Car, OPEL, Zafira B, 2013, Climate control
Climate control - Climate control - 0
Identification
Code index: 007
Code version: 01
Production date: 20 10 11 26
VIN no: W0L0AHL0875019564
System identification: PREH 0400
System: ECC A3300
Identifier: 02 03
ECU diagnostic address: 99
Software version number: 0AL00/35C68
Part number: 13274233
Hardware number: 13245113
Alpha code: 000
DTC
P1532 [2]: Air conditioner evaporator temperature sensor - circuit low voltage
B0237 [4]: Air distribution flap motor - circuit open
Controls
Clear DTC
Data stream
Solar sensor intensity: 9.98 V
Interior air temperature: 237.73 V
Footwell air outlet temperature: 9.98 V
Interior air outlet temperature: 237.73 V
Evaporator temperature: 237.73 V
Interior air temperature: -1690 °C
Footwell air outlet temperature: -563 °C
Interior air outlet temperature: 2112 °C
System voltage: 5990 V
Blower feedback: 0.06 V
Evaporator temperature: 2112 °C
Air quality sensor: 280 %
A/C compressor feedback: 65315 mA
Air circulation switch: Not active
Auto switch: Not active
Menu control: Not pressed
Defrost switch: Not active
Rear window heating switch: Active
Blower setting: 28 %
A/C compressor stroke release: 65315 mA
Auto LED: Off
Recirculation LED: Off
Defrost LED: Off
Rear window heating LED: Off
LED background illumination level: 34 %
Function key illumination level: 24 %
Air mix flap position: 28 %
Air distribution flap position: 234 °
Air mix flap motor: Not active
Air distribution flap calibration: Not active
Air distribution flap motor: Not active
Recirculation flap position: Recirculation
Outside air temperature: 28 °C
Engine coolant temperature sensor: -22 °C
A/C pressure sensor: 2338 kPa
Engine running status: Unknown
System power mode: Off
Ignition status: Not active
Key-in status: Not active
A/C compressor stroke release: No limitation
Engine speed: 280 rpm
Vehicle speed sensor: 65315 km/h
Dimmed illumination: 24 %
Add-on heater: Not active
Rear window heater status: Not active
Rear window heater request: Not active
A/C request: On
Air distribution flap position:
Air pollution: Medium
Configuration data
Air quality sensor: Not present
Anti theft warning: Present
Actuators test
Controls
LED dimmed illumination test
Recirculation flap motor test
Distribution flap motor test
Blower motor
Air mix flap
Calibrate step motors
Utility
Controls
Edit VIN
Configuration
Controls
Edit mid speed CAN-bus configuration
Edit configuration