PKW, PEUGEOT, 407, BVA AM6
Transaxle - BVA AM6 - 0
Identifikation
PSA reference: 96 59 83 86 80
Steuergerät-Hersteller: Siemens
Zusatznummer: 96 59 83 86 80
Diagnoseversion: 00
Calibration version: 25 05
Softwareversion: 25 05
Ausstoß: US 83/Euro 3 Mercosur, Brazil, China, without EOBD (all models expert Partner)
ECU production date: --
Software reference: 59 63 25
Fehlercode
U1208: Fault in the information transmitted by the engine ECU incorrect value received
Controls
Fehlercode löschen
Ist-Werte
Engine stalling not linked with converter lock-up: Ja
Engine stalling linked with converter lock-up: Ja
Number of stalling clearing cycles: 18 %
Gang gewählt: Intermediate P/R
Eingelegter Gang: 6
Drehmomentwandler : Converter in regulation or sliding
Sport-Taste: Freigegeben
Snow mode switch: Freigegeben
Geber für Gaspedalstellung: 17.5 %
Reduction of torque requested by the automatic gearbox: 64.0 N·m
Engine torque requested by the driver: 408.0 N·m
Torque reference value requested by the automatic gearbox: 378.1 N·m
ASR/ESP in regulation mode: Ja
Request for switching on of the emission control fault warning light (MIL lamp): Nein
Request for switching on of an automatic gearbox overheating warning light: Ja
Secondary brake switch: Geschlossen
Ölwechsel erforderlich: Ja
Main brake switch: Geschlossen
RCD reawakening: Main
Front wheels average speed: 0.0 UpM
Raddrehzahlsensor hinten rechts: 0.0 km/h
Raddrehzahlsensor hinten links: 223.8 km/h
Front wheels average speed: 0.0 km/h
Automatikgetriebe-Öltemperatur: 26 °C
Batteriespannung: 12.10 V
Außenlufttemperatur : 32.5 °C
Motordrehzahl: 4.5 UpM
Istwert Motordrehmoment: 48.0 N·m
Geber für Kühlmitteltemperatur: 42 °C
Control of the "S2" solenoid valve (Management of the engine break): Requested by inactive
Control of the "S1" solenoid valve (Management of the engine break): Nicht definiert
Control current SLU: 150 mA
Return current (measurement) SLU: 1920 mA
Electrical status of the solenoid valve SLU: Falsch
Control current SLT: 180 mA
Return current (measurement) SLT: 320 mA
Electrical status of the solenoid valve SLT: Controlled
Control current SLB1: 1820 mA
Return current (measurement) SLB1: 960 mA
Electrical status of the solenoid valve SLB1: Aktiviert
Control current SLC1: 100 mA
Return current (measurement) SLC1: 960 mA
Electrical status of the solenoid valve SLC1: Aktiviert
Control current SLC2: 1360 mA
Return current (measurement) SLC2: 1700 mA
Electrical status of the solenoid valve SLC2:
Control current SLC3: 940 mA
Return current (measurement) SLC3: 960 mA
Electrical status of the solenoid valve SLC3: Aktiviert
Getriebeeingangsdrehzahl: 192 UpM
A/T input speed calculated: 128 UpM
Getriebeausgangsdrehzahl: 0 UpM
A/T output speed (recommended): 0 UpM
Converter sliding speed: -1664.0 UpM
Converter sliding speed (theoretical value): 1152.0 UpM
Declutch when stationary: Nicht aktiv (Gang P oder N)
Intermittent switching to emergency (refuge) mode: Nein
Automatic gearbox in emergency mode (refuge): Ja
Operating pattern used by automatic gearbox: Minimum operation
Key locking control (key - lock): Verriegelt
Status RCD line: Aktiv
Gear decrease (-): Inaktiv
Geschwindigkeitsregelanlage: Activated or effective
Gear increase (+): Inaktiv
Starting inhibiting control ( start Lock ): Aktiviert
Oil counter read
Oil wear counter: 51200194
Stellgliedtest
Controls
Schaltmagnetventil "A"
Schaltmagnetventil "B"
Solenoid valve SLT
Magnetventil SLB1
Magnetventil SLC1
Magnetventil SLC2
Magnetventil SLC3
Solenoid valve SLU
Shift lock solenoid
Control of the starting prevention (Start Lock)
Key locking control (key Lock)
Dienstprogramme
Controls
Programming of neutral position
Replacement of the automatic gearbox oil