Bil, AUDI, A6 2018-, 2021 (M), Allroad, DKWC 2.0l TFSI , 140kW, 2B - Steering Column Locking (2B LSV)

Styretøj - 2B - Steering Column Locking (2B LSV) - 0

Identifikation

ASAM/ODX file identifikation: EV_ELVMarquMPVW36X

ASAM/ODX file version: A01001

Dele nummer: xxxxxxxxx

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

Stel nr.: xxxxxxxxxxxxxxxxx

Softwareversion: xxxx

Hardware vare nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardwareversion: xxx

Programmerbarhed: Programmerbare

Program consistency: Program present

System abbreviation: xxxx

Motor: CJTA

Advanceret identifikation

ASAM/ODX file identifikation: EV_ELVMarquMPVW36X

ASAM/ODX file version: A01001

Softwareversion: xxxx

Motor: CJTA

Programmability status: error in flash memory: Nej

Programmability status: flash memory faulty: Nej

Programmability status: communication error: Nej

Programmability status: flash memory not programmable: Nej

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Gyldig

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Gyldig

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Gyldig

Udstyrs nummer: 0

Importør nummer: 0

Værksteds kode: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostisk tilstand: VW diagnose

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware vare nummer: xxxxxxxxx

Hardwareversion: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Dele nummer: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmerbare

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Levende Data

Actuator test: Ikke aktiv

Security access: number of invalid keys, counter: 0

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: central electrics 2: Ikke aktiv

Communication status of data bus 1: central module comfort system: Aktiv

Communication status of data bus 1: access and start authorization: Aktiv

Communication status of data bus 1: central electrics 2: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Communication status of data bus 1: engine ECU 1: Ikke aktiv

Communication status of data bus 1: gateway: Ikke aktiv

Timeout recognition: gateway: 48

Timeout recognition: gateway: 48

Timeout recognition: gateway: 48

Timeout recognition: engine control module 1: 48

Timeout recognition: gateway: 48

Timeout recognition: gateway: 48

Timeout recognition: gateway: 48

Timeout recognition: gateway: 48

Timeout recognition: central electrics 2: 48

Timeout recognition: central module comfort system: 48

Timeout recognition: access and start authorization: 48

Timeout recognition: central electrics 2: 48

Timeout CAN messages: time to timeout mGW_Bremse_Getriebe: -- ms

Timeout CAN messages: time to timeout mGW_Motor: -- ms

Timeout CAN messages: time to timeout mKessy_4: -- ms

Timeout CAN messages: time to timeout mKombi_K1: -- ms

Timeout CAN messages: time to timeout mBremse_10: -- ms

Timeout CAN messages: time to timeout mMotor_10: -- ms

Timeout CAN messages: time to timeout mGW_Kombi: -- ms

Timeout CAN messages: CAN state: Aktiveret

Timeout CAN messages: time to timeout mBSG_3: -- ms

Timeout CAN messages: time to timeout mBSG_Kombi: -- ms

Timeout CAN messages: time to timeout mZKE_4: -- ms

Can msg mBSG_3-Can state: Ikke aktiveret

Can msg mBSG_3-Timeout: 246720 ms

Can msg mBSG_3-BS3_Klemme_S: Sluk

Can msg mBSG_3-BS3_Klemme_15: Sluk

Can msg mBSG_3-BS3_Klemme_50:

Can msg mBSG_3-BS3_Starterlaubnis: Sluk

Can msg mBSG_Combi-Can state: Ikke aktiveret

Can msg mBSG_Combi-Timeout: 246720 ms

Can msg mBSG_Combi-BSK_FT_geoeffnet: Sluk

Can msg mZKE_4-Can state: Ikke aktiveret

Can msg mZKE_4-Timeout: 246720 ms

Can msg mZKE_4-ZK4_verriegelt_ext: Sluk

Can msg mZKE_4-ZK4_gesafet_ext: Sluk

Can msg mGW_brake_transmission-Can state: Ikke aktiveret

Can msg mGW_brake_transmission-Timeout: 246720 ms

Can msg mGW_brake_transmission-GWB_Alt_FzgGeschw: Sluk

Can msg mGW_brake_transmission-GWB_FzgGeschw: 123.36 km/h

Can msg mGW_Engine-Can state: Ikke aktiveret

Can msg mGW_Engine-Timeout: 246720 ms

Can msg mGW_Engine-GWM_Alt_1_Motor: Sluk

Can msg mGW_Engine-GWM_Alt_2_Motor: Sluk

Can msg mGW_Engine-GWM_Alt_5_Motor:

Can msg mGW_Engine-GWM_Bremlicht_Schalter: Sluk

Can msg mGW_Engine-GWM_Bremtest_Schalter: Sluk

Can msg mGW_Engine-GWM_Interlock: Sluk

Can msg mGW_Engine-GWM_TypStartSteu:

Can msg mGW_Engine-GWM_Anl_Ausspuren: Sluk

Can msg mGW_Engine-GWM_Vorgluehen: Sluk

Can msg mGW_Engine-GWM_Motordrehzahl: 3084.00 1/min

Can msg mKessy_4-Can state: Ikke aktiveret

Can msg mKessy_4-Timeout: 246720 ms

Can msg mKessy_4-KY4_ID_Geber_1_im_Fzg: Sluk

Can msg mKessy_4-KY4_ID_Geber_2_im_Fzg: Sluk

Can msg mKessy_4-KY4_ID_Geber_3_im_Fzg:

Can msg mKessy_4-KY4_ID_Geber_4_im_Fzg: Sluk

Can msg mKessy_4-KY4_Startknopf_Bel: Sluk

Can msg mKessy_4-KY4_ID_Geber_Suche: Sluk

Can msg mCombi_K1-Can state: Ikke aktiv

Can msg mCombi_K1-Timeout: 246720 ms

Can msg mCombi_K1-K01_WFS_Schluessel: 48

Can msg mBrake_10-B10_QB_Wegimp_VL: Sluk

Can msg mBrake_10-B10_QB_Wegimp_VR: Sluk

Can msg mBrake_10-B10_QB_Wegimp_HL:

Can msg mBrake_10-B10_QB_Wegimp_HR: Sluk

Can msg mBrake_10-B10_Wegimp_VL: 12336

Can msg mBrake_10-B10_Wegimp_VR: 12336

Can msg mBrake_10-B10_Wegimp_HL: 12336

Can msg mBrake_10-B10_Wegimp_HR: 12336

Can msg mBrake_10-Can state: Ikke aktiveret

Can msg mBrake_10-Timeout: 246720 ms

Can msg mBrake_10-B10_Checksumme: 12336

Can msg mBrake_10-B10_Zaehler: 12336

Terminal 30 : 0.000 V

Endposition button blocked contact: button blocked contact 1: Ikke aktiveret

Endposition button blocked contact: button blocked contact 2: Ikke aktiveret

Endposition button unlocked contact: button unlocked contact 1: Ikke aktiveret

Endposition button unlocked contact: button unlocked contact 2: betjenes

Reset counter: resetcounter HaCo: 0

Error counter: shortcut motor driver lowside: --

Error counter: endposition switches implausible: --

Error counter: particle: --

Error counter: SBC-Error: --

Error counter: AD-converter corrupt: --

Error counter: HaCo CoCo communication disturbed: --

Error counter: enable CoCo incorrect active KL15: --

Error counter: enable CoCo incorrect active locking: --

Error counter: no CoCo enable KL15: --

Error counter: no CoCo enable locking: --

Error counter: reset HaCo CoCo failed: --

Error counter: reset SBC HaCo failed: --

Error counter: CPU-Test HaCo: --

Error counter: program sequence HaCo: --

Error counter: CPU-Test CoCo: --

Error counter: program sequence CoCo: --

Error counter: KL15 ELV locked: --

Error counter: SDA-Error: --

Error counter: return adress: --

Error counter: HaCo RAM-Check: 0

Error counter: HaCo ROM-Check: --

Error counter: HaCo EEPROM-Check: --

Error counter: CoCo RAM-Check: --

Error counter: CoCo ROM-Check: --

Error counter: endposition locked not reached: --

Error counter: shortcut motor driver highside: --

Activated fault reactions: locking disabled / clamp change up disabled: Nej

Activated fault reactions: KL50 disabled: Nej

Activated fault reactions: CoCo permanent reset: Nej

CPU request: diagnostic connection: Ikke aktiv

CPU request: key position copy: Ikke aktiv

CPU request: verfahren: Aktiv

CPU request: immobilizer authentication: Aktiv

CAN request: diagnoseverbindung: Ikke aktiv

CAN request: key position simulation: Ikke aktiv

CAN request: verfahren: Ikke aktiv

CAN request: wegfahrsperre authentifizierung: Ikke aktiv

Last reset reason: external: KL30

Last reset reason: internal: --

Can msg mMotor_10-Can state: Ikke aktiveret

Can msg mMotor_10-Timeout: -- ms

Can msg mMotor_10-M10_MotorStopp: --

Can msg mGW_ANT_1-Can state: Ikke aktiveret

Can msg mGW_ANT_1-Timeout: -- ms

Can msg mGW_ANT_1-GWA_Alt_3_Motor: --

Can msg mGW_ANT_1-MO3_Vorgluehen: --

Terminal S, line status: steering column lock target value: Sluk

Terminal S, line status: steering column lock: Sluk

Terminal S, line status: electronic central electric: Sluk

Terminal 15, line status: steering column lock target value: Sluk

Terminal 15, line status: steering column lock: Sluk

Terminal 15, line status: electronic central electric: Sluk

Terminal 50, line status: steering column lock target value: Sluk

Terminal 50, line status: steering column lock: Sluk

Terminal 50, line status: electronic central electric: Sluk

Starter button: switch contact 1: Ikke aktiveret

Starter button: switch contact 2: Ikke aktiveret

End switch for steering column, unlocked: Åbent kredsløb

End switch for steering column, locked: Åbent kredsløb

Unlocking motor: Ikke aktiveret

Locking motor: Ikke aktiveret

Steering column twisting: Not twisted

Play protection: Ikke aktiveret

Park selector lever position: Not engaged and not locked

Drive train uncoupling: powertrain (electronic central electrical system): Not decoupled

Drive train uncoupling: powertrain (engine): Not decoupled

Brake light switch: Sluk

Brake test switch: Sluk

Brake signal:

Motor Hastighed: 3084.00 1/min

Signal for motoromdrejningstal: Gyldig

ID sensor authenticated in vehicle: ID sensor 1: Nej

ID sensor authenticated in vehicle: ID sensor 2: Nej

ID sensor authenticated in vehicle: ID sensor 3:

ID sensor authenticated in vehicle: ID sensor 4: Nej

ID sensor search: Ikke aktiv

Rotary latch: Lukket

External vehicle locking: specified condition of lock per remote/key: Ulåst

External vehicle locking: specified condition of fuse per remote/key: Vehicle not secured

Køretøjs hastighed : 123.36 km/h

Vehicle speed signal: Gyldig

Distance impulses: signal state: Gyldig

Distance impulses: signal state: Gyldig

Distance impulses: signal state:

Distance impulses: signal state: Gyldig

Distance impulses wheel 1: 12336

Distance impulses wheel 2: 12336

Distance impulses wheel 3: 12336

Distance impulses wheel 4: 12336

Steering column lock current condition/learn mode: current condition: Condition as delivered

Steering column lock current condition/learn mode: learn mode: Adapted

Ignition starter activation: activation: Manuelt

Ignition starter activation: signal state: Gyldig

Disengage starter: disengage request: Nej

Disengage starter: signal state: Gyldig

Terminal 15 redundancy, line status: steering column lock target value: Sluk

Terminal 15 redundancy, line status: steering column lock: Sluk

Terminal 15 redundancy, line status: electronic central electric: Sluk

Terminal 50R (read-out signal) wire status: Sluk

Start concept adapted:

Diagnostisk tilstand: VW diagnostic mode

Udgangs test

Controls

Simulation of starter button

Muligheder

Controls

Immobilizer - login

Immobilizer - download WFS 4

Subbus-slave, FAZIT identification string

Activating and deactivating all development messages

Konfiguration

Controls

Konfiguration

Manual mode

Controls

SFD

Konfiguration