Bil, OPEL, Zafira B, 2005, Klima Anlæg
Klima Anlæg - Klima Anlæg - 0
Identifikation
Kodeindeks: 007
Kodeversion: 01
Production date: 20 10 11 26
Stel nr.: W0L0AHL0875019564
Systemidentifikation: PREH 0400
System: ECC A3300
Identificere : 02 03
ECU diagnostic address: 99
Software version number: 0AL00/35C68
Dele nummer: 13274233
Hardware number: 13245113
Alpha code: 000
Fejlkoder
P1532 [2]: Air conditioner evaporator temperature sensor - circuit low voltage
B0237 [4]: Air distribution flap motor - circuit open
Controls
Clear DTC
Levende Data
Solar sensor intensity: 9.98 V
Interior air temperature: 237.73 V
Footwell air outlet temperature: 9.98 V
Interior air outlet temperature: 237.73 V
Evaporator temperature: 237.73 V
Interior air temperature: -1690 °C
Footwell air outlet temperature: -563 °C
Interior air outlet temperature: 2112 °C
Systemspænding: 5990 V
Blower feedback: 0.06 V
Evaporator temperature: 2112 °C
Luftkvalitetsføler: 280 %
A/C compressor feedback: 65315 mA
Air circulation switch: Ikke aktiv
Auto switch: Ikke aktiv
Menu control: Ikke trykket
Defrost switch: Ikke aktiv
Rear window heating switch: Aktiv
Blower setting: 28 %
A/C compressor stroke release: 65315 mA
Auto LED: Sluk
Recirculation LED: Sluk
Defrost LED: Sluk
Rear window heating LED: Sluk
LED background illumination level: 34 %
Function key illumination level: 24 %
Air mix flap position: 28 %
Air distribution flap position: 234 °
Air mix flap motor: Ikke aktiv
Air distribution flap calibration: Ikke aktiv
Air distribution flap motor: Ikke aktiv
Recirculation flap position: Recirkulation
Outside air temperature: 28 °C
Motor kølevæske temperatur føler: -22 °C
A/C pressure sensor: 2338 kPa
Engine running status: Ukendt
Systemstrømstilstand: Sluk
Ignition status: Ikke aktiv
Key-in status: Ikke aktiv
A/C compressor stroke release: No limitation
Motor Hastighed: 280 Omdr.
Køretøjets hastighed sensor: 65315 km/h
Dimmed illumination: 24 %
Add-on heater: Ikke aktiv
Rear window heater status: Ikke aktiv
Rear window heater request: Ikke aktiv
A/C request: Tænd
Air distribution flap position:
Air pollution: Mellem
Konfigurations Data
Luftkvalitetsføler: Ikke tilstede
Anti theft warning: Tilstede
Udgangs test
Controls
LED dimmed illumination test
Recirculation flap motor test
Distribution flap motor test
Blæsermotor
Air mix flap
Calibrate step motors
Muligheder
Controls
Rediger stel nr.
Konfiguration
Controls
Edit mid speed CAN-bus configuration