RHH - DCM3.5 BR2 - 0
Identifikation
PSA reference: 96 66 91 25 80
ECU manufacturer: VDO
Additional number: 96 66 91 25 80
Softwareversion: 05 00
Software reference: 79 05 58
Fejlkoder
P0487: Exhaust gas recirculation (EGR) valve stuck open
P1499: Air metering valve position incorrect (too open), After Sales
Controls
Clear DTC
Levende Data
Condition of neutral sensor: FALSK
Clutch pedal: 220 %
Status limit vehicle speed: Aktiveret
EGR valve high limit initial programming: 88 %
Last initialised position of EGR valve lower limit: 17 %
EGR valve high limit last programming: 2 %
EGR valve low limit last programming: 14 %
Initialised initial position of the air mixer upper limit: 96 %
Initialised initial position of the air mixer lower limit: 14 %
Locking of the ECU: Låst
Last initialised position of the air mixer upper limit: 94 %
Last initialised position of the air mixer lower limit: 10 %
Initialised initial position of the turbo upper limit: 69 %
Initialised initial position of the turbo lower limit: 3 %
Last initialised position of turbo upper limit: 10 %
Last initialised position of turbo lower limit: 10 %
Statspærrestatus: After-sales status
Problem detected when transmitting the unlock code: The programming status of the engine immobiliser cannot be read
Motor status: Self-powered starting
Camshaft and crankshaft synchronization: Nej
Mixer programming status: Not carried out
EGR valve learning status: Done
Turbo learning: Not carried out
First initialisation of the air mixer: Done
Status of first learning of EGR valve: Not carried out
First initialisation of the turbo: Done
Fuel flow regulator: 0 %
Target fuel pressure: 0 bar
Fuel pressure measured: 0 bar
Injected flow measured: 0.0 mg/impulse
Motor Hastighed: 0 Omdr.
Brændstoftemperaturføler: -50 °C
Injector opening correction strategies activation status: Inaktiv
Injection time cylinder 1: 0.0 ms
Injection time cylinder 3: 0.0 ms
Injection time cylinder 4: 0.0 ms
Køretøjets hastighed sensor: 0 km/h
Injection time cylinder 2: 0.0 ms
Fuel flow regulator: 0.0 mA
Gaspedalposition: 0 %
Measured turbo pressure: 465 mbar
Barometrisk tryk føler: 52 mbar
Turbo position setting: 18 %
Turbo position repeat: 25 %
Mixer position reference value: 10 %
Mixer position repeat: 26 %
Air flow sensor air temperature: 195 °C
Inlet air temperature at manifold: -7 °C
Turbocharging pressure reference value: 175 mbar
Gear transmission ratio: 1
Gearbox type: Manuelt
Cruise control speed setting: 1 km/h
Speed limiter speed setting: 1 km/h
Generator progressive charge reference: 1 %
Batteri spænding: 0.10 V
Supply voltage 5V N1: 257 mV
Clutch pedal: Nedtrykket
Status for fartpilotsystem: Inaktiv
Principal brake pedal: Udløst
Hastighedsbegrænser: Inaktiv
Brake pedal redundant: Udløst
Accelerator pedal point of resistance sensor: Not exceeded
Speeder pedal positions føler N1: 257 mV
Speeder pedal position N2: 257 mV
A/C circuit pressure: 1.0 bar
Oil pressure: OK
Oil level: 24 mV
Motor kølevæske temperatur føler: -40 °C
Cooling fan reference speed: 27 %
Køleventilatorhastighed: 12 %
Fan speed 2 setting:
Cylinder 1 injector code: SP9A547HT2P9LPWMEK11
Cylinder 2 injector code: BP5A8T9462P9KRU52AWZ
Cylinder 3 injector code: B77A4TRHJES9KRUM6F10
Cylinder 4 injector code: HP5A8T93A2P8L8U4T8X0
DPF information
Motor Hastighed: 0 Omdr.
Air flow sensor air temperature: 195 °C
Inlet air temperature at manifold: -7 °C
Mixture calculated by the O2 sensor: 0.010
Activation heating O2 sensor: 10 %
Diesel Particulate filter (DPF) soot mass: 35.3 g/l
Diesel Particulate filter (DPF) cinder count: 10 %
Diesel Particulate filter (DPF) distance before replacing: 46 km
Diesel Particulate filter (DPF) differential pressure: 65199 mbar
Additive tank: 10 ml
Volume of additive remaining in the reservoir: 23 ml
Quantity of additive deposited in the filter: 1 g
Diesel Particulate filter (DPF) temperature: 273 °C
Authorisation of regeneration: Nej
Additive minimum level: Not reached
Diesel Particulate filter (DPF) regeneration status: Inaktiv
Power consuming equipment activation request: Nej
Diesel Particulate filter (DPF) distance since last regeneration: 257 km
Average distance between the last 10 regenerations: 10 km
Short term regeneration capacity: 15 %
Long term regeneration capacity: 10 %
Batteri spænding: 0.10 V
Udgangs test
Controls
Cooling fan high speed
Cooling fan low speed
Indsprøjtnings dyse 1
Indsprøjtnings dyse 2
Indsprøjtnings dyse 3
Indsprøjtnings dyse 4
Fuel flow regulator
Pre-post heating relay control
Power supply relay
Turbocharger actuator
EGR exchanger bypass
Checking pressurisation of air entering the engine
Manifold inlet pressure sensor checking
Checking engine setting
Air flow circulation
EGR circuit checking
Checking the functioning of the air circuit assembly
EGR-ventil
O2 sensor heating
Heater matrix water pump: Activation
Additive pump
Exhaust heat recovery valve checking
Muligheder
Controls
DPF regeneration (vehicle stationary)
Filling of the additive reservoir or pouch
Replacement of the diesel additive reservoir, of the pump or of the pipes
DPF replacement
Differential pressure sensor replacement
EGR valve change
EGR exchanger replacement
Turbocharger replacement
Mass air flow sensor replacement
High Pressure pump replacement
Flow regulation valve replacement
Fuel rail pressure sensor replacement
O2 sensor replacement
Change of engine ECU without the MAF
Change of engine ECU with the MAF
Ancillary drive belt replacement
Exhaust manifold replacement
Cylinder head replacement
Initialization
Injectors replacement