Car, AUDI, A3 2013-, 2015 (F), Saloon, 4-door, CLHA 1,6l TDI , 77kW, C6 - Battery charger control module (C6 HBL)
Power source control - C6 - Battery charger control module (C6 HBL) - 0
Identification
ASAM/ODX file identification: EV_OBCTwoPhaseDT2AU736
ASAM/ODX file version: 006001
Part number: xxxxxxxxx
Equipment number: 0
Importer number: 0
Workshop code: 0
VIN no: xxxxxxxxxxxxxxxxx
Software version: xxxx
Hardware part number: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardware version: xxx
Programmability: Programmable
Program consistency: Program present
System abbreviation: xxxx
Engine: CJTA
Advanced identification
ASAM/ODX file identification: EV_OBCTwoPhaseDT2AU736
ASAM/ODX file version: 006001
Software version: xxxx
Engine: CJTA
Programmability status: error in flash memory: No
Programmability status: flash memory faulty: No
Programmability status: communication error: No
Programmability status: flash memory not programmable: No
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Valid
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Valid
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Valid
Equipment number: 0
Importer number: 0
Workshop code: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnostic mode: VW diagnostic
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware part number: xxxxxxxxx
Hardware version: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Part number: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmable
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Read DTC (Normal mode)
Controls
Clear DTC
Read DTC (Agressive mode)
Controls
Clear DTC
Data stream
Actuator test: status: Not active
Security access: number of invalid keys, counter: 0
Terminal 30: 4.8 V
Data logger triggering:
Standard - ambient data 1: hours: 3
Standard - ambient data 1: day: 24
Standard - ambient data 1: minutes: 0
Standard - ambient data 1: seconds: 48
Standard - ambient data 1: unlearning counter: 48
Standard - ambient data 1: odometer reading: 3158064 km
Standard - ambient data 1: year: 2012
Standard - ambient data 1: month: 0
Charging process request:
Charging status:
High voltage activation request:
Rail energy transformation: rail 1 energy transformation: 315806.4 kWh
Rail energy transformation: rail 2 energy transformation: 315806.4 kWh
Rail energy transformation: rail 3 energy transformation: 315806.4 kWh
Charging connector locking parameter: delocking time lag: 123360 ms
Charging connector locking parameter: locking delay time: 123360 ms
Charging connector locking parameter: delocking request time CAN: 123360 ms
Charging connector locking parameter: locking time lag: 123360 ms
Permission to charge lm: 0.00
PTC heater current: 0.0 A
Ekk air condition current: 12.0 A
Prx voltage charging connector A: 12336 mV
Temperature battery charger coolplate: 8 °C
History data life time: charger coolant temperature greater 30 deg: 12336 hours
History data life time: charger coolant temperature greater 40 deg: 12336 hours
History data life time: charger coolant temperature greater 50 deg: 12336 hours
History data life time: charger coolant temperature greater 60 deg: 12336 hours
History data life time: charger coolant temperature greater 70 deg: 12336 hours
History data life time: charger coolant temperature greater 80 deg: 12336 hours
History data life time: counter error plug interlock: 48 Counts
History data life time: counter timer charging: -- Counts
History data life time: energy meter rail1: 3158064 kWh
History data life time: energy meter rail2: 3158064 kWh
History data life time: charger coolant temperature avg lifetime: -16.0 °C
HVLM error status:
AWC control values: HVLM AWC target mode:
AWC values: AWC status:
HVLM LED state:
HVLM Ladesystemhinweise:
Stop management system, developer values: HVLM request HMS:
Stop management system, developer values: HVLM parking maintained HMS:
Thermomanagementsystem Entwicklerwerte: TME Heizstrategie:
HVLM signals conditioning: TME heating strategy:
HVLM signals conditioning:
Current voltage protection:
Warning status battery charger:
Temperature battery charger system board: 8 °C
Temperature battery charger PFC coil: 8 °C
Temperature DC/DC coil: 8 °C
Error status battery charger:
Operating condition charge unit:
Function limitation charging due to temperarature charge socket: Not active
Function limitation charging due to temperarature charge unit:
Target operating condition charge unit:
Values from battery mgmt system: current condition of battery mgmt. system:
Charger cooling requirement:
Spec. mode, load management:
Max. loading power: 308400 W
Remote control for charge function of high-voltage battery:
Load mode: stat., charge mode:
Load mode: chg. type: Immediate charging
Control signal for power outlet A for battery charging: signal recognized: 0.00
Control signal for power outlet A for battery charging: current: 1233.6 A
Control signal for power outlet A for battery charging: frequency: 12336 Hz
Control signal for power outlet A for battery charging: control voltage: 12336.0 mV
Control signal for power outlet A for battery charging: duty cycle: 1233.6 %
Cause of cancellation of charge procedure:
Power outlet A for battery charging: activation charge cover unlock, charge socket A: Not requested
Power outlet A for battery charging: status charge cover lock, charge socket A: Not locked
Power outlet A for battery charging: activation charge cover lock, charge socket A: Not requested
Power outlet A for battery charging: connector unlocking requirement: 1.00
Power outlet A for battery charging: connector locking requirement: 1.00
Power outlet A for battery charging: locking for high-voltage charge plug: Not locked
Power outlet A for battery charging: status connect. recognition: Not present
Power outlet A for battery charging: max. current of charge connector: 48 A
Power outlet A for battery charging: charge socket temperature sensor AC: 1178.6 °C
Power outlet A for battery charging: charge sensor temperature sensor DC: 1178.6 °C
Power outlet B for battery charging: status charge cover lock, charge socket B: Not locked
Power outlet B for battery charging: activation charge cover lock, charge socket B: Not requested
Power outlet B for battery charging: connector unlocking requirement: 1.00
Power outlet B for battery charging: connector locking requirement: 1.00
Power outlet B for battery charging: locking for high-voltage charge plug: Not locked
Power outlet B for battery charging: status connect. recognition: Not present
Power outlet B for battery charging: max. current of charge connector: 48 A
Power outlet B for battery charging: temperarature of charge socket: 1178.6 °C
Power outlet for quick charging of HV battery: status connect. recognition: Not present
Button for battery charging: actuation condition: Not activated
Button for battery charging: indicator lamp:
Protections for quick charging of HV battery: status loader negative terminal: Closed
Protections for quick charging of HV battery: status loader positive terminal: Closed
Protections for quick charging of HV battery: requirement loader negative terminal: Open
Protections for quick charging of HV battery: requirement loader positive terminal: Open
Relay for DC quick charge release: status relay: Open
Relay for DC quick charge release: requirement relay: Open
Indicator lamps for power outlet A for battery charging: intensity, indicator light 4: 48 %
Indicator lamps for power outlet A for battery charging: period duration, indicator light 1: 12336 ms
Indicator lamps for power outlet A for battery charging: period duration, indicator light 2: 12336 ms
Indicator lamps for power outlet A for battery charging: period duration, indicator light 3: 12336 ms
Indicator lamps for power outlet A for battery charging: period duration, indicator light 4: 12336 ms
Indicator lamps for power outlet A for battery charging: status, indicator light 1:
Indicator lamps for power outlet A for battery charging: status, indicator light 2:
Indicator lamps for power outlet A for battery charging: status, indicator light 3:
Indicator lamps for power outlet A for battery charging: status, indicator light 4:
Indicator lamps for power outlet A for battery charging: intensity, indicator light 1: 48 %
Indicator lamps for power outlet A for battery charging: intensity, indicator light 2: 48 %
Indicator lamps for power outlet A for battery charging: intensity, indicator light 3: 48 %
Indicator lamps for power outlet B for battery charging: intensity, indicator light 4: 48 %
Indicator lamps for power outlet B for battery charging: period duration, indicator light 1: 12336 ms
Indicator lamps for power outlet B for battery charging: period duration, indicator light 2: 12336 ms
Indicator lamps for power outlet B for battery charging: period duration, indicator light 3: 12336 ms
Indicator lamps for power outlet B for battery charging: period duration, indicator light 4: 12336 ms
Indicator lamps for power outlet B for battery charging: status, indicator light 1:
Indicator lamps for power outlet B for battery charging: status, indicator light 2:
Indicator lamps for power outlet B for battery charging: status, indicator light 3:
Indicator lamps for power outlet B for battery charging: status, indicator light 4:
Indicator lamps for power outlet B for battery charging: intensity, indicator light 1: 48 %
Indicator lamps for power outlet B for battery charging: intensity, indicator light 2: 48 %
Indicator lamps for power outlet B for battery charging: intensity, indicator light 3: 48 %
Current at DC charg. stat.: maximum value: 48 A
Current at DC charg. stat.: 48 A
Voltage at DC charg. stat.: maximum value: 12336.0 V
Voltage at DC charg. stat.: 12336.0 V
Remaining time for charge procedure: 61680 min
CHAdeMO version: charging station: 48
CHAdeMO version: vehicle: 48
Statistics of power outlet A for battery charging: no. of connections: 12336
Statistics of power outlet A for battery charging: no. of lockings: 12336
Statistics of power outlet B for battery charging: no. of connections: 12336
Statistics of power outlet B for battery charging: no. of lockings: 12336
Statistic of DC charger for battery charging: no. of connections: 12336
Statistic of DC charger for battery charging: no. of lockings: 12336
Statistic of DC charger for battery charging: no. of charging process.: 12336
DC charging PLC: minimum current: 1233.6 A
DC charging PLC: actual current: 1233.6 A
DC charging PLC: malfunction status: 48
DC charging PLC: connection status: Not present
DC charging PLC: maximum voltage: 1233.6 V
DC charging PLC: minimum voltage: 1233.6 V
DC charging PLC: actual voltage: 1233.6 V
DC charging PLC: maximum current: 1233.6 A
Control signal DC charge: control signal 2: 0.00
Control signal DC charge: control signal 1: 0.00
Holding management system:
Charging station: vehicle error: No error
Charging station: error du to incompatible HV battery: Error
Charging station: charging station error: Error
Charging station: charging station status: Standby
Charging station: charging plug condition locked: No error
Status mains voltage: Not present
Load button: actuation condition: Not activated
Load button: indicator lamp:
Load button: locating illumination charge button:
Number of lockings, charge cover A: no. of lockings: 12336
Charging unit working mode: charging module 1:
Charging unit working mode: charging module 2:
Charging unit working mode: charging module 3:
Status of voltage freedom:
Charging lid lock activation time: 48 sec
Control module switch-off, counter: ECU:
Control module switch-off, counter: data bus:
Max HV DC voltage OBC:
AC network separated frequency: AC rail 1 network frequency: 48.8 Hz
AC network separated frequency: AC rail 2 network frequency: 48.8 Hz
AC network separated frequency: AC rail 3 network frequency: 48.8 Hz
Charger coolant temperature 2: 8 °C
Bulk voltage: bulk 1:
Bulk voltage: bulk 2:
Bulk voltage: bulk 3:
AWC control values: HVLM AWC target current:
AWC values: AWC MaxLadLeistung:
AC maximum input current value: 1.0 A
Power efficiency: 79.8 %
Power loss battery charger: 960 W
Charger coolant temperature: 8 °C
HV charger, current output voltage:
AC line current: 4.8 A
Values from battery mgmt system: maximum battery voltage:
Values from battery mgmt system: HV battery state of charge:
Values from battery mgmt system: act. voltage HV battery:
Values from battery mgmt system: act. current HV battery:
Values from battery mgmt system: limit for charge current:
Charging station: max. charge voltage DC charge station:
DC-output voltage, actual value per module: charging module 1:
DC-output voltage, actual value per module: charging module 2:
DC-output voltage, actual value per module: charging module 3:
DC-output current, actual value per module: charging module 1:
DC-output current, actual value per module: charging module 2:
DC-output current, actual value per module: charging module 3:
AC-network current, actual value per module: charging module 1: 4.8 A
AC-network current, actual value per module: charging module 2: 4.8 A
AC-network current, actual value per module: charging module 3: 4.8 A
AC-network voltage, actual value per phase: phase 1:
AC-network voltage, actual value per phase: phase 2:
AC-network voltage, actual value per phase: phase 3:
High-voltage battery charge current:
High-voltage battery charge current, target value:
Voltage terminal 30 battery data module: 7.4 V
Max. battery charging voltage:
HV battery voltage:
Voltage low voltage side DC/DC - converter: 4.8 V
Actuators test
Controls
Power outlet A for battery charging
Power outlet B for battery charging
Indicator lamps for power outlet A for battery charging
Indicator lamps for power outlet B for battery charging
Activation charge cover lock charge socket A
Activation charge cover lock charge socket B
Activation of LED module chrg. button
Basic setting
Controls
Resetting of all adaptations
Load timer, factory setting
Load profile, factory setting
Reset counter for locking cycles
Utility
Controls
Production mode
Deactivate production mode
Base profile load management
LEDs AC/DC
Activation times, plug locking device
Statistics of power outlet A for battery charging
Statistics of power outlet B for battery charging
Statistic of DC charger for battery charging
Number of lockings, charge cover A
Control module switch-off, switch-off time
Activating and deactivating all development messages
Configuration
Controls
Configuration
Manual mode
Controls
SFD
Configuration