Bil, PEUGEOT, 407, 9HZ - EDC16C3 CAN

9HZ - EDC16C3 CAN - 0

Identifikation

PSA reference: 96 53 95 89 80

ECU manufacturer: Bosch

Additional number: 96 64 61 80 80

Softwareversion: 03 01

Software reference: 63 26 87

Fejlkoder

P2127: Air heater throttle position copy signal - circuit short to ground or value too low

Controls

Clear DTC

DPF information

Additive adding system fault: Addition of additive not possible

Catalytic converter downstream temperature: 105.9 °C

Exhaust gas differential pressure: 0.0 mbar

Intake air temperature sensor: 48 °C

Diesel Particulate filter (DPF) load state: 18.4 %

Average distance between the last 5 regenerations: 231.1 km

Diesel Particulate filter (DPF) distance since last regeneration: 410.9 km

Weight of additive in the PEF: 0.0 G

Volume of additive remaining in the reservoir: 200 ml

Levende Data

Additional heater: Inaktiv

Inlet air temperature at manifold: 47.7 °C

Indlæringstilstand: Last EGR valve programming correct; First EGR vlve programming correct; Last EGR butterfly programming correct; First EGR butterfly programming correct; Last air heating butterfly programming correct; First air heating butterfly programming correct; ;

Barometrisk tryk føler: 1.000 bar

Measured turbo pressure: 1.000 bar

Brake pedal switch 1: Udløst

Brake pedal switch 2: Udløst

A/C authorisation: Nej

A/C thermostat: Normal

Køretøjets hastighed sensor: 0 km/h

Clutch pedal: Udløst

Gear engaged: Frigear

Brændstoftemperaturføler: 38.7 °C

A/C pressure sensor: 7.2 bar

Konfiguration: Korrekt

Motor kølevæske temperatur føler: 62.6 °C

Additive adding system fault: Addition of additive not possible

Cooling fan relay: Inaktiv

Køleventilatorhastighed: 0.0 %

Cooling fan reference speed: 0.0 %

Batteri spænding: 12.45 V

EGR valve position repeat: 0.0 %

Camshaft and crankshaft synchronization: Nej

Fuel flow regulator: 14.5 %

Diesel output delivered by the pump reference value: 9694.1 mm³/s

Air flow volume: 0.0 kg/h

Motor status: Tænding til

EGR valve open cycle ratio: 0.0 %

Pre-post heating relay: Inaktiv

A/C cut-off request: Cut-off

Motor Hastighed: 0.0 Omdr.

Fuel pressure measured: 0.0 bar

Accelerator pedal position sensor: 0.0 %

Injected fuel quantity: 21.6 mg/impulse

Luft masse måler: 0.0 mg/impulse

Pre-injection advance 1: 0.7 °

Fuel injection advance (main): 0.7 °

Injector control error status: No fault

Turbocharging pressure reference value: 1.035 bar

Reference fuel pressure: 274.5 bar

Turbo pressure duty cycle: 68.2 %

Bypass throttle solenoid valve open cycle ratio: 0.0 %

EGR throttle electrovalve open cycle ratio: 0.0 %

Air flow reference for EGR: 638.6 mg/impulse

Bypass flap position repeat (if present): 1.2 %

EGR throttle position: 1.2 %

Immobilizer

Locking of the ECU: Ulåst

Statspærrestatus: Matched ECU

Problem detected when transmitting the unlock code: No problem

Udgangs test

Controls

Cooling fan high speed

Cooling fan low speed

Additional heating relay

EGR-ventil

EGR throttle

Turbocharger control solenoid valve

Fuel flow regulator

Pre-post heating relay control

Muligheder

Controls

Diesel particulate filter replacement

Diesel particulate filter static regeneration

Initialization of the additive level when filling or replacing the additive reservoir

Programming of the additive system if replacing parts (additive reservoir, pump or pipes)

EGR valve change

EGR exchanger replacement

Injectors replacement