Bil, MITSUBISHI, PHEV (GG), 2018, GG2W, XDPHZR6, BMU

Strøm kilde kontrol - BMU - 0

Identifikation

Identificere : 00 02

ECU origin: 04

Supplier number: 85

ECU ID: 00

Diagnose version: 02

Hardware version nummer: 86 00

Softwareversion: 86 00 04

Dele nummer: 8638A037

Software nummer: 8637A69600

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

P1A4C: OR line voltage

Controls

Clear DTC

Levende Data

Battery Total voltage: 0.0 V

Temperature module max: -70 °C

Maximum temperature module ID: 0

Module minimum temperature: -70 °C

Minimum temperature module ID: 0

Batteristrøm: -400 A

Cell number specification: -

Max internal resistance: 28.0 mOhm

Min internal resistance: 0.0 mOhm

Battery current capacity: 14.2 Ah

Charge state (Control): -5.0 %

Battery remaining capacity: 0.0 Ah

Battery maximum input power: 0.00 kW

Battery maximum output power: 44.50 kW

Battery cell voltage difference maximum: 0.000 V

Target cell voltage: 0.026 V

OR power supply voltage: 17.5 V

Charge state (Display): -5.0 %

IGCT power supply voltage: 17.5 V

Battery cooling fan PWM output: 135 %

Battery cooling fan rotations: 3840 Omdr.

Outside discharge time: 2161 min

Outside discharge integrated cur: 658123 Ah

Battery cell maximum voltage: 0.006 V

Average cell voltage: 65.535 V

Voltage dif. fail judgment MAX: 0.255 V

Internal resistance dif. MAX: 13.5 mOhm

Average internal resistance during charging: 0.0 mOhm

Battery heat system drive active flag: Sluk

Battery heat initial judgement end flag: Sluk

Battery heat system drive stop flag: Sluk

Battery heat system drive comp. flag: Sluk

PTC heater temperature sensor: -50 °C

BMU (sub) temperature sensor: -- °C

Maximum voltage cell ID: 0

Battery cell minimum voltage: 0.000 V

Minimum voltage cell ID: 0

Cell 085 voltage: 0.013 V

Cell 086 voltage: 0.007 V

Cell 087 voltage: 2.815 V

Cell 088 voltage: 0.128 V

Cell 089 voltage: 0.100 V

Cell 004 voltage: 0.017 V

Cell 090 voltage: 0.015 V

Cell 091 voltage: 0.004 V

Cell 096 voltage: 0.012 V

Cell 097 voltage: 0.256 V

Cell 098 voltage: 0.320 V

Cell 099 voltage: 0.055 V

Cell 100 voltage: 0.023 V

Cell 101 voltage: 0.000 V

Cell 102 voltage: 0.000 V

Cell 103 voltage: 0.006 V

Cell 005 voltage: 0.128 V

Cell 108 voltage: 0.005 V

Cell 109 voltage: 0.017 V

Cell 110 voltage: 0.021 V

Cell 111 voltage: 0.005 V

Cell 112 voltage: 0.000 V

Cell 113 voltage: 0.000 V

Cell 114 voltage: 0.000 V

Cell 115 voltage: 0.007 V

Cell 120 voltage: 0.014 V

Cell 121 voltage: 0.010 V

Cell 006 voltage: 0.008 V

Cell 122 voltage: 0.000 V

Cell 123 voltage: 0.000 V

Cell 124 voltage: 0.001 V

Cell 125 voltage: 0.000 V

Cell 126 voltage: 0.001 V

Cell 127 voltage: 0.004 V

Cell 007 voltage: 0.002 V

Cell 012 voltage: 0.020 V

Cell 013 voltage: 0.007 V

Cell 014 voltage: 12.819 V

Cell 015 voltage: 0.017 V

Cell 016 voltage: 0.012 V

Cell 017 voltage: 0.016 V

Cell 000 voltage: 0.015 V

Cell 018 voltage: 0.273 V

Cell 019 voltage: 0.050 V

Cell 024 voltage: 2.102 V

Cell 025 voltage: 0.207 V

Cell 026 voltage: 0.166 V

Cell 027 voltage: 0.019 V

Cell 028 voltage: 0.302 V

Cell 029 voltage: 0.120 V

Cell 030 voltage: 0.016 V

Cell 031 voltage: 0.258 V

Cell 001 voltage: 4.369 V

Cell 036 voltage: 0.272 V

Cell 037 voltage: 30.870 V

Cell 038 voltage: 0.012 V

Cell 039 voltage: 0.012 V

Cell 040 voltage: 0.292 V

Cell 041 voltage: 0.105 V

Cell 042 voltage: 0.073 V

Cell 043 voltage: 0.151 V

Cell 048 voltage: 1.109 V

Cell 049 voltage: 65.535 V

Cell 002 voltage: 8.738 V

Cell 050 voltage: 0.000 V

Cell 051 voltage: 0.006 V

Cell 052 voltage: 0.031 V

Cell 053 voltage: 1.023 V

Cell 054 voltage: 0.162 V

Cell 055 voltage: 0.010 V

Cell 072 voltage: 0.089 V

Cell 073 voltage: 0.010 V

Cell 074 voltage: 0.003 V

Cell 075 voltage: 0.006 V

Cell 003 voltage: 0.819 V

Cell 076 voltage: 0.001 V

Cell 077 voltage: 0.003 V

Cell 078 voltage: 0.029 V

Cell 079 voltage: 0.017 V

Cell 084 voltage: 0.031 V

Module temperature 09: 185 °C

Module temperature 10: -50 °C

Module temperature 12: 153 °C

Module temperature 13: 185 °C

Module temperature 14: 185 °C

Module temperature 15: 185 °C

Module temperature 16: 185 °C

Module temperature 18: 172 °C

Module temperature 19: 185 °C

Module temperature 20: 185 °C

Module temperature 21: 185 °C

Module temperature 22: 185 °C

Module temperature 24: 185 °C

Module temperature 25: -66 °C

Module temperature 26: 185 °C

Module temperature 27: 185 °C

Module temperature 28: 185 °C

Module temperature 36: 185 °C

Module temperature 37: 185 °C

Module temperature 38: -69 °C

Module temperature 00: -46 °C

Module temperature 39: 185 °C

Module temperature 40: 185 °C

Module temperature 42: 185 °C

Module temperature 43: 185 °C

Module temperature 44: -69 °C

Module temperature 45: 58 °C

Module temperature 46: 185 °C

Module temperature 48: 185 °C

Module temperature 49: 185 °C

Module temperature 50: 185 °C

Module temperature 01: 185 °C

Module temperature 51: 185 °C

Module temperature 52: -64 °C

Module temperature 54: 185 °C

Module temperature 55: 185 °C

Module temperature 56: 185 °C

Module temperature 57: 185 °C

Module temperature 58: 185 °C

Module temperature 60: -69 °C

Module temperature 61: 185 °C

Module temperature 62: 185 °C

Module temperature 02: 172 °C

Module temperature 63: 185 °C

Module temperature 64: -53 °C

Module temperature 03: 172 °C

Module temperature 04: -64 °C

Module temperature 06: 185 °C

Module temperature 07: 185 °C

Module temperature 08: 185 °C

Cell 108 Balancer drive: Tænd

Cell 112 Balancer drive: Tænd

Cell 109 Balancer drive: Tænd

Cell 113 Balancer drive: Tænd

Cell 110 Balancer drive: Sluk

Cell 114 Balancer drive: Tænd

Cell 111 Balancer drive: Tænd

Cell 115 Balancer drive: Tænd

Cell 120 Balancer drive: Tænd

Cell 124 Balancer drive: Sluk

Cell 121 Balancer drive: Sluk

Cell 125 Balancer drive: Tænd

Cell 122 Balancer drive: Sluk

Cell 126 Balancer drive: Sluk

Cell 123 Balancer drive: Sluk

Cell 127 Balancer drive: Tænd

Cell 000 Balancer drive: Sluk

Cell 004 Balancer drive: Sluk

Cell 001 Balancer drive: Sluk

Cell 005 Balancer drive: Sluk

Cell 002 Balancer drive: Sluk

Cell 006 Balancer drive: Sluk

Cell 003 Balancer drive: Sluk

Cell 007 Balancer drive: Sluk

Cell 012 Balancer drive: Sluk

Cell 016 Balancer drive: Sluk

Cell 013 Balancer drive: Sluk

Cell 017 Balancer drive: Sluk

Cell 014 Balancer drive: Sluk

Cell 018 Balancer drive: Sluk

Cell 015 Balancer drive: Sluk

Cell 019 Balancer drive: Sluk

Cell 024 Balancer drive: Sluk

Cell 028 Balancer drive: Sluk

Cell 025 Balancer drive: Sluk

Cell 029 Balancer drive: Sluk

Cell 026 Balancer drive: Sluk

Cell 030 Balancer drive: Sluk

Cell 027 Balancer drive: Sluk

Cell 031 Balancer drive: Sluk

Cell 036 Balancer drive: Sluk

Cell 040 Balancer drive: Sluk

Cell 037 Balancer drive: Sluk

Cell 041 Balancer drive: Sluk

Cell 038 Balancer drive: Sluk

Cell 042 Balancer drive: Sluk

Cell 039 Balancer drive: Sluk

Cell 043 Balancer drive: Sluk

Cell 048 Balancer drive: Sluk

Cell 052 Balancer drive: Sluk

Cell 049 Balancer drive: Sluk

Cell 053 Balancer drive: Sluk

Cell 050 Balancer drive: Sluk

Cell 054 Balancer drive: Sluk

Cell 051 Balancer drive: Sluk

Cell 055 Balancer drive: Sluk

Cell 072 Balancer drive: Sluk

Cell 076 Balancer drive: Sluk

Cell 073 Balancer drive: Sluk

Cell 077 Balancer drive: Sluk

Cell 074 Balancer drive: Sluk

Cell 078 Balancer drive: Sluk

Cell 075 Balancer drive: Sluk

Cell 079 Balancer drive: Sluk

Cell 084 Balancer drive: Sluk

Cell 088 Balancer drive: Sluk

Cell 085 Balancer drive: Sluk

Cell 089 Balancer drive: Sluk

Cell 086 Balancer drive: Sluk

Cell 090 Balancer drive: Sluk

Cell 087 Balancer drive: Sluk

Cell 091 Balancer drive: Sluk

Cell 096 Balancer drive: Sluk

Cell 100 Balancer drive: Sluk

Cell 097 Balancer drive: Sluk

Cell 101 Balancer drive: Sluk

Cell 098 Balancer drive: Sluk

Cell 102 Balancer drive: Sluk

Cell 099 Balancer drive: Sluk

Cell 103 Balancer drive: Tænd

Quick charge integrated current: 7 Ah*1000

Sum total time backup: 61 Month

Charge & Discharge integrated current: 123724 Ah

BAT.capa. secular deterioration: 2164260863 %

Battery capacity cycle deterioration: 1075183616 %

Sum total time backup: 2 Month

OBC integrated current value: 32 Ah*1000

Cell current capacity (measured): 6553.5 Ah

Cell current capacity difference: -92.9 Ah

Auto capacity measured result his. 5: 40.0 Ah

Auto capacity measured result his. 6: 40.0 Ah

Auto capacity measured result his. 7: 40.0 Ah

Auto capacity measured result his. 8: 40.0 Ah

Auto capacity measured result his. 9: 40.0 Ah

Auto capacity measured result his. 10: 40.0 Ah

Auto capacity measured result his. 1: 40.0 Ah

Auto capa. measured result his. 2: 40.0 Ah

Auto capacity measured result his. 3: 40.0 Ah

Auto capacity measured result his. 4: 40.0 Ah

Auto capacity measured odometer his. 5: 0 km

Auto capacity measured odometer his. 6: 109 km

Auto capacity measured odometer his. 7: 8192 km

Auto capacity measured odometer his. 8: 1120 km

Auto capacity measured odometer his. 9: 198 km

Auto capacity measured odometer his. 10: 1670 km

Auto capacity measured odometer his. 1: 197024 km

Auto capacity measured odometer his. 2: 13875 km

Auto capacity measured odometer his. 3: 90 km

Auto capacity measured odometer his. 4: 77 km

Capacity measured discharge current: NG/Not performed

Capacity measured (MUT) comp. history: Ikke tilstede

Capacity measured Pre А/С history: Ikke tilstede

Capacity measured charge cancel history: Ikke tilstede

Capacity measured high temperature history: Ikke tilstede

Capacity measured low temperature history: Ikke tilstede

Capacity measured fail history: Ikke tilstede

Udgangs test

Controls

Battery cooling fan PWM

Battery balancer unit

Battery heating system power relay

Muligheder

Controls

CMU support forced release

Control information

Battery capacity estimated information reset

Battery heating system drive

CMU ID numbering

Cell voltage smoothing

Battery auto capacity measured