Bil, AUDI, A6 1998-, 2000 (Y), Saloon, APU 1,8l Turbo Motronic , 110kW, 35 - Central locking (35 ZEN)

Body kontrol modul - 35 - Central locking (35 ZEN) - 0

Identifikation

Identificere : 4B0962258J

System: Central Lock/Alarm D33

Software coding: 16232

Værksteds kode: 2325

Fejlkoder

01560 (1560): Passenger door

Controls

Clear DTC

Levende Data

Driver door key switch: Not operated

Interior central locking switch: Not operated

Feedback signal for driver door lock: Ulåst

Feedback signal for driver door lock: Not safe

Passenger door key switch: Not operated

Feedback signal for passenger door lock: Ulåst

Feedback signal for passenger door lock: Not safe

Feedback signal for rear right door lock: Ulåst

Feedback signal for rear right door lock: Not safe

Feedback signal for rear left door lock: Ulåst

Feedback signal for rear left door lock: Not safe

Driver door contact switch: Dør åben

Passenger door contact switch: Dør lukket

Right rear door contact switch: Dør lukket

Left rear door contact switch: Dør lukket

Rear lid key switch: Not operated

Rear lid contact switch: Flap closed

Rear lid remote unlock button: Not operated

Rear lid soft-touch: Not operated

Interior light: Tænd

Shut-off delay terminal 15: Relay off

Comfort function: Not operated

Luggage compartment illumination: Sluk

Position of matched key: 0.0

Remote command: xx0000xx

Matched keys in position: xx1110xx

Vehicle speed sensor signal: 0 km/h

Startspærre: Sluk

Remote control "Open" confirmation (2x blink): Ikke aktiv

Remote control: Ikke aktiv

Sirene alarm type: Andet

Remote control "Close" confirmation (1x Blink): Ikke aktiv

Anti-theft confirmation via horn: Ikke aktiv

Door/window regulator logic: Ikke aktiv

Rear lid release locking via speed: Ikke aktiv

Central lock locking via speed: Ikke aktiv

Comfort function window lifters/sunroof via remote control: Ikke aktiv

Steering wheel location: Left-hand drive

Rear lid unlocking: Ikke aktiv

Anti-theft confirmation via blink: Ikke aktiv

Selective locking: Ikke aktiv

Anti-theft system: Ikke tilstede

Konfiguration

Controls

Konfiguration

Muligheder

Controls

Remote control adaptation

Udgangs test

Controls

Udgangs test

Manual mode

Controls

Levende Data

Basic setting

Adaptation

Login

Konfiguration