Car, OPEL, Insignia, 2016, Liftgate control module

Door modules - Liftgate control module - 0

Identification

Identifier: 00 00

System code: 00

Manufacturer enable counter (MEC): 0

ECU diagnostic address: --

Detected RPO: --

Detected component: --

Manufacturer`s traceability number: --

Software module 1 identifier: 12654173

Software module 2 identifier: 55577673

Software module 3 identifier: 55577209

End model part number: 55577619

Base model part number: 55574337

Software module 1 identifier alpha code: AA

Software module 2 identifier alpha code: AA

End model part number alpha code: 00

Base model part number alpha code: 00

DTC

Controls

Clear DTC

Data stream

Liftgate front control switch:

Liftgate latch pawl switch:

Power liftgate handle switch:

Liftgate latch ratchet switch:

Liftgate rear close switch:

Liftgate latch sector switch:

Liftgate supply voltage 1: V

Liftgate supply voltage 2: V

Liftgate secondary object detection: V

Liftgate mode switch: Counts

Liftgate mode switch:

Liftgate open/close position learned:

Last liftgate close malfunction data

Liftgate closing disabled - liftgate mode switch off: --

Liftgate closing disabled - transmission not in park: --

Liftgate closing disabled - engine cranking: --

Liftgate closing disabled - content theft deterrent armed: --

Liftgate closing disabled - supply voltage out of range: --

Liftgate closing disabled - vehicle speed above threshold: --

Liftgate closing disabled - dtc present: --

Liftgate closing disabled - latch malfunction detected: --

Liftgate closing disabled - function aborted by user: --

Liftgate closing disabled - object detected: --

Liftgate closing disabled - high current: --

Liftgate closing disabled - timeout: --

Liftgate closing disabled - no position sensor signal: --

Liftgate closing disabled - incorrect latch position: --

Liftgate closing disabled - liftgate handle switch pressed: --

Liftgate closing disabled - secondary object detection pressed: --

Liftgate closing disabled - air bag deployed: --

Liftgate closing disabled - temperature out of range: --

Liftgate closing disabled - lost can bus communication: --

Liftgate closing disabled - liftgate window ajar: --

Liftgate closing disabled - multiple activations: --

Liftgate angle: 0 °

Last liftgate open malfunction data

Liftgate opening disabled - liftgate mode switch off: Inactive

Liftgate opening disabled - transmission not in park: Inactive

Liftgate opening disabled - calibration: Inactive

Liftgate opening disabled - engine cranking: Inactive

Liftgate opening disabled - content theft deterrent armed: Inactive

Liftgate opening disabled - supply voltage out of range: Inactive

Liftgate opening disabled - vehicle speed above threshold: Inactive

Liftgate opening disabled - dtc present: Inactive

Liftgate opening disabled - latch malfunction detected: Inactive

Liftgate opening disabled - angle exceeds learned maximum: Inactive

Liftgate opening disabled - function aborted by user: Inactive

Liftgate opening disabled - object detected: Inactive

Liftgate opening disabled - high current: Inactive

Liftgate opening disabled - timeout: Inactive

Liftgate opening disabled - no position sensor signal: Inactive

Liftgate opening disabled - doors locked: --

Liftgate opening disabled - liftgate handle switch pressed: --

Liftgate opening disabled - air bag deployed: --

Liftgate opening disabled - temperature out of range: --

Liftgate opening disabled - lost can bus communication: --

Liftgate opening disabled - liftgate window ajar: --

Liftgate opening disabled - multiple activations: --

Liftgate angle: 0 °

Engineering data 1

Opening abort counter - Zone 0: Counts

Opening abort counter - Zone 1: Counts

Opening abort counter - Zone 2: Counts

Opening abort counter - Zone 3: Counts

Opening abort counter - Zone 4: Counts

Opening abort counter - Zone 5: Counts

Opening abort counter - Zone 6: Counts

Opening abort counter - Zone 7: Counts

Opening abort counter - Zone 8: Counts

Opening abort counter - Zone 9: Counts

Opening abort counter: Counts

Closing abort counter - zone 0: Counts

Closing abort counter - zone 1: Counts

Closing abort counter - zone 2: Counts

Closing abort counter - zone 3: Counts

Closing abort counter - zone 4: Counts

Closing abort counter - zone 5: Counts

Closing abort counter - zone 6: Counts

Closing abort counter - zone 7: Counts

Closing abort counter - zone 8: Counts

Closing abort counter - zone 9: Counts

Engineering data 2

Closing abort counter - secondary object Detection: Counts

Liftgate motor timeout counter: Counts

Prop rod failure counter: Counts

Liftgate inhibit counter - open/close position not learned: Counts

Control module processor reset counter: Counts

Actuators test

Controls

Liftgate open/close

Utility

Controls

Liftgate maximum open position learn