Bil, MITSUBISHI, PHEV (GG), 2019, GG2W, XDHHZR8, CMU2
HV Batteri - CMU2 - 0
Identifikation
Identificere : 00 06
ECU origin: 04
Supplier number: 85
ECU ID: 00
Diagnose version: 06
Hardware version nummer: 01 02
Softwareversion: 02 01 13
Dele nummer: 8634A049
Software nummer: 8634A04904
VIN no (original): --
Class: --
Model: --
Type: --
Model year: --
Stel nr.: --
Calibration ID: --
Calibration verification number (CVN): --
Fejlkoder
Controls
Clear DTC
Levende Data
Cell 002 voltage: 0.000 V
Cell 003 voltage: 0.000 V
Cell 004 voltage: 0.000 V
Cell 005 voltage: 0.000 V
Cell 006 voltage: 0.000 V
Cell 007 voltage: 0.000 V
Cell 008 voltage: 0.000 V
Module voltage: 0.000 V
Cell total voltage: 0.000 V
Voltage diff. (Module-Total cell): 0.000 V
Cell 001 voltage: 0.000 V
Bat-CAN (Bus off): Normal
EEPROM Fail (failure info read): Normal
EEPROM Fail (Learning data read): Normal
Cell 01 connection terminal: Normal
CAN controller: Normal
Cell 03 connection terminal: Normal
Cell 05 connection terminal: Normal
A/D conversion (Reference VOLT.): Normal
Cell 07 connection terminal: Normal
A/D conversion (Temperature sensor 1): Normal
A/D conversion (Temperature sensor 2): Normal
A/D conversion (Temperature sensor 3): Normal
A/D conversion (Temperature sensor 4): Normal
A/D conversion (Temperature sensor 5): Normal
A/D conversion (Module voltage): Normal
Balancer drive time fail (20h): Normal
EEPROM Fail (failure info read): Normal
Cell monitor IC 01: Normal
Cell monitor IC 05: Normal
Cell monitor IC 02: Normal
Cell monitor IC 06: Normal
Cell monitor IC 03: Normal
Voltage sensor: Normal
Cell monitor IC 04: Normal
Microcomputer reference voltage: Normal
IC reference voltage: Normal
Temperature sensor 4 (open): Normal
Temperature sensor 1 (open): Normal
Temperature sensor 5 (open): Normal
Temperature sensor 2 (open): Normal
Temperature sensor 3 (open): Normal
Temperature sensor 4 (short): Normal
Temperature sensor 1 (short): Normal
Temperature sensor 5 (short): Normal
Temperature sensor 2 (short): Normal
Temperature sensor 3 (short): Normal
Cell 04 voltage underflow: Normal
Cell 01 voltage underflow: Normal
Cell 05 voltage underflow: Normal
Cell 02 voltage underflow: Normal
Cell 06 voltage underflow: Normal
Cell 03 voltage underflow: Normal
Cell 07 voltage underflow: Normal
Cell 08 voltage underflow: Normal
Cell 01 voltage overflow: Normal
Cell 02 voltage overflow: Normal
Cell 03 voltage overflow: Normal
Cell 04 voltage overflow: Normal
Cell 08 voltage overflow: Normal
Cell 05 voltage overflow: Normal
Cell 06 voltage overflow: Normal
Cell 07 voltage overflow: Normal
Temperature sensor 4 underflow: Normal
Temperature sensor 1 underflow: Normal
Temperature sensor 5 underflow: Normal
Temperature sensor 2 underflow: Normal
Temperature sensor 3 underflow: Normal
Temperature sensor 4 overflow: Normal
Temperature sensor 1 overflow: Normal
Temperature sensor 5 overflow: Normal
Temperature sensor 2 overflow: Normal
Temperature sensor 3 overflow: Normal
Muligheder
Controls
EEPROM Fail information