Bil, NISSAN, LEAF (ZE0), 2014-, Latin America , Africa, Motor control
Motor - Motor control - 0
Identifikation
Stel nr.: AZE0-062145
Dele nummer: 291A0-1LA0A
Diagnostic ID: 01
Supplier number: 44 A1 02
Hardware number: 01 00 00 42 16
Software nummer: C3 00
Udgavenummer: 32 01
Kalibreringsnummer: 00 00
Manufacturer identification code reprogramming: "
Supplier number reprogramming:
CRC value: 82 01
Number of reprogramming: 22
Fejlkoder
P0AF0: Drive motor inverter temperature sensor "A" - circuit high voltage
Controls
Clear DTC
Levende Data
Nummer af fejlkoder: 0
Torque limitation: 0 %
Torque limitation: max: -317.5 N·m
Torque limitation: min: -317.5 N·m
Motor temperature: -40 °C
Motor temperature max value: -40 °C
Motor temperature min value: -40 °C
Motor overheating number: 0
Inverter temperature 2: -40 °C
Inverter temperature max: -40 °C
Inverter temperature min: -40 °C
Inverter overheating number: 0 °C
Motor inverter temperature sensor 5: -40 °C
Inverter temperature 5 max value: -40 °C
Inverter temperature 5 min value: -40 °C
Inverter temperature 4: -40 °C
Inverter temperature 4 max value: -40 °C
Inverter temperature 4 min value: -40 °C
Inverter overheating 4 number: 0 °C
Inverter temperature 1: -40 °C
Motor inverter temperature sensor 3: -40 °C
12V battery voltage: 0.00 V
Invereter input high voltage : 0.00 V
Battery Total voltage: 0.00 V
Torque command: 0.0 N·m
Inside torque command: 0.0 N·m
Vibration torque command: 0.0 N·m
Motor speed: 0 Omdr.
Target D-axis motor current: 0.0 A
Motor D-axis current: 0.0 A
Target Q-axis motor current: 0.0 A
Drive motor Q-axis current: 0.0 A
Target D-axis motor voltage: 0.00 V
Target Q-axis motor voltage: 0.00 V
Phase current 3: 0.0 A
Phase current U: 0.0 A
Phase current V: 0.0 A
Phase current W: 0.0 A
Phase angle: 0.0 °
Sequence mode: 0
Carrier frequency: 5 kHz
Output limit inverter temperature: Limit
Sleep refuse signal:
Output limit motor temperature: Limit
IGBT high temperature detected: Sluk
Motor control status: NG
Restart: NG
Status active discharge: Sluk
Charge permission flag: NG
Charge monitoring: Ikke komplet
Failsafe state: Normal
Charge relay ready request: Sluk
Stop and start function request: Stop
High voltage supply: Stop
DPA request: Ikke anmodet
Shift position (VCM): N
Shift position (E-shift): Hold
Vibration contol request: Normal
Discharge:
Command wake up sleep: Sleep
System cut off complete: Ikke komplet
Diag prohibit: Sluk
PWM off request: Normal
CAN diagnostic support monitor
Bus off diagnostic: 83
Transmit diag: 0
Muligheder
Controls
Traction motor/inverter output limit reason reset