Car, AUDI, A4 2001-, 2005 (5), Avant, BPW 2,0l TDI , 103kW, 08 - Air conditioner (08 KLH)
Climate control - 08 - Air conditioner (08 KLH) - 0
Identification
Identifier: 4B0820043AM
System: A6-Klimavollautomat 0105
Software coding: 0
Workshop code: 2325
DTC
01810 (1810): Right temperature flap motor (V159)
01842 (1842): Potentiometer/Actuator for temperature flap, right (G221)
00532 (0532): Supply voltage
01273 (1273): Fresh air blower (V2)
Controls
Clear DTC
Data stream
A/C compressor regulating valve: -?-
A/C compressor regulating valve duty cycle: -?-
A/C high pressure sensor signal: -?-
Refrigerant circuit pressure: -?-
Current A/C disengagement: None A
A/C disengagement 1st history: None %
A/C disengagement 2nd history: 24.5 %
A/C disengagement 3rd history: Fresh air blower speed buttons bar
Left flap positioning motor: 5
Target left flap positioning motor: 12
Left flap positioning motor heating stop: 11
Left flap positioning motor cooling stop: 12
Right flap positioning motor: 230
Target right flap positioning motor: 234
Right flap positioning motor heating stop: 31
Right flap positioning motor cooling stop: 230
Defroster flap: 228
Target value of defroster flap: 231
Defrost flap lower stop: 32
Defrost flap upper stop: 227
Central air flap: 112
Target value of central air flap: 112
Central air flap lower stop: 28
Central air flap upper stop: 225
Air recirculation flap motor: 232
Target value of air recirculation flap motor: 233
Air recirculation flap motor lower stop: 22
Air recirculation flap motor upper stop: 229
Air flow flap: 226
Target value of air flow flap: 229
Air flow flap lower stop: 24
Air flow flap upper stop: 225
Footwell air outlet temperature: 231
Left outlet temperature: 20
Right outlet temperature: 228
Evaporator temperature sensor: 27.0 °C
Intake air temperature sensor: Not installed
Ambient temperature sensor: 27.0 °C
Calculated ambient temperature: 27.0 °C
A/C dash panel temperature sensor: 24.5 °C
Temperature sensor blower speed: 27.0 °C
Coolant temperature from dash panel: 26.0 °C
Idle speed up due to A/C on: 26.0 °C
Engine speed: 27.0 °C
Vehicle speed sensor: 2760 rpm
A/C compressor torque: Actual value °C
A/C compressor torque: Off
Fresh air blower: 0 rpm
Target voltage of fresh air blower: 0 km/h
Terminal 58d dimming: xxxxxxx0
Terminal 58s dimming: 0.0 N·m
Radiator fan: 2.1 V
Target value of radiator fan: 2.2 V
Radiator fan speed: Off %
Request for recirculated air mode: None requested %
Air quality sensor: Signal missing %
Rear window heater: 0
Front window heater: Activation / Heating
Additional heater: -?-
Additional heater shut-off: -?-
Left sun sensor light intensity: R. wind. off
Right sun sensor light intensity: Not installed
Front washer pump switch: Off
Front wiper switch: 1
Terminal 75: 0
Terminal 15: 1
Standing time: Off
Ignition key: Off
Auxiliary heater: 12.4 V
Side lights switch: 12.3 V
Protocol data level: 00:00
Base settings
Controls
Flap motor adaptation
Configuration
Controls
Configuration
Actuators test
Controls
Actuators test
Manual mode
Controls
Data stream
Basic setting
Adaptation
Login
Configuration