engagement counter: 00 00 00 05
Gear 6 engagement counter: 00 00 00 06
Reverse gear engagement counter: 00 00 00 07
Neutral engagements counter: 00 00 00 08
Additional oil pump (stop and start) activations number: 00 00 00 08
Vehicle time counter: 00 00 00 00
Actuators test
Controls
Solenoid valve control sequence 1
Solenoid valve control sequence 2
Line pressure modulating valve
Brake B1 pressure modulating valve
Clutch C1 pressure modulating valve
Clutch C2 pressure modulating valve
Clutch C3 pressure modulating valve
Converter lock-up pressure modulating valve
Shift lock solenoid
Start lock
Control of the adaptation oil pump (start and stop)
Utility
Controls
Programming of neutral position
Partial realignment of programmed values
Full realignment of programmed values