Bil, MITSUBISHI, i-MiEV (HA0), 2017, ZAA-HA4W, LDDB, COMP&HTR HEAT PUMP

Varmer - COMP&HTR HEAT PUMP - 0

Identifikation

Identificere : 00 01

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnose version: 01

Hardware version nummer: 00 01

Softwareversion: 00 01 01

Dele nummer: 7820A744

Software nummer: FFFFFF

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

B10C0: Interrior air temperature sensor - circuit shorted

Controls

Clear DTC

Levende Data

Compressor speed: 250 Omdr.

Compressor drive history flag: Sluk

Climate power save active flag: Tænd

Cooling fan request (Climate): Lav

Compressor inverter input power: 600 W

Refrigerant pressure sensor: 0.21 MPa

Inner condenser refrigerant temperature: -10.0 °C

Outer condenser refrigerant temperature: 65.0 °C

Frost formation flag: Sluk

2 way solenoid valve: Sluk

Defrosting mode active flag: Sluk

3 way solenoid valve: Tænd

PTC heater: Sluk

Battery cooling request flag: Sluk

Pre A/C mode: SNA

Battery cooling control mode: Ventilation

Pre A/C control permit flag: Sluk

In/out select damper: Recirkulation

MAX switch control status: Tænd

A/C-kontakt: Sluk

In/out select damper switch status: Fresh

MAX switch status: Sluk

Temperature control dial:

Air outlet c/o potentiometer:

Blower fan output: Sluk

Interior temperature sensor: -16.0 °C

Ambient temperature sensor (Meter): -40.0 °C

Ambient temperature sensor (CAN Output): -29.0 °C

Air thermo sensor: -16.0 °C

Battery cooling active flag: Sluk

Pre A/C mode active flag: Sluk

Udgangs test

Controls

Battery cooling flap motor

In/out select damper

Cooling fan (Climate)

PTC heater relay (320W)

PTC heater relay (160W)

Cooling mode

Heating mode

Defrost

Muligheder

Controls

Compressor drive history reset