PKW, MITSUBISHI, PHEV (GG), 2020, GG2W, XDHHZL3M, Electric Heater

Heizer - Electric Heater - 0

Identifikation

Identifikator: 00 00

ECU origin: 04

Lieferantennummer: 65

Steuergerät ID: 00

Diagnoseversion: 00

Hardwareversion: 00 01

Softwareversion: 00 01 01

Ersatzteilnummer: 7820A744

Softwarenummer: FFFFFF

FIN (ursprünglich): --

Class: --

Modell: --

Typ: --

Modelljahr: --

FIN: --

Kalibrierung ID: --

CVN: --

Fehlercode

B10C0: Innenraum-Temperatursensor - Kurzschluss

U0184: Lost communication with audio module

Controls

Fehlercode löschen

Ist-Werte

Heater power: 10200 W

Heater current: 0.0 A

Heater inlet temperature sensor: 215 °C

Heater outlet temperature sensor: -20 °C

Current fail at heater stop: AUS

PTC heater 1: AUS

Temperature sensor faulty: AUS

PTC heater 2: AUS

ECU internal voltage fail: AUS

PTC heater 3: EIN

Heater power restriction: No restriction

PTC heater 4: AUS

IGBT temperature fail: AUS

Circuit board temperature fail: AUS

Heater status: Normal

Short circuit (Overcurrent fail): AUS

Heater circuit fail: AUS

Input voltage fail (High voltage): AUS

High water temperature fail: AUS

Heater drive permission signal: EIN

Heater target water temperature: 128 °C

Heater power upper limit: 10200 W

Heater water temperature adjust value: 215 °C

Kilometerzähler: 420390.8 km

IGBT temperature sensor 1: -40 °C

IGBT temperature sensor 2: -40 °C

IGBT temperature sensor 3: -40 °C

IGBT temperature sensor 4: -40 °C

Circuit board temperature sensor: -40 °C

Input current (High voltage): 51.0 A

Input voltage (High voltage): 437.5 V

Electric heater test result: Normal

PTC heater 3 drive time: 196605 sec

PTC heater 4 drive time: 490 sec

System operation time: 8388608 min

PTC heater 1 drive time: 83886075 sec

PTC heater 2 drive time: 115 sec

PTC heater 4 use times: 12596 times

PTC heater 1 use times: 16777215 times

PTC heater 2 use times: 1619 times

PTC heater 3 use times: 1142 times

IGBT maximum temperature: 195 °C

Maximum current: 35.0 A

Maximum voltage: 305.0 V

Heater inlet maximum: 215 °C

Heater outlet maximum: 215 °C

Stellgliedtest

Controls

PTC heater 1

PTC heater 2

PTC heater 3

PTC heater 4

Dienst­programme

Controls

Electric heater