Bil, MITSUBISHI, PHEV (GG), 2018, GG2W, XDHHZL3M, Air Conditioner

Klima Anlæg - Air Conditioner - 0

Identifikation

Identificere : 00 01

ECU origin: 04

Supplier number: 65

ECU ID: 00

Diagnose version: 01

Hardware version nummer: 00 01

Softwareversion: 00 01 01

Dele nummer: 7820A744

Software nummer: FFFFFF

VIN no (original): JMBXTGF3WDZ003948

Class: TG

Model: Outlander / GF

Type: GF3W

Model year: 2014

Stel nr.: JMBXTGF3WEZ003948

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

B1115: Electric water pump (EWP) malfunction

Controls

Clear DTC

Levende Data

Interior temperature sensor: 18.0 °C

Air thermo sensor: 27.8 °C

Pressure sensor: 2.24 MPa

Photo sensor: 99.0 W/m2

Motor kølevæske temperatur føler: 82 °C

Ambient temperature sensor: 6.5 °C

Generator use rate: 0 %

Battery cooling air thermo sensor: 7.0 °C

Electrical water heater inlet sensor: 64.0 °C

Electrical water heater outlet sensor: 67.0 °C

Motor Hastighed: 175 Omdr.

Køretøjs hastighed : 77 km/h

Supply power for A/C: 5120 W

High voltage battery current: -325.72 A

High voltage battery voltage: 0.0 V

Driver air mix flap potentiometer: 7 %

Passenger air mix flap potentiometer: 5 %

Air outlet c/o potentiometer: 12 %

In/out select damp potentiometer: 0 %

Front blower fan: 0 steps

Target front blower fan: 0 steps

Air outlet c/o potentiometer (target): DEF

In/out select damp poten (target): Fresh

A/C compressor drive request: Sluk

Air conditioning switch: Sluk

Solenoid valve output: Tænd

Bagrudeafdugningskontakt: Sluk

Condenser fan: 8 %

Engine start request: Sluk

Electrical water heater PTC1 output: Sluk

A/C inverter switch: Sluk

Electrical water heater PTC2 output: Sluk

Electrical water heater PTC3 output: Sluk

Compressor stop eternity: Sluk

Compressor over current: Sluk

Compressor drive status: Normal

Compressor controller fail: Sluk

Compressor sensor fail: Sluk

Compressor heat protection: Sluk

Compressor power fail: Sluk

Compressor voltage fail: Normal

Compressor drive flag (ignition cycle): Sluk

Compressor speed: 0 Omdr.

Compressor: 0 W

Electrical water heater level: 4 steps

Electrical water heater: 3200 W

Electric water pump: 100 %

High pressure fail flag: Tænd

Low pressure fail flag: Tænd

Refrigerant leak (Low pressure): Igang

Refrigerant leak (level 20%): Fejl

Driver seat setting temperature: 67.0 °C

Set temperature (Passenger side): 67.5 °C

Compressor drive history flag: Sluk

Battery cooling drive history flag: Sluk

Electrical water heater test result: Fail

ELC water pump drive his. flag: Sluk

Heated windshield test mode flag: Sluk

Heated windscreen equipment: Ikke tilstede

ECO mode: ECO

Wiper operation flag: Sluk

Ignition/electric motor switch position information: Tænd

Power source voltage: 14.5 V

IOD fuse eqipment flag: Tænd

Crash down signal: Sluk

Pre air conditioning signal: Sluk

High voltage ready signal: Tænd

Battery cooling request signal: Sluk

Shut down signal: Tænd

Engine work time: 11950120 sek

System operation time: 201490 min

Ignition switch/Electric motor switch on time: 11983085 sek

Battery cooling time: 552935 sek

Compressor high speed drive time: 35370 sek

Solenoid valve operation counter: 3342 Count

Maximum pressure: 2.04 MPa

High pressure cut times: 0 Count

Compressor drive time: 2755230 sek

Compressor high pressure drive time: 0 sek

Electrical water heater PTC3 drive time: 1157770 sek

Electric water pump: 6528275 sek

High water temperature: 327675 sek

High water temperature cut counter: 0 Count

Maximum coolant temperature: 112 °C

Electrical water heater inlet max temperature: 101 °C

Electrical water heater outlet max temperature: 102 °C

Electrical water heater PTC1 drive time: 1722560 sek

Electrical water heater PTC2 drive time: 1614535 sek

Fan high driving time: 304260 sek

Fan lo driving time: 7581765 sek

Fan M1 driving time: 1298885 sek

Fan M2 driving time: 402325 sek

Udgangs test

Controls

In/out select damper

Air outlet c/o damper

Condenser fan

A/C switch

Rear defogger switch

Electronic water heater test

Solenoid Valve Test

Engine start request

Electric water pump

Front blower fan

Driver air mix damper motor

As air mix damper motor

Muligheder

Controls

Compressor drive history reset

Battery cooling drive history reset

ELC water pump drive his. reset

Heated windscreen test mode

Heated windscreen test mode stop

Electronic water heater test