PKW, AUDI, A4 2016-, 2020 (L), Allroad, DECA 2.9l TFSI , 331kW, CC - Startergenerator (CC STG)

Stromversorgungs- steuerung - CC - Startergenerator (CC STG) - 0

Identifikation

ASAM/ODX file identification: EV_Start48VAU651

ASAM/ODX file version: 001001

Ersatzteilnummer: xxxxxxxxx

Ausrüstungsnummer: 0

Importer number: 0

Werkstattcode: 0

FIN: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware-Teilenummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardware-Version: xxx

Programmierbarkeit: Programmierbar

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Erweiterte Identifikation

ASAM/ODX file identification: EV_Start48VAU651

ASAM/ODX file version: 001001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nein

Programmability status: flash memory faulty: Nein

Programmability status: communication error: Nein

Programmability status: flash memory not programmable: Nein

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gültig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gültig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gültig

Ausrüstungsnummer: 0

Importer number: 0

Werkstattcode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnosemodus: VW diagnostic

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware-Teilenummer: xxxxxxxxx

Hardware-Version: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Ersatzteilnummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmierbar

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Fehlercode lessen (Normaler Modus)

Controls

Fehlercode löschen

Fehlercode lessen (Aggressiver Modus)

Controls

Fehlercode löschen

Ist-Werte

Actuator test: output control status: Nicht aktiv

History data 1: parameter 4: 3158064.0

History data 1: parameter 5: 19.20 %

History data 1: parameter 6: 19.20 %

History data 1: parameter 7: 19.20 %

History data 1: parameter 8: 19.20 %

History data 1: parameter 9: 19.20 %

History data 1: parameter 10: 19.20 %

History data 1: parameter 11: 19.20 %

History data 1: parameter 12: 19.20 %

History data 1: parameter 13: 19.20 %

History data 1: parameter 14: 19.20 %

History data 1: parameter 15: -- %

History data 1: parameter 16: --

History data 1: parameter 17: --

History data 1: parameter 18: --

History data 1: parameter 19: -- sec

History data 1: parameter 20: -- sec

History data 1: parameter 21: -- sec

History data 1: parameter 1:

History data 1: parameter 2: 3158064.0

History data 1: parameter 3: 3158064 sec

History data 2: parameter 8: 3600 W

History data 2: parameter 9: 3600 W

History data 2: parameter 10: 3600 W

History data 2: parameter 11: 3600 W

History data 2: parameter 12: 3600 W

History data 2: parameter 13: 3600 W

History data 2: parameter 14: 3600 W

History data 2: parameter 15: 3600 W

History data 2: parameter 16: 3600 W

History data 2: parameter 1: 3600 W

History data 2: parameter 2: 3600 W

History data 2: parameter 3: 3600 W

History data 2: parameter 4: 3600 W

History data 2: parameter 5: 3600 W

History data 2: parameter 6: 3600 W

History data 2: parameter 7: 3600 W

History data 3: parameter 8: 3600 W

History data 3: parameter 9: 3600 W

History data 3: parameter 10: 3600 W

History data 3: parameter 11: 3600 W

History data 3: parameter 12: 3600 W

History data 3: parameter 13: 3600 W

History data 3: parameter 14: 3600 W

History data 3: parameter 15: 3600 W

History data 3: parameter 16: 3600 W

History data 3: parameter 1: 3600 W

History data 3: parameter 2: 3600 W

History data 3: parameter 3: 3600 W

History data 3: parameter 4: 3600 W

History data 3: parameter 5: 3600 W

History data 3: parameter 6: 3600 W

History data 3: parameter 7: 3600 W

History data 4: parameter 8: 24.00 %

History data 4: parameter 9: 24.00 %

History data 4: parameter 10: 24.00 %

History data 4: parameter 11: 24.00 %

History data 4: parameter 12: 24.00 %

History data 4: parameter 13: 24.00 %

History data 4: parameter 14: 24.00 %

History data 4: parameter 15: 24.00 %

History data 4: parameter 16: 24.00 %

History data 4: parameter 1: 24.00 %

History data 4: parameter 2: 24.00 %

History data 4: parameter 3: 24.00 %

History data 4: parameter 4: 24.00 %

History data 4: parameter 5: 24.00 %

History data 4: parameter 6: 24.00 %

History data 4: parameter 7: 24.00 %

History data 5: parameter 8: 24.00 %

History data 5: parameter 9: 24.00 %

History data 5: parameter 10: 24.00 %

History data 5: parameter 1: 24.00 %

History data 5: parameter 2: 24.00 %

History data 5: parameter 3: 24.00 %

History data 5: parameter 4: 24.00 %

History data 5: parameter 5: 24.00 %

History data 5: parameter 6: 24.00 %

History data 5: parameter 7: 24.00 %

History data 6: parameter 8: 24.00 %

History data 6: parameter 9: 24.00 %

History data 6: parameter 10: 24.00 %

History data 6: parameter 1: 24.00 %

History data 6: parameter 2: 24.00 %

History data 6: parameter 3: 24.00 %

History data 6: parameter 4: 24.00 %

History data 6: parameter 5: 24.00 %

History data 6: parameter 6: 24.00 %

History data 6: parameter 7: 24.00 %

History data 7: parameter 8: 24.00 %

History data 7: parameter 9: 24.00 %

History data 7: parameter 10: 24.00 %

History data 7: parameter 1: 24.00 %

History data 7: parameter 2: 24.00 %

History data 7: parameter 3: 24.00 %

History data 7: parameter 4: 24.00 %

History data 7: parameter 5: 24.00 %

History data 7: parameter 6: 24.00 %

History data 7: parameter 7: 24.00 %

History data 8: parameter 8: 24.00 %

History data 8: parameter 9: 24.00 %

History data 8: parameter 10: 24.00 %

History data 8: parameter 1: 24.00 %

History data 8: parameter 2: 24.00 %

History data 8: parameter 3: 24.00 %

History data 8: parameter 4: 24.00 %

History data 8: parameter 5: 24.00 %

History data 8: parameter 6: 24.00 %

History data 8: parameter 7: 24.00 %

History data 9: parameter 8: 24.00 %

History data 9: parameter 9: 24.00 %

History data 9: parameter 10: 24.00 %

History data 9: parameter 1: 24.00 %

History data 9: parameter 2: 24.00 %

History data 9: parameter 3: 24.00 %

History data 9: parameter 4: 24.00 %

History data 9: parameter 5: 24.00 %

History data 9: parameter 6: 24.00 %

History data 9: parameter 7: 24.00 %

History data 10: parameter 8: 24.00 %

History data 10: parameter 9: 24.00 %

History data 10: parameter 10: 24.00 %

History data 10: parameter 1: 24.00 %

History data 10: parameter 2: 24.00 %

History data 10: parameter 3: 24.00 %

History data 10: parameter 4: 24.00 %

History data 10: parameter 5: 24.00 %

History data 10: parameter 6: 24.00 %

History data 10: parameter 7: 24.00 %

History data 11: parameter 8: 24.00 %

History data 11: parameter 9: 24.00 %

History data 11: parameter 10: 24.00 %

History data 11: parameter 1: 24.00 %

History data 11: parameter 2: 24.00 %

History data 11: parameter 3: 24.00 %

History data 11: parameter 4: 24.00 %

History data 11: parameter 5: 24.00 %

History data 11: parameter 6: 24.00 %

History data 11: parameter 7: 24.00 %

History data 12: parameter 8: 24.00 %

History data 12: parameter 9: 24.00 %

History data 12: parameter 10: 24.00 %

History data 12: parameter 1: 24.00 %

History data 12: parameter 2: 24.00 %

History data 12: parameter 3: 24.00 %

History data 12: parameter 4: 24.00 %

History data 12: parameter 5: 24.00 %

History data 12: parameter 6: 24.00 %

History data 12: parameter 7: 24.00 %

History data 13: parameter 8: 24.00 %

History data 13: parameter 9: 24.00 %

History data 13: parameter 10: 24.00 %

History data 13: parameter 1: 24.00 %

History data 13: parameter 2: 24.00 %

History data 13: parameter 3: 24.00 %

History data 13: parameter 4: 24.00 %

History data 13: parameter 5: 24.00 %

History data 13: parameter 6: 24.00 %

History data 13: parameter 7: 24.00 %

History data 14: parameter 8: 24.00 %

History data 14: parameter 9: 24.00 %

History data 14: parameter 10: 24.00 %

History data 14: parameter 1: 24.00 %

History data 14: parameter 2: 24.00 %

History data 14: parameter 3: 24.00 %

History data 14: parameter 4: 24.00 %

History data 14: parameter 5: 24.00 %

History data 14: parameter 6: 24.00 %

History data 14: parameter 7: 24.00 %

History data 15: parameter 8: 24.00 %

History data 15: parameter 9: 24.00 %

History data 15: parameter 10: 24.00 %

History data 15: parameter 1: 24.00 %

History data 15: parameter 2: 24.00 %

History data 15: parameter 3: 24.00 %

History data 15: parameter 4: 24.00 %

History data 15: parameter 5: 24.00 %

History data 15: parameter 6: 24.00 %

History data 15: parameter 7: 24.00 %

History data 16: parameter 8: 24.00 %

History data 16: parameter 9: 24.00 %

History data 16: parameter 10: 24.00 %

History data 16: parameter 1: 24.00 %

History data 16: parameter 2: 24.00 %

History data 16: parameter 3: 24.00 %

History data 16: parameter 4: 24.00 %

History data 16: parameter 5: 24.00 %

History data 16: parameter 6: 24.00 %

History data 16: parameter 7: 24.00 %

Operation mode request:

Operation mode: --

Internal measured value MOSFET: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Internal measured value MON2: --

Internal measured value MON3: 808464432.0

Internal measured value DC voltage implausible monitoring unit: 808464432.0

Internal measured value MON3 MPU: --

Internal measured value MON3 ECC: --

Coolant recirculation pump: operating mode:

Coolant recirculation pump: target speed: 19.20 %

Coolant recirculation pump: actuator test:

Currents: current terminal 40: 18250.00 A

Currents: upper limit: 72.00 A

Currents: lower limit: -72.00 A

Currents: buzzer current: -79 A

Currents: phase 1: 18937.60 A

Currents: phase 2: 18937.60 A

Currents: phase 3: 18937.60 A

Voltages: terminal 30:

Voltages: voltage terminal 87: 4.80 V

Voltages: internal voltage supply 15V: 4.80 V

Voltages: voltage terminal 40: 24.00 V

Voltages: upper limit: 24.00 V

Voltages: lower limit: 24.00 V

Voltages: battery voltage terminal 40: 3084.00 V

Torques: starter generator torque: -40.00 N·m

Torques: upper limit: 12.00 N·m

Torques: lower limit: -12.00 N·m

Torques: torque specification: -40.00 N·m

Torques: torque equivalent of the consumer power: 12.00 N·m

Starter generator speed: -3832.00 1/min

Engine speed gradient: 3084.00 1/min/s

Motordrehzahl: 3084.00 1/min

Power output: electrical power: 473440 W

Power output: mechanical power: 473440 W

Stator temperature: 7.60 °C

Temperature of processor circuit board: 7.60 °C

Coolant temperature 1: 7.60 °C

Coolant temperature 2: 7.60 °C

Temperature of speed sensor:

Stellgliedtest

Controls

Coolant recirculation pump

Dienst­programme

Controls

Production mode

Deactivate production mode

Konfiguration

Controls

Konfiguration

Handbetrieb

Controls

SFD

Konfiguration