Bil, SKODA, Octavia 2020-, 2022 (N), Saloon, estate, Petrol VSOHC, 18 - Additional heater (18 ZST)

Varmer - 18 - Additional heater (18 ZST) - 0

Identifikation

ASAM/ODX file identifikation: EV_AuxilParkiHeateWOS

ASAM/ODX file version: 002001

Dele nummer: xxxxxxxxx

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

Stel nr.: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware vare nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardwareversion: xxx

Programmerbarhed: Programmerbare

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Advanceret identifikation

ASAM/ODX file identifikation: EV_AuxilParkiHeateWOS

ASAM/ODX file version: 002001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nej

Programmability status: flash memory faulty: Nej

Programmability status: communication error: Nej

Programmability status: flash memory not programmable: Nej

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gyldig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gyldig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gyldig

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostisk tilstand: VW diagnose

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware vare nummer: xxxxxxxxx

Hardwareversion: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Dele nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmerbare

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Levende Data

Actuator test: status: Ikke aktiv

Security access: number of invalid keys, counter: 0

Standard - ambient data 1: hours: 3

Standard - ambient data 1: day: 24

Standard - ambient data 1: minutes: 0

Standard - ambient data 1: seconds: 48

Standard - ambient data 1: unlearning counter: 48

Standard - ambient data 1: odometer reading: 3158064 km

Standard - ambient data 1: year: 2012

Standard - ambient data 1: month: 0

Control module switch-off, counter: ECU: --

Heating time limitation: activation function heating timeout: Ikke aktiv

Heating time limitation: heater unlocked, customer service: Ikke aktiv

Heating time limitation: maximum heating time: 48 min

Heating time limitation: remaining running time: 48 min

Heating time limitation: vehicle speed: 123.360 km/h

Heating time limitation: distance traveled: 123.360 m

Overheating counter: 77

Fejlfunktionstæller: 111

Cold heating (EMV-Mode): Sluk

System info CAN: SI_QRS_Mode: Tænd

System info CAN: SI_T_Schutz: Tænd

System info CAN: SI_NWDF: Sluk

System info CAN: SI_BUS_01: Tænd

Terminal info CAN: ZAS_Kl_S: Sluk

Terminal info CAN: ZAS_Kl_15: Sluk

Terminal info CAN: MO_Kl_50: Sluk

Terminal info CAN: MO_StartStopp_Motor_Stopp: Sluk

Terminal info CAN: MO_StartStopp_Motor_Wiederstart: Tænd

E85 level CAN: 840.0 %

Air pressure CAN: 664.8 mbar

CAN error bits: motor_12_alt: Sluk

CAN error bits: clima_sensor_02_alt: Sluk

CAN error bits: uhrzeit_01_alt: Sluk

CAN error bits: combi_02_alt: Sluk

CAN error bits: ESP_21_alt: Tænd

CAN error bits: clima_11_alt: Tænd

Fuel warning CAN: KBI_Tankwarnung: Sluk

Fuel warning CAN: KBI_Inhalt_Tank: 48 L

Clima signals CAN: KL_Zuheizer_Freigabe: Sluk

Clima signals CAN: KL_STL_aktiv: Sluk

Clima signals CAN: KL_STH_aktiv: Sluk

Clima signals CAN: KL_Magnetventil: Sluk

Clima signals CAN: KL_WaPu: Tænd

Clima signals CAN: KL_Heizkreisventilstellung: Valve position correct

Clima signals CAN: KL_STH_Betriebsdauer: 48 min

Thermo managment CAN:

BEM turn on prohibition CAN: Sluk

BEM turn off step CAN:

Crash signal CAN:

Target time programming CAN: KL_ZZ_month: 48 Mon

Target time programming CAN: KL_ZZ_day: 48 days

Target time programming CAN: KL_ZZ_hour: 48 Timer

Target time programming CAN: KL_ZZ_minute: 48 min

Target time programming CAN: KL_ZZ_status_timer: Sluk

Target time programming CAN: KL_ZZ_operating_mode: 48

STH signals CAN: STH_LED: Sluk

STH signals CAN: STH_Zusatzheizung: Sluk

STH signals CAN: STH_Geblaese: Sluk

STH signals CAN: STH_Pumpe_Ein: Sluk

STH signals CAN: STH_EKP_Anst: Tænd

STH signals CAN: STH_Funk_ein: Tænd

STH signals CAN: STH_Funk_aus: Sluk

STH signals CAN: STH_Ventil_Status: Sluk

STH signals CAN: STH_war_aktiv: Sluk

STH signals CAN: STH_Motorvorwaermung: Sluk

STH signals CAN: STH_Servicemode: Sluk

STH signals CAN: STH_KD_Fehler: Sluk

STH signals CAN: STH_KVS_Ueberlauf: Tænd

STH signals CAN: STH_Abschaltstufe: Tænd

STH signals CAN: STH_Transport_Mode: Sluk

STH signals CAN: STH_Waermeeintrag: 48 min

STH signals CAN: STH_Ventiloeffnungszeit: 48 min

STH signals CAN: STH_Heizleistung: 960 W

STH signals CAN: STH_Fehlerstatus: Ingen fejl

STH signals CAN: STH_Texte:

STH signals CAN: STH_Fehler_ElWaPu: Sluk

STH signals CAN: STH_Pumpen_Anf_extern: Sluk

STH signals CAN: STH_SNI: 30

Internal function state:

Auxiliary heater request with engine preheating: Ikke aktiv

Development data on CAN: Ikke aktiv

Data record: 00000000000

BEM battery error: Sluk

BEM generator error:

Battery charge condition:

Undervoltage threshold constant value: 4.8 V

Undervoltage mode: Internal

Operating mode:

Transfer fuel pump: activation: Sluk

Transfer fuel pump: return message: Sluk

Combustion air blower: 12336 1/min

Glow plug with flame monitoring, activation: 24.0 %

Glow plug with flame monitoring: 12.336 Ohm

Metering pump: 2.40 Hz

Recirculation pump: water pump request for parking heater through thermomanagement: Nej

Recirculation pump: water pump request for parking heater through engine: Nej

Recirculation pump:

Recirculation pump: 12.336 V

Recirculation pump: maximum wait time: 12336 sek

Recirculation pump: remaining run time for pump run-on: 12336 sek

Switch-on conditions for auxiliary heater: terminal 15: Ikke aktiv

Switch-on conditions for auxiliary heater: A/C request, auxiliary heat mode: Ikke aktiv

Switch-on conditions for auxiliary heater: engine running status: Not recognized

Switch-on conditions for auxiliary heater: coolant temperature: Limiting values exceeded

Switch-on conditions for auxiliary heater: outside air temperature: OK

Switch-on conditions for auxiliary heater: transport mode: Aktiv

Switch-on conditions for auxiliary heater: static current measuring mode: Ikke aktiv

Switch-on conditions for auxiliary heater: roller test bench mode, functional: Ikke aktiv

Switch-on conditions for auxiliary heater: heater unit locked: Not locked

Switch-on conditions for auxiliary heater: fault that prevents starting: Ikke aktiv

Switch-on conditions for auxiliary heater: start of operations: Not recognized

Switch-on conditions for auxiliary heater: auxiliary heat.: Ikke understøttet

Reasons for auxil. heat inhibit: actuation inhibited by energy management: Ikke aktiv

Reasons for auxil. heat inhibit: switch-off due to energy management: Ikke aktiv

Reasons for auxil. heat inhibit: internal undervoltage: Not recognized

Reasons for auxil. heat inhibit: generator failure: Ikke aktiv

Reasons for auxil. heat inhibit: battery malfunction: Aktiv

Reasons for auxil. heat inhibit: ethanol content in fuel: OK

Reasons for auxil. heat inhibit: fuel level: OK

Reasons for auxil. heat inhibit: vehicle elec. system overload: Ikke aktiv

Actuation conditions for auxiliary heater: A/C request, parking heat mode: Ikke aktiv

Actuation conditions for auxiliary heater: transport mode: Ikke aktiv

Actuation conditions for auxiliary heater: static current measuring mode: Ikke aktiv

Actuation conditions for auxiliary heater: roller test bench mode, functional: Ikke aktiv

Actuation conditions for auxiliary heater: heater unit locked: Låst

Actuation conditions for auxiliary heater: fault that prevents starting: Aktiv

Actuation conditions for auxiliary heater: start of operations: Not recognized

Actuation conditions for auxiliary heater: parking heat: Ikke understøttet

Reasons for parking heat inhibit: actuation inhibited by energy management: Ikke aktiv

Reasons for parking heat inhibit: switch-off due to energy management: Ikke aktiv

Reasons for parking heat inhibit: internal undervoltage: Not recognized

Reasons for parking heat inhibit: generator failure: Ikke aktiv

Reasons for parking heat inhibit: battery malfunction: Aktiv

Reasons for parking heat inhibit: ethanol content in fuel: OK

Reasons for parking heat inhibit: fuel level: OK

Reasons for parking heat inhibit: vehicle elec. system overload: Ikke aktiv

Auxiliary/parking heater functions: auxiliary heating: Not possible

Auxiliary/parking heater functions: parking heating: Not possible

Auxiliary/parking heater functions: ventilation: Not possible

Ambient temperature: outside air temperature raw value (unfiltered): -26.0 °C

Ambient temperature: outside temperature displayed value: -26.0 °C

Ambient temperature: value used: -26.0 °C

Ambient temperature: status: Filtered

Ambient temperature: vehicle speed: 123.36 km/h

Remote control: RF transmitter signal:

Remote control: receiver status:

Remote control: quality of signal last received: 48

Heater operating data: actuation counter, auxiliary heater: 12336

Heater operating data: fuel consumption: 808464.432 L

Heater operating data: burn time: 12336 Timer

Heater operating data: burn time: 48 min

Heater operating data: activation duration: 12336 Timer

Heater operating data: 48 min

Heater operating data: actuation counter, parking heater: 12336

System runtime in current combustion mode: operating time: 48 min

System runtime in current combustion mode: activation duration: 48 min

System runtime in current combustion mode: remaining running time: 48 min

System runtime in current combustion mode: timer for minimum burn time: 12336 sek

Cut-off requirements, last:

Cut-off requirements, second to last:

Cut-off requirements, third to last:

Cut-off requirements, fourth to last:

First-time operation status: fuel line filling: Nej

First-time operation status: system test: Nej

First-time operation status: timer for fuel line filling: 48 sek

Flame generation: Not recognized

Heater unit, reason locked:

Fuel tank level: 48 L

Actuation signal for parking heater:

Radio-frequency transmitter: ID sensor 3: 30 30 30

Radio-frequency transmitter: ID sensor 4: 30 30 30

Radio-frequency transmitter: number of transmitters adapted: 48

Radio-frequency transmitter: ID sensor 1: 30 30 30

Radio-frequency transmitter: ID sensor 2: 30 30 30

Adapting RF transmitter:

External pump for coolant circulation (engine): activation: Sluk

External pump for coolant circulation (engine): return message: 48 %

External pump for coolant circulation (engine): time: 12336 sek

Coolant change-over valve:

Switch-over valve for coolant, target value: 24.0 %

Heater fuel type:

Heater fuel type: engine fuel type:

Heater fuel type: type of fuel:

Reason for blocking remote control: actuation inhibited by energy management: Ikke aktiv

Reason for blocking remote control: switch-off due to energy management: Ikke aktiv

Reason for blocking remote control: internal undervoltage: Not recognized

Reason for blocking remote control: ethanol content in fuel: Limiting values exceeded

Reason for blocking remote control: fuel level: Fuel supply low

Reason for blocking remote control: heating timeout: Aktiv

Kølemiddeltemperatur: -2 °C

Motor Hastighed: 12336 1/min

Fresh air blower: Sluk

Fresh air blower maximum wait time: 12336 sek

Coolant temperature parking heater: -2 °C

Operating condition of parking heater: operating condition:

Operating condition of parking heater: heater output: 24.0 %

Operating data of recirc. pump: total run time: 12336 Timer

Operating data of recirc. pump: operating time total: 48 min

Operating data of recirc. pump: run time since repl.: 12336 Timer

Operating data of recirc. pump: operating time since replacement: 48 min

Batteri spænding: 12.336 V

Udgangs test

Controls

Recirculation pump

Combustion air blower

Glow plug with flame monitoring

Metering pump

Front fresh air blower

Coolant change-over valve

Transfer fuel pump

Basic setting

Controls

Resetting of all adaptations

Heater unlock

Fuel line filling

Glow plug replace

Heater operation for production

Heater operation for customer service

Adapting RF transmitter via barcode

Adapting RF transmitter

Heating shut off

Replace recirculation pump

Unlock heating device

Muligheder

Controls

Activation of simulated flamme run for EMV measuring

Insufficient voltage threshold

CO2 adjustment

Auxiliary heater activation

Low voltage detection, time limit

Auxiliary heat control parameters

Parking heat control parameters

Note request for auxiliary heater from A/C system

Coolant change-over valve

Recirculation pump

Evaluate ethanol content

Evaluate air pressure via CAN

Initial brændstof påfyldning

Minimum burn time

Transfer fuel pump

Development data on CAN

EEPROM address

Access EEPROM value

Recirculation pump locking mechan.

Control module switch-off, switch-off time

Heating time limitation

Konfiguration

Controls

Konfiguration

Manual mode

Controls

SFD

Konfiguration