Bil, MITSUBISHI, i-MiEV (HA0), 2017, HA4W, LDDR6, COMP&HTR COMP&HTR

Varmer - COMP&HTR COMP&HTR - 0

Identifikation

Identificere : 00 06

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnose version: 06

Hardware version nummer: 00 01

Softwareversion: 00 01 01

Dele nummer: 7820A744

Software nummer: FFFFFF

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

B10C0: Interrior air temperature sensor - circuit shorted

U0184: Lost communication with audio module

Controls

Clear DTC

Levende Data

Compressor speed: 32768 Omdr.

Compressor drive history flag: Tænd

Climate power save active flag: Sluk

Cooling fan request (Climate): Sluk

Compressor inverter input power: 0 W

Refrigerant pressure sensor: 3.57 MPa

Electrical water heater test result: Not completed

Electrical water heater spec. judgment: Not completed

Electric water pump output: Sluk

Electrical water heater: 10200 W

Electrical water heater inlet sensor: 63.8 °C

Electrical water heater outlet sensor: -34.0 °C

Battery cooling request flag: Sluk

Pre A/C mode: SNA

Battery cooling control mode: Ventilation

Battery heating request flag: Sluk

Pre A/C control permit flag: Sluk

In/out select damper: Fresh

MAX switch control status: Sluk

A/C-kontakt: Sluk

In/out select damper switch status: Fresh

MAX switch status: Sluk

Temperature control dial:

Air outlet c/o potentiometer: SNA

Blower fan output:

Interior temperature sensor: 16.0 °C

Ambient temperature sensor (Meter): 87.5 °C

Ambient temperature sensor (CAN Output): 47.5 °C

Air thermo sensor: 47.8 °C

Water temperature sensor (HVAC): 111.8 °C

Frost protection active flag: Sluk

Battery heating active flag: Tænd

Air purge mode active flag: Sluk

Battery cooling active flag: Sluk

Pre A/C mode active flag: Sluk

Udgangs test

Controls

Battery cooling flap motor

In/out select damper

Cooling fan (Climate)

Electic water heater test mode

Muligheder

Controls

Compressor drive history reset