PKW, MITSUBISHI, i-MiEV (HA0), 2015, ZAA-HA4W, LDDB, COMP&HTR COMP&HTR

Heizer - COMP&HTR COMP&HTR - 0

Identifikation

Identifikator: 00 06

ECU origin: 04

Lieferantennummer: 65

Steuergerät ID: 00

Diagnoseversion: 06

Hardwareversion: 00 01

Softwareversion: 00 01 01

Ersatzteilnummer: 7820A744

Softwarenummer: FFFFFF

FIN (ursprünglich): --

Class: --

Modell: --

Typ: --

Modelljahr: --

FIN: --

Kalibrierung ID: --

CVN: --

Fehlercode

B10C0: Innenraum-Temperatursensor - Kurzschluss

U0184: Lost communication with audio module

Controls

Fehlercode löschen

Ist-Werte

Compressor speed: 32768 UpM

Compressor drive history flag: EIN

Climate power save active flag: AUS

Cooling fan request (Climate): AUS

Compressor inverter input power: 0 W

B12 (Kältemittel-Drucksensor): 3.57 MPa

Electrical water heater test result: Nicht erfolgt

Electrical water heater spec. judgment: Nicht erfolgt

Electric water pump output: AUS

Electrical water heater: 10200 W

Electrical water heater inlet sensor: 63.8 °C

Electrical water heater outlet sensor: -34.0 °C

Battery cooling request flag: AUS

Pre A/C mode: SNA

Battery cooling control mode: Entlüftung

Battery heating request flag: AUS

Pre A/C control permit flag: AUS

In/out select damper: Fresh

MAX switch control status: AUS

Schalter für Klimaanlage: AUS

In/out select damper switch status: Fresh

MAX switch status: AUS

Temperature control dial:

Air outlet c/o potentiometer: SNA

Blower fan output:

Interior temperature sensor: 16.0 °C

Ambient temperature sensor (Meter): 87.5 °C

Ambient temperature sensor (CAN Output): 47.5 °C

Air thermo sensor: 47.8 °C

Water temperature sensor (HVAC): 111.8 °C

Frost protection active flag: AUS

Battery heating active flag: EIN

Air purge mode active flag: AUS

Battery cooling active flag: AUS

Pre A/C mode active flag: AUS

Stellgliedtest

Controls

Battery cooling flap motor

In/out select damper

Cooling fan (Climate)

Electic water heater test mode

Dienst­programme

Controls

Compressor drive history reset