PKW, MITSUBISHI, TRITON , L200 (KJ, L, K), 2016, KV3T, JNHFPL, Air Conditioner

Klimaregelung - Air Conditioner - 0

Identifikation

Identifikator: 00 01

ECU origin: 04

Lieferantennummer: 65

Steuergerät ID: 00

Diagnoseversion: 01

Hardwareversion: 00 01

Softwareversion: 00 01 01

Ersatzteilnummer: 7820A744

Softwarenummer: FFFFFF

FIN (ursprünglich): JMBXTGF3WDZ003948

Class: TG

Modell: Outlander / GF

Typ: GF3W

Modelljahr: 2013

FIN: JMBXTGF3WDZ003948

Kalibrierung ID: --

CVN: --

Fehlercode

B10C0: Innenraum-Temperatursensor - Kurzschluss

U0184: Lost communication with audio module

Controls

Fehlercode löschen

Ist-Werte

Interior temperature sensor: 20.0 °C

Air thermo sensor: 58.4 °C

Fotosensor: 715.0 W/m2

Geber für Kühlmitteltemperatur: 215 °C

Geber für Außentemperatur: 16.5 °C

Motordrehzahl: 15 UpM

Fahrgeschwindigkeit: 512 km/h

Driver air mix flap potentiometer: 2048 Pulse

Passenger air mix flap potentiometer: 2 Pulse

Mode selection damper: 65274 Pulse

In/out select damper: 0 Pulse

Front blower fan: 0 Schritte

Target front blower fan: 0 Schritte

Mode selection damper (Target): Face

In/out select damper (target): Fresh

A/C compressor drive request: EIN

Air conditioning switch: EIN

Schalter Heckscheibenheizung: EIN

Idle up request: Low (Hot)

PTC heater operation flag: EIN

A/T lockup open request: EIN

Driver seat setting temperature: 7.5 °C

Set temperature (Passenger side): 2.0 °C

Auto stop & go (AS&G): Engine start unable

Idle stop disable flag: EIN

Idle stop cancellation request: EIN

A/C compressor drive flag:

Ignition position information: EIN

PTC heater 1 use times: 49 Count

In/out air selection damper motor drive: 100488 Pulse

Mode selection damper motor drive: 128 Pulse

Driver side air mixing damper motor drive: 16777288 Pulse

Passenger air mixing damper drive: 1 Pulse

Driver A/M damper max cool: 2577 Count

Driver A/M damper max hot: 0 Count

System operation time: 290 sec

Passenger A/M damper max cool: 10 Count

Passenger A/M damper max hot: 30 Count

Compressor use times: 128 Count

Rear defogger use times: 143 Count

A/C use rate: 1275 sec

Compressor operation rate: 75 sec

Recirculation use rate: 1275 min

Maximum engine coolant temperature: 215 °C

Engine high speed time: 1275 sec

Passenger temperature down switch operation times: 0 Count

Fan up switch operation times: 16777215 Count

Fan down switch operation times: 355 Count

Mode select switch operation times: 271 Count

Defogger switch operation times: 16711935 Count

A/C operation times: 128 Count

Driver temperature up switch operation times: 0 Count

In/out air c/o operation times: 255 Count

Driver temperature down switch operation times: 0 Count

Passenger temperature up switch operation times: 0 Count

Fan M2 driving time: 0 sec

Fan high driving time: 55 sec

Fan lo driving time: 0 sec

Fan M1 driving time: 75 sec

Stellgliedtest

Controls

Idle up request

In/out select damper

Mode selection damper

Schalter für Klimaanlage

Rear defogger switch

A/T lockup open request

PTC heater

Driver A/M damper reset request

Passenger A/M damper reset request

Driver air mix damper motor

Passenger side air mixing damper motor drive

Front blower fan