PKW, MITSUBISHI, PHEV (GG), 2022, GG3W, XDHHZLCS, Air Conditioner

Klimaregelung - Air Conditioner - 0

Identifikation

Identifikator: 00 01

ECU origin: 04

Lieferantennummer: 65

Steuergerät ID: 00

Diagnoseversion: 01

Hardwareversion: 00 01

Softwareversion: 00 01 01

Ersatzteilnummer: 7820A744

Softwarenummer: FFFFFF

FIN (ursprünglich): JMBXTGF3WDZ003948

Class: TG

Modell: Outlander / GF

Typ: GF3W

Modelljahr: 2014

FIN: JMBXTGF3WEZ003948

Kalibrierung ID: --

CVN: --

Fehlercode

B1115: Electric water pump (EWP) malfunction

Controls

Fehlercode löschen

Ist-Werte

Interior temperature sensor: 18.0 °C

Air thermo sensor: 27.8 °C

Drucksensor: 2.24 MPa

Fotosensor: 99.0 W/m2

Geber für Kühlmitteltemperatur: 82 °C

Geber für Außentemperatur: 6.5 °C

Generator use rate: 0 %

Battery cooling air thermo sensor: 7.0 °C

Electrical water heater inlet sensor: 64.0 °C

Electrical water heater outlet sensor: 67.0 °C

Motordrehzahl: 175 UpM

Fahrgeschwindigkeit: 77 km/h

Supply power for A/C: 5120 W

High voltage battery current: -325.72 A

High voltage battery voltage: 0.0 V

Driver air mix flap potentiometer: 7 %

Passenger air mix flap potentiometer: 5 %

Air outlet c/o potentiometer: 12 %

In/out select damp potentiometer: 0 %

Front blower fan: 0 Schritte

Target front blower fan: 0 Schritte

Air outlet c/o potentiometer (target): DEF

In/out select damp poten (target): Fresh

A/C compressor drive request: AUS

Air conditioning switch: AUS

Solenoid valve output: EIN

Schalter Heckscheibenheizung: AUS

Kondensator-Gebläse: 8 %

Engine start request: AUS

Electrical water heater PTC1 output: AUS

A/C inverter switch: AUS

Electrical water heater PTC2 output: AUS

Electrical water heater PTC3 output: AUS

Compressor stop eternity: AUS

Compressor over current: AUS

Compressor drive status: Normal

Compressor controller fail: AUS

Compressor sensor fail: AUS

Compressor heat protection: AUS

Compressor power fail: AUS

Compressor voltage fail: Normal

Compressor drive flag (ignition cycle): AUS

Compressor speed: 0 UpM

Verdichter: 0 W

Electrical water heater level: 4 Schritte

Electrical water heater: 3200 W

Elektrische Wasserpumpe : 100 %

High pressure fail flag: EIN

Low pressure fail flag: EIN

Refrigerant leak (Low pressure): Wird durchgeführt

Refrigerant leak (level 20%): Fehler

Driver seat setting temperature: 67.0 °C

Set temperature (Passenger side): 67.5 °C

Compressor drive history flag: AUS

Battery cooling drive history flag: AUS

Electrical water heater test result: Fail

ELC water pump drive his. flag: AUS

Heated windshield test mode flag: AUS

Heated windscreen equipment: Nicht vorhanden

ECO mode: ECO

Wiper operation flag: AUS

Ignition/electric motor switch position information: EIN

Power source voltage: 14.5 V

IOD fuse eqipment flag: EIN

Crash down signal: AUS

Pre air conditioning signal: AUS

High voltage ready signal: EIN

Battery cooling request signal: AUS

Shut down signal: EIN

Engine work time: 11950120 sec

System operation time: 201490 min

Ignition switch/Electric motor switch on time: 11983085 sec

Battery cooling time: 552935 sec

Compressor high speed drive time: 35370 sec

Solenoid valve operation counter: 3342 Count

Höchstdruck: 2.04 MPa

High pressure cut times: 0 Count

Compressor drive time: 2755230 sec

Compressor high pressure drive time: 0 sec

Electrical water heater PTC3 drive time: 1157770 sec

Elektrische Wasserpumpe : 6528275 sec

High water temperature: 327675 sec

High water temperature cut counter: 0 Count

Maximum coolant temperature: 112 °C

Electrical water heater inlet max temperature: 101 °C

Electrical water heater outlet max temperature: 102 °C

Electrical water heater PTC1 drive time: 1722560 sec

Electrical water heater PTC2 drive time: 1614535 sec

Fan high driving time: 304260 sec

Fan lo driving time: 7581765 sec

Fan M1 driving time: 1298885 sec

Fan M2 driving time: 402325 sec

Stellgliedtest

Controls

In/out select damper

Air outlet c/o damper

Kondensator-Gebläse

Schalter für Klimaanlage

Rear defogger switch

Electronic water heater test

Solenoid Valve Test

Engine start request

Elektrische Wasserpumpe

Front blower fan

Driver air mix damper motor

As air mix damper motor

Dienst­programme

Controls

Compressor drive history reset

Battery cooling drive history reset

ELC water pump drive his. reset

Heated windscreen test mode

Heated windscreen test mode stop

Electronic water heater test