Car, OPEL, Astra J, 2017, Climate control
Climate control - Climate control - 0
Identification
Vehicle Identification Number (VIN): W0LGT8EBXA1007787
Subscriber ID: O100057235
Programming date: 8209
Identifier: 00 00
Previous subscriber ID: *10MDZ7
Manufacturer enable counter (MEC): 0
ECU - diagnostic address: --
Manufacturer's traceability number: --
Software module 1 identifier: 12654173
Software module 2 identifier: 55577673
Software module 3 - identifier: 55577209
End model part number: 55577619
Base model part number: 55574337
Software module 1 identifier alpha code: AA
Software module 2 identifier alpha code: AA
Software module 3 identifier alpha code: AA
End model part number alpha code: 00
Base model part number - alpha code: 00
GMLAN identification data - bus 1 type: High speed CAN-bus
GMLAN identification data - GMLAN kernel 1 version: 00 00
GMLAN identification data - data dictionary 1 version: --
Detected component: --
DTC
Controls
Clear DTC
Data stream
Rear defogger - activated by automatic: --
Rear defogger mode: --
HVAC afterblow configuration: --
Battery voltage: 3.0 V
Ambient air temperature (filtered): -40 °C
Mode door actuator - direction: Stop
Recirculation air flap motor diagnostic: direction of rotation: Stop
Right temperature door actuator - direction: Stop
Left temperature door actuator - direction: Stop
Blower motor - speed: 0 %
A/C compressor clutch - inhibit reason: Allowed
Engine coolant temperature: -40 °C
A/C high side pressure sensor: 0 kPa
A/C evaporator temperature sensor - low resolution: -40 °C
A/C request: No
A/C compressor clutch: Disengaged
Passenger compartment air temperature (unfiltered): -40 °C
Passenger compartment air temperature (filtered): -40 °C
Upper left duct air temperature sensor: -40 °C
Lower left duct air temperature sensor: -40 °C
Upper right duct air temperature sensor: -40 °C
Lower right duct air temperature sensor: -40 °C
Blower motor - speed command: 0 %
Ignition voltage: 0.00 V
Front spoiler air inlet motor: Inactive
Rear defogger: Off
A/C compressor - refrigerant solenoid valve command: 0 %
Sunload: 0 W/m²
Sun elevation: 0 °
Sun azimuth: 0 °
Air inlet door - position: 0 Counts
Target left duct temperature: 0 °C
Target right duct temperature: 0 °C
Air inlet flap actuator - command: 0 Counts
Air inlet flap actuator - direction: Stop
Mode door position: 0 Counts
Mode door actuator - command: 0 Counts
Air recirculation flap - position: 0 Counts
Air recirculation flap - command: 0 Counts
Left temperature door - position: 0 Counts
Right temperature door - position: 0 Counts
Right temperature door actuator - desired position: 0 Counts
Left temperature door actuator - desired position: 0 Counts
Air recirculation telltale: Off
Auto HVAC indicator: Off
A/C telltale: --
A/C compressor: Not used
Low refrigerant pressure detected: Inactive
A/C compressor - stuck on: Inactive
A/C evaporator temperature sensor - high resolution: 0.0 °C
Air recirculation mode switch: Inactive
Front defroster switch: Inactive
Auto HVAC - button: Inactive
Enhanced defrost switch: Inactive
Auto recirculation - switch: --
Blower motor switch: --
A/C switch: --
Rear defogger switch: --
Instrument panel vents switch: --
Floor mode switch: --
Left temperature knob - position: 22 °C
Right temperature knob - position: 22 °C
Rear window defogger - telltale: Off
Floor mode indicator: Off
Enhanced defrost indicator: Off
Blower motor - speed 2 indicator: Off
Blower motor - speed 3 indicator: Off
Blower motor - speed 4 indicator: --
Blower motor - speed 5 indicator: --
Blower motor - speed 6 indicator: --
Blower motor - speed 1 indicator: --
Auto recirculation - indicator: --
Front defrost indicator: --
Instrument panel vents indicator: --
Auxiliary heater - output status: Malfunction
Auxiliary heater - request: 0 %
Actuators test
Controls
Air recirculation door position
All Telltales test
Blower motor speed
Front spoiler air inlet motor
Rear defogger
Auxiliary heater request
Auxiliary coolant pump
Mode door position
Air inlet door position
Left temperature door position
Right temperature door position
Left temperature door position