Car, MITSUBISHI, i-MiEV (HA0), 2015, HA4W, LDDR6, COMP&HTR COMP&HTR

Heater - COMP&HTR COMP&HTR - 0

Identification

Identifier: 00 06

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnostic version: 06

Hardware version number: 00 01

Software version: 00 01 01

Part number: 7820A744

Software number: FFFFFF

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

VIN no: --

Calibration ID: --

Calibration verification number (CVN): --

DTC

B10C0: Interrior air temperature sensor - circuit shorted

U0184: Lost communication with audio module

Controls

Clear DTC

Data stream

Compressor speed: 32768 rpm

Compressor drive history flag: On

Climate power save active flag: Off

Cooling fan request (Climate): Off

Compressor inverter input power: 0 W

Refrigerant pressure sensor: 3.57 MPa

Electrical water heater test result: Not completed

Electrical water heater spec. judgment: Not completed

Electric water pump output: Off

Electrical water heater: 10200 W

Electrical water heater inlet sensor: 63.8 °C

Electrical water heater outlet sensor: -34.0 °C

Battery cooling request flag: Off

Pre A/C mode: SNA

Battery cooling control mode: Ventilation

Battery heating request flag: Off

Pre A/C control permit flag: Off

In/out select damper: Fresh

MAX switch control status: Off

A/C switch: Off

In/out select damper switch status: Fresh

MAX switch status: Off

Temperature control dial:

Air outlet c/o potentiometer: SNA

Blower fan output:

Interior temperature sensor: 16.0 °C

Ambient temperature sensor (Meter): 87.5 °C

Ambient temperature sensor (CAN Output): 47.5 °C

Air thermo sensor: 47.8 °C

Water temperature sensor (HVAC): 111.8 °C

Frost protection active flag: Off

Battery heating active flag: On

Air purge mode active flag: Off

Battery cooling active flag: Off

Pre A/C mode active flag: Off

Actuators test

Controls

Battery cooling flap motor

In/out select damper

Cooling fan (Climate)

Electic water heater test mode

Utility

Controls

Compressor drive history reset