Bil, MITSUBISHI, PHEV (GG), 2018, GG2W, XDPHZL6, OBC

Strøm kilde kontrol - OBC - 0

Identifikation

Identificere : 00 01

ECU origin: 04

Supplier number: 85

ECU ID: 00

Diagnose version: 01

Hardware version nummer: 86 00

Softwareversion: 86 00 04

Dele nummer: 8638A037

Software nummer: 8637A69600

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

U1120: C-CAN bus line low input

Controls

Clear DTC

Levende Data

Current charge time: 0 min

Accumulated CHG fail stop count: 23 times

DCDC accumulated active count: 13145 times

DCDC accumulated active time: 508885 min

Current DCDC active time: 7 min

DCDC accumulated fail stop count: 0 times

Accumulated CHG count for 100 V: 28 times

Accumulated CHG count for 200 V: 2944 times

Accumulated CHG time for 100 V: 0 min

Accumulated CHG time for 200 V: 300098 min

Voltage target value: 0.0 V

Current target value: 0.0 A

Power supply voltage: 14.5 V

PFC output voltage: 194 V

Pilot signal (Duty ratio): 0 %

PFC temperature: 12 °C

Inverter temperature 1: 10 °C

Inverter temperature 2: 11 °C

Inside temperature: 14 °C

Power supply voltage (CAN): 14.5 V

On board CHG permit (CAN) flag: Sluk

EEPROM write status: Komplet

Motor/Inverter coolant temperature: 9 °C

Charge start-up req. signal (HW): LO

S2 switch: Sluk

Charge flag: Sluk

Charge start-up req. signal (CAN): LO

Abnormal stop flag: Sluk

Cooling request flag: Sluk

Control power supply req. flag: Tænd

Output limit history (Input voltage): No record

PFC start-up flag: Sluk

Input current 0 point check: Not accept

Output limit his. (TEMP. trigger): No record

Control mode: Tomgang

Output limit flag: Sluk

Current input voltage type: No input

Output limit judge (TEMP.): Sluk

Output limit judge (Input voltage): Sluk

Input voltage: 0 V

Input current: 0.0 A

Output voltage: 320 V

Output current: 0.1 A

DCDC power supply voltage: 14.5 V

DCDC inverter temperature 1: 19 °C

DCDC rectification temperature: 13 °C

DCDC inverter temperature 2: 27 °C

DCDC power supply voltage (CAN): 14.5 V

DCDC Motor/Inverter coolant temperature: 9 °C

DCDC drive permission flag: Tænd

DCDC drive flag: Tænd

DCDC fail flag: Sluk

DCDC output volt target value: 14.70 V

DCDC Input voltage: 322 V

DCDC Input current: 1.2 A

DCDC Output voltage(S terminal): 14.7 V

DCDC Output voltage(B terminal): 14.8 V

DCDC Output current: 28 A