Bil, AUDI, A3 2020-, 2022 (N), Sportback, CZPB 2.0l TDI , 140kW, 6D - Rear lid electronics (6D HDE)
Dør moduler - 6D - Rear lid electronics (6D HDE) - 0
Identifikation
ASAM/ODX file identifikation: EV_HDSGAU316
ASAM/ODX file version: 001001
Dele nummer: xxxxxxxxx
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
Stel nr.: xxxxxxxxxxxxxxxxx
Softwareversion: xxxx
Hardware vare nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardwareversion: xxx
Programmerbarhed: Programmerbare
Program consistency: Program present
System abbreviation: xxxx
Motor: CJTA
Advanceret identifikation
ASAM/ODX file identifikation: EV_HDSGAU316
ASAM/ODX file version: 001001
Softwareversion: xxxx
Motor: CJTA
Programmability status: error in flash memory: Nej
Programmability status: flash memory faulty: Nej
Programmability status: communication error: Nej
Programmability status: flash memory not programmable: Nej
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Gyldig
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Gyldig
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Gyldig
Udstyrs nummer: 0
Importør nummer: 0
Værksteds kode: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnostisk tilstand: VW diagnose
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware vare nummer: xxxxxxxxx
Hardwareversion: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Dele nummer: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmerbare
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Read DTC (Normal mode)
Controls
Clear DTC
Read DTC (Agressive mode)
Controls
Clear DTC
Levende Data
Actuator test: Ikke aktiv
Terminal 30 : 240.55 V
ECU temperature: 12336 °C
Engine start using start-stop function: Ikke aktiv
Transport mode: Ikke aktiv
Kilometer tæller: 3158064 km
Ambient temperature: -26 °C
Supply voltage terminal 30 for actuators: 240.55 V
Pressing a button: button for rear lid unlocking in rear lid: Ikke aktiveret
Pressing a button: button for closing in the rear lid: Ikke aktiveret
Pressing a button: rear lid remote release button: Ikke aktiveret
Pressing a button: rear lid unlock button in remote key: Ikke aktiveret
Pressing a button: button for closing and locking in the rear lid: betjenes
Motor 1 for tailgate:
Motor 1 for rear lid, activation: 48 %
Motor 1 for tailgate, current: 240.55 A
Motor 2 for tailgate:
Motor 2 for rear lid, activation: 48 %
Motor 2 for tailgate, current: 240.55 A
Rear lid position, relative: 48 %
Rear lid position, absolute: 12336
Position programmable opening stop: 48 %
Learned open end position: 12336
Stigningsvinkel: 48 °
Krængningsvinkel: 48 °
Play protection time-out time: 48 sek
Remaining run time for play protection: 48 sek
Activations of rear lid closing button: 12336
Activations of rear lid unlocking button: 12336
Activations of rear lid remote unlocking switch: 12336
Activation of remote key button rid lid opening: 12336
Opening cycle counter: 12336
Closing cycle counter: 12336
Counter obstruction detected: 12336
Counter of selectable opening stop adapted: 12336
Play protection counter active: 12336
Counter for function limitation due to insufficient voltage: 12336
Counter for function limitation due to excessive voltage: 12336
Counter for lock or closing assist implausible: 12336
Counter for function limitation due to excessive temperature: 12336
Counter for terminal 30 reset: 12336
Tailgate condition:
Status of rear lid lock: terminal 1: Åben
Status of rear lid lock: terminal 2: Åben
Status of closing assist: Retracted
Status of pinch protection: clamping strip 1: No obstacle
Status of pinch protection: clamping strip 2:
Status of pinch protection: clamping strip 3: No obstacle
Status of pinch protection: clamping strip 4:
Warning tone:
Position sensor 1: 12336
Position sensor 2: 12336
Status sensor 1:
Status sensor 2:
Motor 1 for rear lid, voltage: 240.55 V
Motor 2 for rear lid, voltage: 240.55 V
Terminals for closing assist: closing assistance: Not locked
Terminals for closing assist: terminal 1: Åben
Terminals for closing assist: terminal 2: Ikke tilstede
Counter of flap opening angle basic settings: 12336
Static current shutdown level:
Trailer detected: Not recognized
Time stamp: year: 12
Time stamp: month: 0
Time stamp: hours: 3
Time stamp: day: 24
Time stamp: minutes: 0
Time stamp: seconds: 48
Status of basic setting data: Basic setting performed successfully
Hall sensors for position detection: motor in rear lid control module, sensor 1: betjenes
Hall sensors for position detection: motor in rear lid control module, sensor 2: betjenes
Hall sensors for position detection: motor 2 in rear lid, sensor 1: betjenes
Hall sensors for position detection: motor 2 in rear lid, sensor 2: betjenes
Pinch protection voltages: clamping strip 1: 192.75 V
Pinch protection voltages: clamping strip 2: 192.75 V
Pinch protection voltages: clamping strip 3: 192.75 V
Pinch protection voltages: clamping strip 4: 192.75 V
Counter for emerg. run. ops. because closing pos. not reached: 12336
Counter for closing operations canceled by lock-up: 12336
Warning tone, output voltage: 60.24 V
Pitch angle incline sensor, voltage: 240.55 V
Roll angle incline sensor, voltage: 240.55 V
Motor 1 for rear lid, RPM: 12336 1/min
Motor 2 for rear lid, RPM: 12336 1/min
Number of activations to play protection active: 48
Reason for cancellation of rear lid procedure: Nøgle
Diagnostisk tilstand: VW diagnostic mode
Number of possible access authorizations: --
Consistency of EEPROM data: --
Køretøjs hastighed : -- km/h
Udgangs test
Controls
Open rear lid
Close rear lid
Open rear lid incrementally
Close rear lid incrementally
Warning tone
Activate closing assistance
Basic setting
Controls
Adapt flap opening angle
Adapt zero position for vehicle inclination
Muligheder
Controls
Status of adaptation
Deactivate production mode
Production mode
Comfort closing
Comfort opening
Opening with trailer detected
Reversing when opening
Reverse path when opening
Reversing when closing
Reverse path when closing
Stop rear lid movement when changing terminal
Activation using rear lid remote unlocking switch
Activation using rear lid opening button in remote key
Rear lid closing button, debounce time
Rear lid central locking button, debounce time
Rear lid closing button, start activation
Rear lid central locking button, start activation
Speed threshold for "vehicle is moving"
Characteristics in production mode
Increment for actuator test open rear lid
Increment for actuator test close rear lid
Reset all counters
Time window for opening further than programmed opening stop
Program opening stop
Pitch of acoustic warning
Volume of acoustic warning
Duration of warning signal in automatic operation
Duration of warning signal in blocking detection
Length of acknowledgement signal when programming opening stop
Duration of warn. signal during activation upon cancel function
Upper end stop, maximum value
Upper end stop, minimum value
Detection area lower
Detection area upper
Start-stop characteristics
Delay restarting after start-stop
Offset for maximum programmable opening stop
Tolerance range for soft stop
Close rear lid
Setting the error "Button for closing rear lid, open circuit"
Start of automatic run with manual opening
Start of automatic run with manual closing
Delete programmed opening stop
Delay for rear lid closure
Delay for rear lid opening
Warning signal when closing with button
Warning signal when opening with button
Time for closing rear lid with remote control
Warning tone when key is in luggage compartment
Rear lid position for extending closing aid
Behavior when key is in luggage compartment during closing
Behavior when key is in luggage compartment after closing
Monitoring of key in luggage compartment
Close using remote control, end when leaving the immediate area
Locking range offset upper stop
Konfiguration
Controls
Konfiguration
Manual mode
Controls
SFD
Konfiguration