PKW, MITSUBISHI, i-MiEV (HA0), 2015, ZAA-HA4W, LDDB, CMU4

Hochspannungs- batterie - CMU4 - 0

Identifikation

Identifikator: 00 06

ECU origin: 04

Lieferantennummer: 85

Steuergerät ID: 00

Diagnoseversion: 06

Hardwareversion: 01 02

Softwareversion: 02 01 13

Ersatzteilnummer: 8634A049

Softwarenummer: 8634A04904

FIN (ursprünglich): --

Class: --

Modell: --

Typ: --

Modelljahr: --

FIN: --

Kalibrierung ID: --

CVN: --

Fehlercode

Controls

Fehlercode löschen

Ist-Werte

Cell 002 voltage: 0.000 V

Cell 003 voltage: 0.000 V

Cell 004 voltage: 0.000 V

Cell 005 voltage: 0.000 V

Cell 006 voltage: 0.000 V

Cell 007 voltage: 0.000 V

Cell 008 voltage: 0.000 V

Cell 009 voltage: 0.000 V

Cell 010 voltage: 0.000 V

Cell 011 voltage: 0.000 V

Module voltage: 0.000 V

Cell 012 voltage: 0.000 V

Cell total voltage: 0.000 V

Voltage diff. (Module-Total cell): 0.000 V

Cell 001 voltage: 0.000 V

Temperature sensor 2 underflow: Normal

Temperature sensor 6 underflow: Normal

Temperature sensor 3 underflow: Normal

Temperature sensor 1 overflow: Normal

Temperature sensor 4 underflow: Normal

Temperature sensor 2 overflow: Normal

Temperature sensor 5 underflow: Normal

Temperature sensor 3 overflow: Normal

Temperature sensor 4 overflow: Normal

EEPROM Fail (Learning data read): Normal

Temperature sensor 5 overflow: Normal

CAN controller: Normal

Temperature sensor 6 overflow: Normal

Bat-CAN (Bus off): Normal

EEPROM Fail (failure info read): Normal

Balancer drive time fail (20h): Normal

Monitor IC: Initializing process: Normal

Monitor IC: Self diagnosis: Normal

Monitor IC: Cell volt AD convert: Normal

Monitor IC: Register config: Normal

Monitor IC: GP AD conversion: Normal

Monitor IC: CRC: Normal

Monitor IC: Balancer: Normal

Monitor IC: AD conversion timeout: Normal

Self diag: Charge pump circuit: Normal

Referenzspannung: Normal

Self diag: Measurement accuracy: Normal

Cell voltage measurement: Normal

Self diag: AD convert output data: Normal

Temperature measurement power supply: Normal

Self diag: AD result register: Normal

Cell 01 measurement terminal: Normal

Cell 02 measurement terminal: Normal

Cell 06 measurement terminal: Normal

Cell 03 measurement terminal: Normal

Cell 07 measurement terminal: Normal

Cell 04 measurement terminal: Normal

Cell 08 measurement terminal: Normal

Cell 05 measurement terminal: Normal

Cell 09 measurement terminal: Normal

Cell 10 measurement terminal: Normal

Temperature 02 terminal open: Normal

Cell 11 measurement terminal: Normal

Temperature 03 terminal open: Normal

Cell 12 measurement terminal: Normal

Temperature 04 terminal open: Normal

Temperature 01 terminal open: Normal

Temperature 05 terminal open: Normal

Temperature 06 terminal open: Normal

Temperature 04 terminal short: Normal

Temperature 01 terminal short: Normal

Temperature 05 terminal short: Normal

Temperature 02 terminal short: Normal

Temperature 06 terminal short: Normal

Temperature 03 terminal short: Normal

Cell 01 voltage underflow: Normal

Cell 02 voltage underflow: Normal

Cell 06 voltage underflow: Normal

Cell 03 voltage underflow: Normal

Cell 07 voltage underflow: Normal

Cell 04 voltage underflow: Normal

Cell 08 voltage underflow: Normal

Cell 05 voltage underflow: Normal

Cell 09 voltage underflow: Normal

Cell 10 voltage underflow: Normal

Cell 02 voltage overflow: Normal

Cell 11 voltage underflow: Normal

Cell 03 voltage overflow: Normal

Cell 12 voltage underflow: Normal

Cell 04 voltage overflow: Normal

Cell 01 voltage overflow: Normal

Cell 05 voltage overflow: Normal

Cell 06 voltage overflow: Normal

Cell 10 voltage overflow: Normal

Cell 07 voltage overflow: Normal

Cell 11 voltage overflow: Normal

Cell 08 voltage overflow: Normal

Cell 12 voltage overflow: Normal

Cell 09 voltage overflow: Normal

Temperature sensor 1 underflow: Normal

Dienst­programme

Controls

EEPROM Fail information