Bil, MITSUBISHI, PHEV (GG), 2018, GG2W, XDHHZL3M, CMU8

HV Batteri - CMU8 - 0

Identifikation

Identificere : 00 06

ECU origin: 04

Supplier number: 85

ECU ID: 00

Diagnose version: 06

Hardware version nummer: 01 02

Softwareversion: 02 01 13

Dele nummer: 8634A049

Software nummer: 8634A04904

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

Stel nr.: --

Calibration ID: --

Calibration verification number (CVN): --

Fejlkoder

Controls

Clear DTC

Levende Data

Cell 002 voltage: 0.000 V

Cell 003 voltage: 0.000 V

Cell 004 voltage: 0.000 V

Cell 005 voltage: 0.000 V

Cell 006 voltage: 0.000 V

Cell 007 voltage: 0.000 V

Cell 008 voltage: 0.000 V

Module voltage: 0.000 V

Cell total voltage: 0.000 V

Voltage diff. (Module-Total cell): 0.000 V

Cell 001 voltage: 0.000 V

Bat-CAN (Bus off): Normal

EEPROM Fail (failure info read): Normal

EEPROM Fail (Learning data read): Normal

Cell 01 connection terminal: Normal

CAN controller: Normal

Cell 03 connection terminal: Normal

Cell 05 connection terminal: Normal

A/D conversion (Reference VOLT.): Normal

Cell 07 connection terminal: Normal

A/D conversion (Temperature sensor 1): Normal

A/D conversion (Temperature sensor 2): Normal

A/D conversion (Temperature sensor 3): Normal

A/D conversion (Temperature sensor 4): Normal

A/D conversion (Temperature sensor 5): Normal

A/D conversion (Module voltage): Normal

Balancer drive time fail (20h): Normal

EEPROM Fail (failure info read): Normal

Cell monitor IC 01: Normal

Cell monitor IC 05: Normal

Cell monitor IC 02: Normal

Cell monitor IC 06: Normal

Cell monitor IC 03: Normal

Voltage sensor: Normal

Cell monitor IC 04: Normal

Microcomputer reference voltage: Normal

IC reference voltage: Normal

Temperature sensor 4 (open): Normal

Temperature sensor 1 (open): Normal

Temperature sensor 5 (open): Normal

Temperature sensor 2 (open): Normal

Temperature sensor 3 (open): Normal

Temperature sensor 4 (short): Normal

Temperature sensor 1 (short): Normal

Temperature sensor 5 (short): Normal

Temperature sensor 2 (short): Normal

Temperature sensor 3 (short): Normal

Cell 04 voltage underflow: Normal

Cell 01 voltage underflow: Normal

Cell 05 voltage underflow: Normal

Cell 02 voltage underflow: Normal

Cell 06 voltage underflow: Normal

Cell 03 voltage underflow: Normal

Cell 07 voltage underflow: Normal

Cell 08 voltage underflow: Normal

Cell 01 voltage overflow: Normal

Cell 02 voltage overflow: Normal

Cell 03 voltage overflow: Normal

Cell 04 voltage overflow: Normal

Cell 08 voltage overflow: Normal

Cell 05 voltage overflow: Normal

Cell 06 voltage overflow: Normal

Cell 07 voltage overflow: Normal

Temperature sensor 4 underflow: Normal

Temperature sensor 1 underflow: Normal

Temperature sensor 5 underflow: Normal

Temperature sensor 2 underflow: Normal

Temperature sensor 3 underflow: Normal

Temperature sensor 4 overflow: Normal

Temperature sensor 1 overflow: Normal

Temperature sensor 5 overflow: Normal

Temperature sensor 2 overflow: Normal

Temperature sensor 3 overflow: Normal

Muligheder

Controls

EEPROM Fail information