Bil, MITSUBISHI, PHEV (GG), 2020, GG3W, XDPHZL6, BMU(SUB)

Strøm kilde kontrol - BMU(SUB) - 0

Identifikation

Identificere : 00 00

ECU origin: 04

Supplier number: 85

ECU ID: 00

Diagnose version: 00

Hardware version nummer: 86 00

Softwareversion: 86 00 04

Dele nummer: 8638A037

Software nummer: 8637A69600

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

P1A4C: OR line voltage

Controls

Clear DTC

Levende Data

Battery heating wakeup signal: Tænd

Leak sensor output (Precheck): Tænd

Max internal resistance: 14.0 mOhm

Min internal resistance: 0.0 mOhm

OR power supply voltage: 17.5 V

IGCT power supply voltage: 17.5 V

Battery cooling fan rotations: 3840 Omdr.

Insulation resistance: -- kOhm

Cell 049 voltage: 0.014 V

Cell 050 voltage: 2.164 V

Cell 051 voltage: 0.007 V

Cell 052 voltage: 0.037 V

Cell 053 voltage: 0.008 V

Cell 004 voltage: 0.031 V

Cell 054 voltage: 0.140 V

Cell 055 voltage: 0.064 V

Cell 005 voltage: 0.173 V

Cell 072 voltage: 0.007 V

Cell 073 voltage: 0.010 V

Cell 006 voltage: 0.027 V

Cell 074 voltage: 1.000 V

Cell 075 voltage: 0.006 V

Cell 076 voltage: 0.000 V

Cell 077 voltage: 0.006 V

Cell 078 voltage: 0.010 V

Cell 079 voltage: 0.135 V

Cell 007 voltage: 0.014 V

Cell 084 voltage: 0.010 V

Cell 085 voltage: 0.002 V

Cell 086 voltage: 0.221 V

Cell 087 voltage: 0.006 V

Cell 088 voltage: 0.013 V

Cell 089 voltage: 0.266 V

Cell 090 voltage: 0.512 V

Cell 091 voltage: 0.005 V

Cell 096 voltage: 0.013 V

Cell 097 voltage: 0.008 V

Cell 098 voltage: 0.010 V

Cell 099 voltage: 0.015 V

Cell 100 voltage: 0.005 V

Cell 101 voltage: 0.006 V

Cell 102 voltage: 0.001 V

Cell 103 voltage: 0.017 V

Cell 108 voltage: 0.170 V

Cell 109 voltage: 0.170 V

Cell 110 voltage: 0.003 V

Cell 111 voltage: 0.170 V

Cell 112 voltage: 0.135 V

Cell 113 voltage: 0.003 V

Cell 114 voltage: 0.018 V

Cell 115 voltage: 0.017 V

Cell 120 voltage: 0.013 V

Cell 121 voltage: 0.008 V

Cell 122 voltage: 0.015 V

Cell 123 voltage: 0.271 V

Cell 124 voltage: 0.135 V

Cell 125 voltage: 0.010 V

Cell 126 voltage: 0.010 V

Cell 127 voltage: 0.022 V

Cell 012 voltage: 0.004 V

Cell 013 voltage: 0.014 V

Cell 000 voltage: 65.535 V

Cell 014 voltage: 0.012 V

Cell 015 voltage: 0.250 V

Cell 016 voltage: 0.021 V

Cell 017 voltage: 9.524 V

Cell 018 voltage: 33.942 V

Cell 019 voltage: 0.135 V

Cell 001 voltage: 0.018 V

Cell 024 voltage: 0.008 V

Cell 025 voltage: 0.008 V

Cell 026 voltage: 0.006 V

Cell 027 voltage: 0.120 V

Cell 028 voltage: 0.068 V

Cell 029 voltage: 0.133 V

Cell 030 voltage: 0.119 V

Cell 031 voltage: 8.526 V

Cell 002 voltage: 0.034 V

Cell 036 voltage: 0.012 V

Cell 037 voltage: 0.168 V

Cell 038 voltage: 0.135 V

Cell 039 voltage: 0.069 V

Cell 040 voltage: 65.280 V

Cell 041 voltage: 0.009 V

Cell 042 voltage: 0.053 V

Cell 043 voltage: 0.002 V

Cell 003 voltage: 0.038 V

Cell 048 voltage: 0.146 V

Module temperature 08: 19 °C

Module temperature 09: 18 °C

Module temperature 10: 18 °C

Module temperature 12: 18 °C

Module temperature 13: 18 °C

Module temperature 14: 19 °C

Module temperature 15: 20 °C

Module temperature 16: 19 °C

Module temperature 18: 19 °C

Module temperature 19: 20 °C

Module temperature 20: 19 °C

Module temperature 21: 18 °C

Module temperature 22: 18 °C

Module temperature 24: 18 °C

Module temperature 25: 18 °C

Module temperature 26: 18 °C

Module temperature 27: 19 °C

Module temperature 00: 21 °C

Module temperature 28: 19 °C

Module temperature 36: 18 °C

Module temperature 37: 19 °C

Module temperature 01: 20 °C

Module temperature 38: 19 °C

Module temperature 39: 18 °C

Module temperature 40: 18 °C

Module temperature 42: 18 °C

Module temperature 43: 18 °C

Module temperature 44: 19 °C

Module temperature 45: 20 °C

Module temperature 46: 19 °C

Module temperature 02: 20 °C

Module temperature 48: 19 °C

Module temperature 49: 20 °C

Module temperature 50: 19 °C

Module temperature 51: 18 °C

Module temperature 52: 18 °C

Module temperature 54: 18 °C

Module temperature 55: 18 °C

Module temperature 56: 19 °C

Module temperature 57: 20 °C

Module temperature 03: 20 °C

Module temperature 58: 19 °C

Module temperature 60: 19 °C

Module temperature 61: 20 °C

Module temperature 62: 20 °C

Module temperature 63: 20 °C

Module temperature 64: 22 °C

Module temperature 04: 20 °C

Module temperature 06: 19 °C

Module temperature 07: 20 °C

Muligheder

Controls

Leak sensor precheck

Battery heating wakeup signal output