Bil, OPEL, Zafira B, 2007, Klima Anlæg

Klima Anlæg - Klima Anlæg - 0

Identifikation

Kodeindeks: 007

Kodeversion: 01

Production date: 20 10 11 26

Stel nr.: W0L0AHL0875019564

Systemidentifikation: PREH 0400

System: ECC A3300

Identificere : 02 03

ECU diagnostic address: 99

Software version number: 0AL00/35C68

Dele nummer: 13274233

Hardware number: 13245113

Alpha code: 000

Fejlkoder

P1532 [2]: Air conditioner evaporator temperature sensor - circuit low voltage

B0237 [4]: Air distribution flap motor - circuit open

Controls

Clear DTC

Levende Data

Solar sensor intensity: 9.98 V

Interior air temperature: 237.73 V

Footwell air outlet temperature: 9.98 V

Interior air outlet temperature: 237.73 V

Evaporator temperature: 237.73 V

Interior air temperature: -1690 °C

Footwell air outlet temperature: -563 °C

Interior air outlet temperature: 2112 °C

Systemspænding: 5990 V

Blower feedback: 0.06 V

Evaporator temperature: 2112 °C

Luftkvalitetsføler: 280 %

A/C compressor feedback: 65315 mA

Air circulation switch: Ikke aktiv

Auto switch: Ikke aktiv

Menu control: Ikke trykket

Defrost switch: Ikke aktiv

Rear window heating switch: Aktiv

Blower setting: 28 %

A/C compressor stroke release: 65315 mA

Auto LED: Sluk

Recirculation LED: Sluk

Defrost LED: Sluk

Rear window heating LED: Sluk

LED background illumination level: 34 %

Function key illumination level: 24 %

Air mix flap position: 28 %

Air distribution flap position: 234 °

Air mix flap motor: Ikke aktiv

Air distribution flap calibration: Ikke aktiv

Air distribution flap motor: Ikke aktiv

Recirculation flap position: Recirkulation

Outside air temperature: 28 °C

Motor kølevæske temperatur føler: -22 °C

A/C pressure sensor: 2338 kPa

Engine running status: Ukendt

Systemstrømstilstand: Sluk

Ignition status: Ikke aktiv

Key-in status: Ikke aktiv

A/C compressor stroke release: No limitation

Motor Hastighed: 280 Omdr.

Køretøjets hastighed sensor: 65315 km/h

Dimmed illumination: 24 %

Add-on heater: Ikke aktiv

Rear window heater status: Ikke aktiv

Rear window heater request: Ikke aktiv

A/C request: Tænd

Air distribution flap position:

Air pollution: Mellem

Konfigurations Data

Luftkvalitetsføler: Ikke tilstede

Anti theft warning: Tilstede

Udgangs test

Controls

LED dimmed illumination test

Recirculation flap motor test

Distribution flap motor test

Blæsermotor

Air mix flap

Calibrate step motors

Muligheder

Controls

Rediger stel nr.

Konfiguration

Controls

Edit mid speed CAN-bus configuration

Redigere konfiguration