Bil, MITSUBISHI, PHEV (GG), 2020, GG2W, XDHHZL3M, Air Conditioner
Klima Anlæg - Air Conditioner - 0
Identifikation
Identificere : 00 01
ECU origin: 04
Supplier number: 65
ECU ID: 00
Diagnose version: 01
Hardware version nummer: 00 01
Softwareversion: 00 01 01
Dele nummer: 7820A744
Software nummer: FFFFFF
VIN no (original): JMBXTGF3WDZ003948
Class: TG
Model: Outlander / GF
Type: GF3W
Model year: 2014
Stel nr.: JMBXTGF3WEZ003948
Calibration ID: --
Calibration verification number (CVN): --
Fejlkoder
B1115: Electric water pump (EWP) malfunction
Controls
Clear DTC
Levende Data
Interior temperature sensor: 18.0 °C
Air thermo sensor: 27.8 °C
Pressure sensor: 2.24 MPa
Photo sensor: 99.0 W/m2
Motor kølevæske temperatur føler: 82 °C
Ambient temperature sensor: 6.5 °C
Generator use rate: 0 %
Battery cooling air thermo sensor: 7.0 °C
Electrical water heater inlet sensor: 64.0 °C
Electrical water heater outlet sensor: 67.0 °C
Motor Hastighed: 175 Omdr.
Køretøjs hastighed : 77 km/h
Supply power for A/C: 5120 W
High voltage battery current: -325.72 A
High voltage battery voltage: 0.0 V
Driver air mix flap potentiometer: 7 %
Passenger air mix flap potentiometer: 5 %
Air outlet c/o potentiometer: 12 %
In/out select damp potentiometer: 0 %
Front blower fan: 0 steps
Target front blower fan: 0 steps
Air outlet c/o potentiometer (target): DEF
In/out select damp poten (target): Fresh
A/C compressor drive request: Sluk
Air conditioning switch: Sluk
Solenoid valve output: Tænd
Bagrudeafdugningskontakt: Sluk
Condenser fan: 8 %
Engine start request: Sluk
Electrical water heater PTC1 output: Sluk
A/C inverter switch: Sluk
Electrical water heater PTC2 output: Sluk
Electrical water heater PTC3 output: Sluk
Compressor stop eternity: Sluk
Compressor over current: Sluk
Compressor drive status: Normal
Compressor controller fail: Sluk
Compressor sensor fail: Sluk
Compressor heat protection: Sluk
Compressor power fail: Sluk
Compressor voltage fail: Normal
Compressor drive flag (ignition cycle): Sluk
Compressor speed: 0 Omdr.
Compressor: 0 W
Electrical water heater level: 4 steps
Electrical water heater: 3200 W
Electric water pump: 100 %
High pressure fail flag: Tænd
Low pressure fail flag: Tænd
Refrigerant leak (Low pressure): Igang
Refrigerant leak (level 20%): Fejl
Driver seat setting temperature: 67.0 °C
Set temperature (Passenger side): 67.5 °C
Compressor drive history flag: Sluk
Battery cooling drive history flag: Sluk
Electrical water heater test result: Fail
ELC water pump drive his. flag: Sluk
Heated windshield test mode flag: Sluk
Heated windscreen equipment: Ikke tilstede
ECO mode: ECO
Wiper operation flag: Sluk
Ignition/electric motor switch position information: Tænd
Power source voltage: 14.5 V
IOD fuse eqipment flag: Tænd
Crash down signal: Sluk
Pre air conditioning signal: Sluk
High voltage ready signal: Tænd
Battery cooling request signal: Sluk
Shut down signal: Tænd
Engine work time: 11950120 sek
System operation time: 201490 min
Ignition switch/Electric motor switch on time: 11983085 sek
Battery cooling time: 552935 sek
Compressor high speed drive time: 35370 sek
Solenoid valve operation counter: 3342 Count
Maximum pressure: 2.04 MPa
High pressure cut times: 0 Count
Compressor drive time: 2755230 sek
Compressor high pressure drive time: 0 sek
Electrical water heater PTC3 drive time: 1157770 sek
Electric water pump: 6528275 sek
High water temperature: 327675 sek
High water temperature cut counter: 0 Count
Maximum coolant temperature: 112 °C
Electrical water heater inlet max temperature: 101 °C
Electrical water heater outlet max temperature: 102 °C
Electrical water heater PTC1 drive time: 1722560 sek
Electrical water heater PTC2 drive time: 1614535 sek
Fan high driving time: 304260 sek
Fan lo driving time: 7581765 sek
Fan M1 driving time: 1298885 sek
Fan M2 driving time: 402325 sek
Udgangs test
Controls
In/out select damper
Air outlet c/o damper
Condenser fan
A/C switch
Rear defogger switch
Electronic water heater test
Solenoid Valve Test
Engine start request
Electric water pump
Front blower fan
Driver air mix damper motor
As air mix damper motor
Muligheder
Controls
Compressor drive history reset
Battery cooling drive history reset
ELC water pump drive his. reset
Heated windscreen test mode
Heated windscreen test mode stop
Electronic water heater test