PKW, MITSUBISHI, i-MiEV (HA0), 2013, HA4W, LDDL6, CMU11
Hochspannungs- batterie - CMU11 - 0
Identifikation
Identifikator: 00 01
ECU origin: 04
Lieferantennummer: 64
Steuergerät ID: 00
Diagnoseversion: 01
Hardwareversion: 41 01
Softwareversion: 2C 00 03
Ersatzteilnummer: 8637A695
Softwarenummer: 8634A04904
FIN (ursprünglich): --
Class: --
Modell: --
Typ: --
Modelljahr: --
FIN: --
Kalibrierung ID: --
CVN: --
Fehlercode
Controls
Fehlercode löschen
Ist-Werte
Cell B voltage: 0.000 V
Cell C voltage: 0.000 V
Cell D voltage: 0.000 V
Cell E voltage: 0.000 V
Cell F voltage: 0.000 V
Cell G voltage: 0.000 V
Cell H voltage: 0.000 V
Module voltage: 0.000 V
Cell total voltage: 0.000 V
Voltage diff. (Module-Total cell): 0.000 V
Cell A voltage: 0.000 V
Cell monitor IC: Normal
Temperature sensor 1 (open): Normal
Voltage sensor: Normal
Temperature sensor 2 (open): Normal
Reference low voltage: Normal
Temperature sensor 3 (open): Normal
Reference high voltage: Normal
Temperature sensor 4 (open): Normal
Temperature sensor 5 (open): Normal
Temperature sensor 3 (short): Normal
Temperature sensor 6 (open): Normal
Temperature sensor 4 (short): Normal
Temperature sensor 1 (short): Normal
Temperature sensor 5 (short): Normal
Temperature sensor 2 (short): Normal
Temperature sensor 6 (short): Normal
Cell A voltage underflow: Normal
Cell E voltage underflow: Normal
Cell B voltage underflow: Normal
Cell F voltage underflow: Normal
Cell C voltage underflow: Normal
Cell G voltage underflow: Normal
Cell D voltage underflow: Normal
Cell H voltage underflow: Normal
Cell A voltage overflow: Normal
Cell E voltage overflow: Normal
Cell B voltage overflow: Normal
Cell F voltage overflow: Normal
Cell C voltage overflow: Normal
Cell G voltage overflow: Normal
Cell D voltage overflow: Normal
Cell H voltage overflow: Normal
Temperature sensor 1 underflow: Normal
Temperature sensor 5 underflow: Normal
Temperature sensor 2 underflow: Normal
Temperature sensor 6 underflow: Normal
Temperature sensor 3 underflow: Normal
Temperature sensor 1 overflow: Normal
Temperature sensor 4 underflow: Normal
Temperature sensor 2 overflow: Normal
Temperature sensor 3 overflow: Normal
Temperature sensor 4 overflow: Normal
EEPROM Fail (Learning data read): Normal
Temperature sensor 5 overflow: Normal
CAN controller: Normal
Temperature sensor 6 overflow: Normal
Cell G connection terminal: Normal
Cell A connection terminal: Normal
A/D conversion (Reference VOLT.): Normal
Cell C connection terminal: Normal
A/D conversion (Temperature sensor 1): Normal
Cell E connection terminal: Normal
A/D conversion (Temperature sensor 2): Normal
A/D conversion (Temperature sensor 3): Normal
A/D conversion (Module voltage): Normal
A/D conversion (Temperature sensor 4): Normal
Balancer drive time fail (20h): Normal
A/D conversion (Temperature sensor 5): Normal
A/D conversion (Temperature sensor 6): Normal
Dienstprogramme
Controls
EEPROM Fail information