Bil, RENAULT, DUSTER, Transmission control module (BVA)
transakse - Transmission control module (BVA) - 0
Identifikation
Program number: 01 04
Softwareversion: 00 00
Kalibreringsnummer: 00 00
MPR reference: 82 00 13 89 52
Electronic version: 61 00 95 02 00
Diagnose version: 08
Supplier: 219
Stel nr.: VF1BG0W0A29195448
Transmission oil drain date:
Oil wear counter:
Read date of last after sales operation:
Fejlkoder
DF177 [DEF]: Transmission overheat - circuit high voltage
Controls
Clear DTC
Levende Data
ECU supply voltage: 0.0 V
Change down request: Inaktiv
Multifunction switch P/N: Aktiv
Multifunction switch S2: Aktiv
Multifunction switch S3: Aktiv
Multifunction switch S4: Inaktiv
Fault warning light control: Aktiv
Oil too hot information: Nej
Solenoid valve supply: Missing
Reduktion af drejningsmoment: Inaktiv
Exchanger flow control solenoid valve: Inaktiv
Lever locking electromagnet control: Inaktiv
Solenoid valve control sequence 1: Inaktiv
Solenoid valve control sequence 2: Inaktiv
Solenoid valve control sequence 3: Inaktiv
Solenoid valve control sequence 4: Inaktiv
Solenoid valve control sequence 5: Inaktiv
Solenoid valve control sequence 6: Inaktiv
Rough pedal position: -- %
Manual mode: --
Snow mode: --
Stop contact (close): --
Stop contact (open): --
Lever position: --
Beregnet motordrejningsmoment: -- N·m
Køretøjs hastighed : -- km/h
Torque converter: --
Turbine speed/Engine speed difference: -- Omdr.
Reference pressure: 0.0 bar
Oil pressure: 0.0 bar
Transmission oil temperature: -50 °C
Motor Hastighed: 0 Omdr.
Turbine speed: 0 Omdr.
Standard pedal position: 0.0 %
Gaspedalposition: 0 %
Motor kølevæske temperatur føler: -50 °C
Motordrejningsmoment: -100 N·m
Initial ratio: Frigear
Udgangs test
Controls
Actuators sequential control
Selector lever locking electromagnet
Solenoid valve control sequence 1
Solenoid valve control sequence 2
Solenoid valve control sequence 3
Solenoid valve control sequence 4
Solenoid valve control sequence 5
Solenoid valve control sequence 6
Modulation solenoid valve
Converter lock-up solenoid valve
Selector lever locking electromagnet
Heat exchanger output solenoid valve
Muligheder
Controls
V009 Write date of last after sales operation
V016 Write transmission oil change date
V001 Rediger stel nr.
V015 Note oil wear counter
R005 Auto-adaptives