Bil, PEUGEOT, 4008, Climate control

Klima Anlæg - Climate control - 0

Identifikation

ECU origin: Not recognized

Hardware number: 00 01

ECU reference: 7820A337

Diagnose version: 01 54

Softwareversion: 37 31 4B

Softwareversion:

VIN no (original): VF3VV4HNH9U903189

Motor type: 4HN

Stel nr.: VF3VV4HNH9U903189

Fejlkoder

Controls

Clear DTC

Levende Data

Passenger compartment air temperature: 56.8 °C

Air thermo sensor: 0.0 °C

Driver photo sensor: 27.5 W/m2

Motor kølevæske temperatur føler: -13 °C

Outside air temperature: 0.0 °C

Motor Hastighed: 43 Omdr.

Køretøjets hastighed sensor: 8.6 km/h

Driver air mix flap potentiometer: 3411.8 %

Distribution motor position: 1474.0 %

Front blower fan: 209

Target front blower fan: 24

Air outlet c/o potentiometer (target): De-icing

In/out select damp poten (target): Recirkulation

A/C compressor relay: Tænd

A/C-kontakt: Tænd

Bagrudeafdugningskontakt: Tænd

Condenser fan: 221 %

PTC heater 1: Tænd

PTC heater 2: Tænd

PTC heater 3: Tænd

A/C setting temperature: -11.0 °C

A/C high pressure sensor: Høj

Low pressure: Faulty

Refrigerant leak: No leaks

Air outlet c/o set dial position: Fejl

A/C switch operation flag: Tænd

Fan-: Tænd

Fan+: Tænd

Rear defogger switch lamp: Sluk

Auto button telltale: Inaktiv

A/C request telltale: Sluk

Defogger telltale: Sluk

Air recirculation telltale: Sluk

A/C compressor drive flag: Tænd

Wiper operation flag: Inaktiv

Batteri spænding: 12.10 V

IOD fuse eqipment flag: Incorrect/absent

A/C panel type: Not specified

System operation time: 327675 sek

Compressor use times: 43818

Rear defogger use times: 164

PTC heater 1 use times: 4091

PTC heater 2 use times: 8756

PTC heater 3 use times: 3536

In/out air c/o poten drive time: 1863.3 sek

Air flow circulation: 239.7 sek

Air mix flap potentiometer drive time: 68043.7 sek

Hot state time (interior temperature): 223 min

Cold state time (interior temperature): 23041 min

Hot state time (ambient temperature): 43770 min

Cold state time (ambient temperature): 4405.0 min

Maximum ambient temperature: 134.1 °C

Minimum ambient temperature: 27.3 °C

Maximum engine coolant temperature: -37 °C

Engine high speed time: 1105 sek

Maximum engine speed: 64000 Omdr.

High pressure drive time: 250 min

High pressure cuf-off times: 153

Maximum pressure: 170 kPa

A/C use rate: 1275 sek

Compressor operation rate: 283995 sek

Eco operation rate: 83886075 sek

Recirculation use rate: 40 min

Face mode use rate: 61610 min

B/L mode use rate: 63353 min

Def mode use rate: 3546 min

Fan off use rate: 545015 sek

Fan 1-2 step use rate: 657500 sek

Fan 3-4 step use rate: 1505215 sek

Fan 5-6 step use rate: 809745 sek

Fan 7-8 step use rate: 73455 sek

Temp 1-7 step use rate: 20450 min

Temp 8-10 step use rate: 1730 min

Temp 11-13 step use rate: 870 min

Temp 17-19 step use rate: 23750 min

Temp 20-22 step use rate: 1365 min

Temp 23-29 step use rate: 1200 min

Blower dial operation times: 4109

Udgangs test

Controls

In/out select damper

Air mix flap motor

Front blower fan

Air outlet c/o damper

Condenser fan

A/C switch

Rear defroster

PTC heater